SwePub
Sök i SwePub databas

  Utökad sökning

AND är defaultoperator och kan utelämnas

Träfflista för sökning "hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Other Medical Engineering) srt2:(2010-2019)"

Sökning: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Other Medical Engineering) > (2010-2019)

  • Resultat 1-10 av 506
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brown, Shannon, et al. (författare)
  • Intarsia-sensorized band and textrodes for real-time myoelectric pattern recognition
  • 2016
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2016 IEEE 38th Annual International Conference of the. - : Institute of Electrical and Electronics Engineers (IEEE). - 1557-170X. - 9781457702204 ; , s. 6074-6077
  • Konferensbidrag (refereegranskat)abstract
    • Surface Electromyography (sEMG) has applications in prosthetics, diagnostics and neuromuscular rehabilitation. Self-adhesive Ag/AgCl are the electrodes preferentially used to capture sEMG in short-term studies, however their long-term application is limited. In this study we designed and evaluated a fully integrated smart textile band with electrical connecting tracks knitted with intarsia techniques and knitted textile electrodes. Real-time myoelectric pattern recognition for motor volition and signal-to-noise ratio (SNR) were used to compare its sensing performance versus the conventional Ag-AgCl electrodes. After a comprehending measurement and performance comparison of the sEMG recordings, no significant differences were found between the textile and the Ag-AgCl electrodes in SNR and prediction accuracy obtained from pattern recognition classifiers.
  •  
2.
  • Hafid, Abdelakram, et al. (författare)
  • Full Impedance Cardiography Measurement Device Using Raspberry PI3 and System-on-Chip Biomedical Instrumentation Solutions
  • 2018
  • Ingår i: IEEE journal of biomedical and health informatics. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 2168-2194 .- 2168-2208. ; 22:6, s. 1883-1894
  • Tidskriftsartikel (refereegranskat)abstract
    • Impedance cardiography (ICG) is a noninvasive method for monitoring cardiac dynamics using electrical bioimpedance (EBI) measurements. Since its appearance more than 40 years ago, ICG has been used for assessing hemodynamic parameters. This paper presents a measurement system based on two System on Chip (SoC) solutions and Raspberry PI, implementing both a full three-lead ECG recorder and an impedance cardiographer, for educational and research development purposes. Raspberry PI is a platform supporting Do-I t-Yourself project and education applications across the world. The development is part of Biosignal PI, an open hardware platform focusing in quick prototyping of physiological measurement instrumentation. The SoC used for sensing cardiac biopotential is the ADAS1000, and for the EBI measurement is the AD5933. The recordings were wirelessly transmitted through Bluetooth to a PC, where the waveforms were displayed, and hemodynamic parameters such as heart rate, stroke volume, ejection time and cardiac output were extracted from the ICG and ECG recordings. These results show how Raspberry PI can be used for quick prototyping using relatively widely available and affordable components, for supporting developers in research and engineering education. The design and development documents will be available on www.BiosignalPl.com, for open access under a Non Commercial-Share A like 4.0 International License.
  •  
3.
  • Seoane, Fernando, 1976-, et al. (författare)
  • Textile-Friendly Interconnection between Wearable Measurement Instrumentation and Sensorized Garments-Initial Performance Evaluation for Electrocardiogram Recordings.
  • 2019
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 19:20
  • Tidskriftsartikel (refereegranskat)abstract
    • The interconnection between hard electronics and soft textiles remains a noteworthy challenge in regard to the mass production of textile-electronic integrated products such as sensorized garments. The current solutions for this challenge usually have problems with size, flexibility, cost, or complexity of assembly. In this paper, we present a solution with a stretchable and conductive carbon nanotube (CNT)-based paste for screen printing on a textile substrate to produce interconnectors between electronic instrumentation and a sensorized garment. The prototype connectors were evaluated via electrocardiogram (ECG) recordings using a sensorized textile with integrated textile electrodes. The ECG recordings obtained using the connectors were evaluated for signal quality and heart rate detection performance in comparison to ECG recordings obtained with standard pre-gelled Ag/AgCl electrodes and direct cable connection to the ECG amplifier. The results suggest that the ECG recordings obtained with the CNT paste connector are of equivalent quality to those recorded using a silver paste connector or a direct cable and are suitable for the purpose of heart rate detection.
  •  
4.
  • Ortiz Catalan, Max Jair, 1982, et al. (författare)
  • Patterned Stimulation of Peripheral Nerves Produces Natural Sensations With Regards to Location but Not Quality
  • 2019
  • Ingår i: IEEE Transactions on Medical Robotics and Bionics. - 2576-3202. ; 1:3, s. 199-203
  • Tidskriftsartikel (refereegranskat)abstract
    • Sensory feedback is crucial for dexterous manipulation and sense of ownership. Electrical stimulation of severed afferent fibers due to an amputation elicits referred sensations in the missing limb. However, these sensations are commonly reported with a concurrent “electric” or “tingling” character (paresthesia). In this paper, we examined the effect of modulating different pulse parameters on the quality of perceived sensations. Three subjects with above-elbow amputation were implanted with cuff electrodes and stimulated with a train of pulses modulated in either amplitude, width, or frequency (“patterned stimulation”). Pulses were shaped using a slower carrier wave or via quasi-random generation. Subjects were asked to evaluate the natural quality of the resulting sensations using a numeric rating scale. We found that the location of the percepts was distally referred and somatotopically congruent, but their quality remained largely perceived as artificial despite employing patterned modulation. Sensations perceived as arising from the missing limb are intuitive and natural with respect to their location and, therefore, useful for functional restoration. However, our results indicate that sensory transformation from paresthesia to natural qualia seems to require more than patterned stimulation.
  •  
5.
  • Capece, Sabrina, et al. (författare)
  • A general strategy for obtaining biodegradable polymer shelled microbubbles as theranostic devices
  • 2013
  • Ingår i: Chemical Communications. - 1359-7345 .- 1364-548X. ; 49:51, s. 5763-5765
  • Tidskriftsartikel (refereegranskat)abstract
    • Fabrication of multifunctional ultrasound contrast agents (UCAs) has been recently addressed by several research groups. A versatile strategy for the synthesis of UCA precursors in the form of biodegradable vesicles with a biocompatible crosslinked polymer shell is described. Upon ultrasound irradiation, acoustic droplet vaporization transforms such particles into microbubbles behaving as UCAs. This proof of concept entails the features of a potential theranostic microdevice.
  •  
6.
  • Lui, Hoi-Shun, et al. (författare)
  • On the matching medium for microwave stroke diagnosis
  • 2019
  • Ingår i: Biomedical Physics and Engineering Express. - : IOP Publishing. - 2057-1976. ; 5:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The choice of matching medium can directly affect the amount of power transmitted into and through human bodies, which impacts on the quality of the reconstructed images in microwave-based medical imaging, and thus the diagnosis accuracies. In this paper, the amount of the transmitted and reflected power of multi-layer planar healthy and hemorrhagic stroke brain models under different choices of matching medium are determined. These multi-layer planar brain tissue models are made up of at least 17 tissue layers with realistic dielectric properties. A layer of blood with different thickness is introduced to model the case of hemorrhagic stroke. Our results show that matching medium with low relative permittivity provides better intrinsic contrast between healthy brain and hemorrhagic brain. Analysis on how the reflection coefficient and transmittance vary under different matching medium are included to provide better insights to the findings.
  •  
7.
  • Rezaei Aghdam, Sina, 1989, et al. (författare)
  • Reducing Motion Artifacts in Microwave-Based Hemorrhagic Stroke Detection
  • 2019
  • Ingår i: 13th European Conference on Antennas and Propagation, EuCAP 2019.
  • Konferensbidrag (refereegranskat)abstract
    • The use of microwave technology for brain stroke detection opens up the opportunity for developing low-cost transportable devices which can be employed for rapid and prehospital detection of bleeding in patients with traumatic brain injury. Since the detection relies on changes in the scattering parameters of the tissues during pathological conditions, the movements in head or the antennas can deteriorate the detection accuracy. As a countermeasure to this problem, we introduce a technique for reducing the sensitivity of the detection system to motion artifacts. Via analyzing the scattering from an anatomically accurate model of human brain, we evidence that the channels between different pairs of antennas exhibit significantly different levels of sensitivity to the movement. Using this as a ground truth, we develop a generalized singular value decomposition (GSVD)-based approach for assigning appropriate weights to the channels between different antennas such that the probability of correct bleeding detection is maximized.
  •  
8.
  • Tomasic, Ivan, et al. (författare)
  • Comparison of publicly available beat detection algorithms performances on the ECGs obtained by a patch ECG device
  • 2019
  • Ingår i: 2019 42nd International Convention on Information and Communication Technology, Electronics and Microelectronics, MIPRO 2019 - Proceedings. - : Institute of Electrical and Electronics Engineers Inc.. - 9789532330984 ; , s. 275-278
  • Konferensbidrag (refereegranskat)abstract
    • Eight ECG beat detection algorithms, from the PhysioNet's WFDB and Cardiovascular Signal toolboxes, were tested on twenty measurements, obtained by the Savvy patch ECG device, for their accuracy in beat detection. On each subject, one measurement is obtained while sitting and one while running. Each measurement lasted from thirty seconds to one minute. The measurements obtained while running were more challenging for all the algorithms, as most of them almost perfectly detected all the beats on the measurements obtained in sitting position. However, when applied on the measurements obtained while running, all the algorithms have performed with decreased accuracy. Considering overall percentage of the faulty detected peaks, the four best algorithms were jqrs, from the Cardiovascular Signal Toolbox, and ecgpuwave, gqrs, and wqrs, from the WFDB Toolbox, with percentages of faulty detected beats 1.7, 2.3, 2.9, and 3, respectively. 
  •  
9.
  •  
10.
  • Molin, Jesper, 1987, et al. (författare)
  • Slide navigation patterns among pathologists with long experience of digital review
  • 2015
  • Ingår i: Histopathology. - : Wiley. - 0309-0167 .- 1365-2559. ; 67:2, s. 185-192
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: In order to develop efficient digital pathologyworkstations, we studied the navigation patterns ofpathologists diagnosing whole-slide images. To gain abetter understanding of these patterns, we built aconceptual model based on observations. We alsodetermined whether or not new navigation patternshave emerged among pathologists with extensive digitalexperience.Methods and results: Five pathologists were asked todiagnose a set of four cases while thinking out loud.The navigation within the digital slides was recordedand divided into re-occurring navigation actions. Thepathologists reused the same type of actions, but theiroccurrence differed. The most common action was aslow panning that followed an edge structure orcovered an area systematically, which accounted for30.2% of all actions and had a median duration of7.2 s. Of all the actions, 49% were carried out withinthe navigation overview and 38% of the actionscould not have been performed with a conventionalmicroscope.Conclusions: The new navigation possibilities in thedigital workstation were used to a large extent. Thedivision of actions into different concepts can be usedto find and prioritize between existing user interfacedesigns as well as to understand the different navigationstyles used by different pathologists.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 506
Typ av publikation
konferensbidrag (231)
tidskriftsartikel (204)
doktorsavhandling (28)
bokkapitel (21)
licentiatavhandling (11)
forskningsöversikt (6)
visa fler...
rapport (2)
patent (2)
recension (1)
visa färre...
Typ av innehåll
refereegranskat (382)
övrigt vetenskapligt/konstnärligt (119)
populärvet., debatt m.m. (5)
Författare/redaktör
Wårdell, Karin (35)
Kleiven, Svein, 1966 ... (21)
Ramser, Kerstin (21)
Lindahl, Olof (17)
Ortiz Catalan, Max J ... (13)
Persson, Mikael, 195 ... (13)
visa fler...
Davidsson, Johan, 19 ... (12)
Seoane, Fernando, 19 ... (11)
Alrifaiy, Ahmed (11)
Hallberg, Josef (11)
Brolin, Karin, 1974 (11)
Richter, Johan (11)
Dobsicek Trefna, Han ... (11)
Pipkorn, Bengt, 1963 (10)
Abtahi, Farhad, 1981 ... (9)
Cornet, Ronald (9)
Åström, Mattias (8)
Iraeus, Johan, 1973 (8)
Halldin, Peter (7)
Lindecrantz, Kaj (7)
Seoane, Fernando (7)
Lundström, Claes, 19 ... (7)
Håkansson, Bo, 1953 (7)
Mastinu, Enzo, 1987 (6)
Karlsson, Daniel (6)
Wårdell, Karin, 1959 ... (6)
Bitaraf, Nazanin (6)
Olafsdottir, Jóna Ma ... (6)
Candefjord, Stefan, ... (6)
Höglund, Odd (5)
Persson, Anders (5)
Alonso, Fabiola, 198 ... (5)
Malesevic, Nebojsa (5)
Reinfeldt, Sabine, 1 ... (5)
Östh, Jonas, 1983 (5)
Westin, Jerker (4)
Nyholm, Dag (4)
Hallbeck, Martin (4)
Mridha, Mannan (4)
Persson, Cecilia (4)
Öhman-Mägi, Caroline (4)
Sörnmo, Leif (4)
Alonso, Fabiola (4)
Latorre, Malcolm (4)
Zsigmond, Peter (4)
Hemm-Ode, Simone (4)
Magnusson, Charlotte (4)
Svensson, Mats, 1960 (4)
Synnes, Kåre (4)
Lundström, Ronnie (4)
visa färre...
Lärosäte
Chalmers tekniska högskola (125)
Kungliga Tekniska Högskolan (114)
Linköpings universitet (113)
Lunds universitet (48)
Luleå tekniska universitet (47)
Uppsala universitet (30)
visa fler...
Karolinska Institutet (30)
Göteborgs universitet (27)
Linnéuniversitetet (25)
Umeå universitet (24)
Högskolan i Borås (17)
Högskolan i Halmstad (11)
Örebro universitet (11)
RISE (11)
Mälardalens universitet (9)
Jönköping University (7)
Högskolan Dalarna (7)
Sveriges Lantbruksuniversitet (7)
Blekinge Tekniska Högskola (5)
Stockholms universitet (4)
VTI - Statens väg- och transportforskningsinstitut (3)
Malmö universitet (2)
Mittuniversitetet (2)
Högskolan i Skövde (2)
Gymnastik- och idrottshögskolan (1)
Karlstads universitet (1)
visa färre...
Språk
Engelska (487)
Svenska (16)
Spanska (1)
Nederländska (1)
Kinesiska (1)
Forskningsämne (UKÄ/SCB)
Teknik (505)
Medicin och hälsovetenskap (108)
Naturvetenskap (69)
Samhällsvetenskap (11)
Humaniora (4)
Lantbruksvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy