SwePub
Sök i SwePub databas

  Utökad sökning

AND är defaultoperator och kan utelämnas

Träfflista för sökning "hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) srt2:(2000-2009)"

Sökning: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) > (2000-2009)

  • Resultat 1-10 av 971
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Eklund, Anders, 1965-, et al. (författare)
  • A resonator sensor for measurement of intraocular pressure : evaluation in an in vitro pig-eye model
  • 2000
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 21:3, s. 355-367
  • Tidskriftsartikel (refereegranskat)abstract
    • Intraocular pressure (IOP) measurement is performed routinely at every eye clinic. High IOP, which can be a sign of glaucoma, can lead to degeneration of the retina and can cause blindness. In this study we developed a resonator sensor for IOP measurement based on an oscillator consisting of a piezoelectric element made of lead zirconate titanate, a flat contact piece of nylon and a feedback circuit. The aim of this study was to evaluate the new sensor's ability to determine lOP in an in vitro pig-eye model. Six eyes from four pigs were removed and fixed in agar. They were then pressurized by a saline column (10-35 cm H2O) through a cannula inserted into the vitreous chamber. The IOP was measured with the resonator sensor applied to cornea. An Alcon applanation pneumatonometer and a standard Viggo-Spectramed pressure sensor connected to the saline column were used as references. The IOP as measured with the resonator sensor correlated well with the pressure elicited by the saline column for individual eyes (r = 0.96-0.99, n = 60) and for all eyes (r = 0.92, n = 360). The correlation between the resonance sensor and the pneumatonometer was r = 0.92 (n = 360). The pneumatonometer also showed a good correlation with the saline column (r = 0.98, n = 360). We conclude that our in vitro pig-eye model made it possible to induce reproducible variation in IOP, and measurement of that pressure with the newly developed resonator sensor gave very promising results for development of a clinically applicable IOP tonometer with unique properties.
  •  
2.
  • Pau, Ivan, et al. (författare)
  • Home e-health system integration in the Smart Home through a common media server.
  • 2009
  • Ingår i: EMBC: 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20. - 9781424432967 ; 2009, s. 6171-4
  • Konferensbidrag (refereegranskat)abstract
    • Home e-health systems and services are revealed as one of the most important challenges to promote Quality of Life related to Health in the Information Society. Leading companies have worked on e-health systems although the majority of them are addressed to hospital or primary care settings. The solution detailed in this paper offers a personal health system to be integrated with Smart Home services platform to support home based e-care. Thus, the home e-health system and architecture detailed in this research work is ready to supply a seamless personal care solution both from the biomedical data analysis, service provision, security guarantee and information management s point of view. The solution is ready to be integrated within the Accessible Digital Home, a living lab managed by Universidad Politécnica de Madrid for R&D activities.
  •  
3.
  • Augustine, Robin (författare)
  • Biocompatibility study of hydroxyapatite-chitosan composite for medical applications at microwave frequencies
  • 2008
  • Ingår i: Microwave and optical technology letters (Print). - 0895-2477 .- 1098-2760. ; 50:11, s. 2931-2934
  • Tidskriftsartikel (refereegranskat)abstract
    • Hydroxyapatite (HAp, Ca10(PO4)6(OH)2) bioceramic and chitosan (poly [(β-1-4) d-glucosamine]) biopolymer show good biocompatibility in vivo. They have biological origin and show excellent interactions with microwave. Microwave study of HAp made using different drying techniques and their composites with chitosan in the ISM band is presented. Pastes are made using HAp and chitosan with different ratios of mixing. The dielectric properties of this composites match with that of human fat, collagen tissues. Some of the compositions exhibit dielectric property close to that of natural bone. This makes them more biocompatible and better substitutes for natural bone. Thus composite bioceramics can be considered as phantom model constituents for imaging purposes.
  •  
4.
  • Candefjord, Stefan, et al. (författare)
  • Evaluating the use of a Raman fiberoptic probe in conjunction with a resonance sensor for measuring porcine tissue in vitro
  • 2009
  • Ingår i: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering. - Heidelberg : Springer. ; , s. 414-417, s. 414-417
  • Konferensbidrag (refereegranskat)abstract
    • Prostate cancer is the most common form of cancer and is the third leading cause of cancer-related death in European men. There is a need for new methods that can accurately localize and diagnose prostate cancer. In this study a new approach is presented: a combination of resonance sensor technology and Raman spectroscopy. Both methods have shown promising results for prostate cancer detection in vitro. The aim of this study was to evaluate the combined information from measurements with a Raman fiberoptic probe and a resonance sensor system. Pork belly tissue was used as a model system. A three-dimensional translation table was equipped with an in-house developed software, allowing measurements to be performed at the same point using two separate instruments. The Raman data was analyzed using principal component analysis and hierarchical clustering analysis. The spectra were divided into 5 distinct groups. The mean stiffness of each group was calculated from the resonance sensor measurements. One of the groups differed significantly (p < 0.05) from the others. A regression analysis, with the stiffness parameter as response variable and the principal component scores of the Raman data as the predictor variables, explained 67% of the total variability. The use of a smaller resonance sensor tip would probably increase the degree of correlation. In conclusion, Raman spectroscopy provides additional discriminatory power to the resonance sensor.
  •  
5.
  • Eklund, Anders, et al. (författare)
  • Evaluation of applanation resonator sensors for intra-ocular pressure measurement : results from clinical and in vitro studies.
  • 2003
  • Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 41:2, s. 190-197
  • Tidskriftsartikel (refereegranskat)abstract
    • Glaucoma is an eye disease that, in its most common form, is characterised by high intra-ocular pressure (IOP), reduced visual field and optic nerve damage. For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring IOP. Recently, an applanation resonator sensor (ARS) for measuring IOP was introduced and evaluated using an in vitro pig-eye model. In the present study, the first clinical evaluation of the same probe has been carried out, with experiments in vivo on human eyes. There was a low but significant correlation between IOP(ARS) and the IOP measured with a Goldmann applanation tonometer (r = 0.40, p = 0.001, n = 72). However, off-centre positioning of the sensor against the cornea caused a non-negligible source of error. The sensor probe was redesigned to have a spherical, instead of flat, contact surface against the eye and was evaluated in the in vitro model. The new probe showed reduced sensitivity to off-centre positioning, with a decrease in relative deviation from 89% to 11% (1 mm radius). For normalised data, linear regression between IOP(ARS) and direct IOP measurement in the vitreous chamber showed a correlation of r = 0.97 (p < 0.001, n = 108) and a standard deviation for the residuals of SD < or = 2.18 mm Hg (n = 108). It was concluded that a spherical contact surface should be preferred and that further development towards a clinical instrument should focus on probe design and signal analysis.
  •  
6.
  •  
7.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Explanatory models for a tactile resonance sensor system-elastic and density-related variations of prostate tissue in vitro
  • 2008
  • Ingår i: Physiological Measurement. - Bristol : IOP Publ. Ltd. - 0967-3334 .- 1361-6579. ; 29:7, s. 729-745
  • Tidskriftsartikel (refereegranskat)abstract
    • Tactile sensors based on piezoelectric resonance have been adopted for medical applications. The sensor consists of an oscillating piezoelectric sensor–circuit system, and a change in resonance frequency is observed when the sensor tip contacts a measured object such as tissue. The frequency change at a constant applied force or mass load is used as a stiffness-sensitive parameter in many applications. Differential relations between force and frequency have also been used for monitoring intraocular pressure and stiffness variations in prostate tissue in vitro. The aim of this study was to relate the frequency change (Δf), measured force (F) and the material properties, density and elasticity to an explanatory model for the resonance sensor measurement principle and thereby to give explanatory models for the stiffness parameters used previously. Simulations of theoretical equations were performed to investigate the relation between frequency change and contact impedance. Measurements with a resonance sensor system on prostate tissue in vitro were used for experimental validation of the theory. Tissue content was quantified with a microscopic-based morphometrical method. Simulation results showed that the frequency change was dependent upon density (ρ) and contact area (S) according to Δf ∝ ρS3/2. The experiments followed the simulated theory at small impression depths. The measured contact force followed a theoretical model with the dependence of the elastic modulus (E) and contact area, F ∝ ES3/2. Measured density variations related to histological variations were statistically weak or non-significant. Elastic variations were statistically significant with contributions from stroma and cancer relative to normal glandular tissue. The theoretical models of frequency change and force were related through the contact area, and a material-dependent explanatory model was found as Δf ∝ ρE−1F. It explains the measurement principle and the previously established stiffness parameters from the material properties point of view.
  •  
8.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Instrument towards faster diagnosis and treatment of prostate cancer : Resonance sensor stiffness measurements on human prostate tissue in vitro
  • 2009
  • Ingår i: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering. - Heidelberg : Springer. ; , s. 145-148, s. 145-148
  • Konferensbidrag (refereegranskat)abstract
    • Prostate cancer is the most common cancer among men and the methods used to detect and diagnose prostate cancer are not sufficiently accurate. Radical prostatectomy is a surgical treatment of prostate cancer where the whole prostate is removed from the patient. Prostate tissue stiffness can be measured with a stiffness sensitive resonance sensor. The aim of this study was to measure the stiffness on the anterior and posterior side of fresh human prostate tissue in vitro and compare these two groups with each other and relate the findings with the prostate tissue histology.  In a prostate tissue slice with mostly normal healthy tissue, the anterior side was significantly harder (p-value < 0.05) as expected. In a prostate tissue slice with areas of cancer tumors, no difference was found between the anterior and posterior sides. However, large stiffness variations were found within groups with measurements points on cancer tissue (coefficient of variation, CV = 42 and 85%), as opposed to groups without cancer tissue (CV = 27 and 28%).  The large stiffness variations could be used as a sign for the presence of cancer. The results are promising for the development of an instrument and method for faster diagnosis on radical prostatectomy samples.
  •  
9.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Prostate tissue stiffness as measured with a resonance sensor system : a study on silicone and human prostate tissue in vitro.
  • 2006
  • Ingår i: Medical and Biological Engineering and Computing. - : Springer Science and Business Media LLC. - 0140-0118 .- 1741-0444. ; 44:7, s. 593-603
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common form of cancer in men in Europe and in the USA. Some prostate tumours are stiffer than the surrounding normal tissue, and it could therefore be of interest to measure prostate tissue stiffness. Resonance sensor technology based on piezoelectric resonance detects variations in tissue stiffness due to a change in the resonance frequency. An impression-controlled resonance sensor system was used to detect stiffness in silicone rubber and in human prostate tissue in vitro using two parameters, both combinations of frequency change and force. Variations in silicone rubber stiffness due to the mixing ratio of the two components could be detected (p<0.05) using both parameters. Measurements on prostate tissue showed that there existed a statistically significant (MANOVA test, p<0.001) reproducible difference between tumour tissue (n=13) and normal healthy tissue (n=98) when studying a multivariate parameter set. Both the tumour tissue and normal tissue groups had variations within them, which were assumed to be related to differences in tissue composition. Other sources of error could be uneven surfaces and different levels of dehydration for the prostates. Our results indicated that the resonance sensor could be used to detect stiffness variations in silicone and in human prostate tissue in vitro. This is promising for the development of a future diagnostic tool for prostate cancer.
  •  
10.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Resonance sensor measurements of stiffness variations in prostate tissue in vitro : a weighted tissue proportion model
  • 2006
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 27:12, s. 1373-86
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common type of cancer in men in Europe and the US. The methods to detect prostate cancer are still precarious and new techniques are needed. A piezoelectric transducer element in a feedback system is set to vibrate with its resonance frequency. When the sensor element contacts an object a change in the resonance frequency is observed, and this feature has been utilized in sensor systems to describe physical properties of different objects. For medical applications it has been used to measure stiffness variations due to various patho-physiological conditions. In this study the sensor's ability to measure the stiffness of prostate tissue, from two excised prostatectomy specimens in vitro, was analysed. The specimens were also subjected to morphometric measurements, and the sensor parameter was compared with the morphology of the tissue with linear regression. In the probe impression interval 0.5-1.7 mm, the maximum R(2) > or = 0.60 (p < 0.05, n = 75). An increase in the proportion of prostate stones (corpora amylacea), stroma, or cancer in relation to healthy glandular tissue increased the measured stiffness. Cancer and stroma had the greatest effect on the measured stiffness. The deeper the sensor was pressed, the greater, i.e., deeper, volume it sensed. Tissue sections deeper in the tissue were assigned a lower mathematical weighting than sections closer to the sensor probe. It is concluded that cancer increases the measured stiffness as compared with healthy glandular tissue, but areas with predominantly stroma or many stones could be more difficult to differ from cancer.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 971
Typ av publikation
konferensbidrag (441)
tidskriftsartikel (375)
doktorsavhandling (49)
patent (32)
bokkapitel (26)
licentiatavhandling (23)
visa fler...
rapport (11)
forskningsöversikt (5)
annan publikation (4)
samlingsverk (redaktörskap) (2)
bok (2)
proceedings (redaktörskap) (1)
visa färre...
Typ av innehåll
refereegranskat (663)
övrigt vetenskapligt/konstnärligt (270)
populärvet., debatt m.m. (38)
Författare/redaktör
Laurell, Thomas (125)
Marko-Varga, György (58)
Lindahl, Olof (55)
Nilsson, Johan (48)
Lindecrantz, Kaj, 19 ... (34)
Kleiven, Svein, 1966 ... (30)
visa fler...
Ramser, Kerstin (29)
Sörnmo, Leif (24)
Hallberg, Josef (24)
Almqvist, Monica (23)
Persson, Mikael, 195 ... (23)
Brodin, Lars-Åke (23)
Eklund, Anders (22)
Osvalder, Anna-Lisa, ... (21)
Ressine, Anton (20)
Seoane, Fernando, 19 ... (18)
Synnes, Kåre (18)
Vegvari, Akos (17)
Frimmel, Hans (17)
Persson, Hans W (17)
Evander, Mikael (17)
Båth, Magnus, 1974 (16)
Lenshof, Andreas (16)
Wallman, Lars (15)
Ekström, Simon (15)
Hult, Peter, 1964- (15)
Jansson, Tomas (15)
Bligård, Lars-Ola, 1 ... (15)
Månsson, Lars Gunnar ... (15)
Petersson, Filip (15)
Lindecrantz, Kaj (14)
Bergh, Anders (14)
Kjellmer, Ingemar, 1 ... (14)
Bengtsson, Martin (14)
Mehnert, Andrew, 196 ... (14)
Lindström, Kjell (14)
Wårdell, Karin (14)
Bjällmark, Anna (14)
von Holst, Hans (12)
Lindén, Maria (12)
Knutsson, Hans (12)
Thordstein, Magnus (12)
Gustafsson, Agnetha, ... (12)
Seoane Martinez, Fer ... (12)
Helms, Gunther (11)
Ljungberg, Börje (11)
Danielsson, Mats, Pr ... (11)
Löfgren, Nils, 1969 (11)
Cederström, Björn (11)
Fhager, Andreas, 197 ... (11)
visa färre...
Lärosäte
Lunds universitet (247)
Kungliga Tekniska Högskolan (233)
Chalmers tekniska högskola (159)
Linköpings universitet (144)
Luleå tekniska universitet (114)
Göteborgs universitet (61)
visa fler...
Umeå universitet (58)
Uppsala universitet (54)
Karolinska Institutet (41)
Mälardalens universitet (23)
Högskolan i Borås (23)
Jönköping University (17)
Linnéuniversitetet (12)
Stockholms universitet (9)
Högskolan i Halmstad (8)
Örebro universitet (7)
Sveriges Lantbruksuniversitet (5)
Gymnastik- och idrottshögskolan (4)
VTI - Statens väg- och transportforskningsinstitut (2)
Högskolan i Gävle (1)
Malmö universitet (1)
Mittuniversitetet (1)
RISE (1)
Högskolan Dalarna (1)
Blekinge Tekniska Högskola (1)
Kungl. Musikhögskolan (1)
visa färre...
Språk
Engelska (900)
Svenska (68)
Tyska (1)
Japanska (1)
Kinesiska (1)
Forskningsämne (UKÄ/SCB)
Teknik (970)
Naturvetenskap (188)
Medicin och hälsovetenskap (160)
Samhällsvetenskap (18)
Humaniora (4)
Lantbruksvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy