SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk laboratorie och mätteknik) srt2:(2020-2024)"

Sökning: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk laboratorie och mätteknik) > (2020-2024)

  • Resultat 1-10 av 265
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Zeng, Xuezhi, 1980, et al. (författare)
  • Investigation of an ultra wideband noise sensor for health monitoring
  • 2020
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 20:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Quick on-scene assessment and early intervention is the key to reduce the mortality of stroke and trauma patients, and it is highly desirable to develop ambulance-based diagnostic and monitoring devices in order to provide additional support to the medical personnel. We developed a compact and low cost ultra wideband noise sensor for medical diagnostics and vital sign monitoring in pre-hospital settings. In this work, we demonstrated the functionality of the sensor for respiration and heartbeat monitoring. In the test, metronome was used to manipulate the breathing pattern and the heartbeat rate reference was obtained with a commercial electrocardiogram (ECG) device. With seventeen tests performed for respiration rate detection, sixteen of them were successfully detected. The results also show that it is possible to detect the heartbeat rate accurately with the developed sensor.
  •  
2.
  • Abayazid, Fady, et al. (författare)
  • A New Assessment of Bicycle Helmets: The Brain Injury Mitigation Effects of New Technologies in Oblique Impacts
  • 2021
  • Ingår i: Annals of Biomedical Engineering. - : Springer Science and Business Media LLC. - 1573-9686 .- 0090-6964. ; 49:10, s. 2716-2733
  • Tidskriftsartikel (refereegranskat)abstract
    • New helmet technologies have been developed to improve the mitigation of traumatic brain injury (TBI) in bicycle accidents. However, their effectiveness under oblique impacts, which produce more strains in the brain in comparison with vertical impacts adopted by helmet standards, is still unclear. Here we used a new method to assess the brain injury prevention effects of 27 bicycle helmets in oblique impacts, including helmets fitted with a friction-reducing layer (MIPS), a shearing pad (SPIN), a wavy cellular liner (WaveCel), an airbag helmet (Hövding) and a number of conventional helmets. We tested whether helmets fitted with the new technologies can provide better brain protection than conventional helmets. Each helmeted headform was dropped onto a 45° inclined anvil at 6.3 m/s at three locations, with each impact location producing a dominant head rotation about one anatomical axes of the head. A detailed computational model of TBI was used to determine strain distribution across the brain and in key anatomical regions, the corpus callosum and sulci. Our results show that, in comparison with conventional helmets, the majority of helmets incorporating new technologies significantly reduced peak rotational acceleration and velocity and maximal strain in corpus callosum and sulci. Only one helmet with MIPS significantly increased strain in the corpus collosum. The helmets fitted with MIPS and WaveCel were more effective in reducing strain in impacts producing sagittal rotations and a helmet fitted with SPIN in coronal rotations. The airbag helmet was effective in reducing brain strain in all impacts, however, peak rotational velocity and brain strain heavily depended on the analysis time. These results suggest that incorporating different impact locations in future oblique impact test methods and designing helmet technologies for the mitigation of head rotation in different planes are key to reducing brain injuries in bicycle accidents.
  •  
3.
  • Andersen, L. M., et al. (författare)
  • On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG
  • 2020
  • Ingår i: NeuroImage. - : Elsevier BV. - 1053-8119 .- 1095-9572. ; 221
  • Tidskriftsartikel (refereegranskat)abstract
    • Magnetoencephalography (MEG) has a unique capacity to resolve the spatio-temporal development of brain activity from non-invasive measurements. Conventional MEG, however, relies on sensors that sample from a distance (20–40 mm) to the head due to thermal insulation requirements (the MEG sensors function at 4 K in a helmet). A gain in signal strength and spatial resolution may be achieved if sensors are moved closer to the head. Here, we report a study comparing measurements from a seven-channel on-scalp SQUID MEG system to those from a conventional (in-helmet) SQUID MEG system. We compared the spatio-temporal resolution between on-scalp and conventional MEG by comparing the discrimination accuracy for neural activity patterns resulting from stimulating five different phalanges of the right hand. Because of proximity and sensor density differences between on-scalp and conventional MEG, we hypothesized that on-scalp MEG would allow for a more high-resolved assessment of these activity patterns, and therefore also a better classification performance in discriminating between neural activations from the different phalanges. We observed that on-scalp MEG provided better classification performance during an early post-stimulus period (10–20 ms). This corresponded to the electroencephalographic (EEG) component P16/N16 and was an unexpected observation as this component is usually not observed in conventional MEG. This finding shows that on-scalp MEG enables a richer registration of the cortical signal, indicating a sensitivity to what are potentially sources in the thalamo-cortical radiation. We had originally expected that on-scalp MEG would provide better classification accuracy based on activity in proximity to the P60m component compared to conventional MEG. This component indeed allowed for the best classification performance for both MEG systems (60–75%, chance 50%). However, we did not find that on-scalp MEG allowed for better classification than conventional MEG at this latency. We suggest that this absence of differences is due to the limited sensor coverage in the recording, in combination with our strategy for positioning the on-scalp MEG sensors. We show how the current sensor coverage may have limited our chances to register the necessary between-phalange source field dissimilarities for fair hypothesis testing, an approach we otherwise believe to be useful for future benchmarking measurements. © 2020 The Authors
  •  
4.
  • Bado, Mattia Francesco, et al. (författare)
  • Distributed optical fiber sensing bonding techniques performance for embedment inside reinforced concrete structures
  • 2020
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 20:20, s. 1-23
  • Tidskriftsartikel (refereegranskat)abstract
    • Distributed optical fiber sensors (DOFS) are modern-day cutting-edge monitoring tools that are quickly acquiring relevance in structural health monitoring engineering. Their most ambitious use is embedded inside plain or reinforced concrete (RC) structures with the scope of comprehending their inner-workings and the functioning of the concrete-reinforcement interaction. Yet, multiple studies have shown that the bonding technique with which the DOFS are bonded to the reinforcement bars has a significant role on the quality of the extracted strain data. Whilst this influence has been studied for externally bonded DOFS, it has not been done for embedded ones. The present article is set on performing such study by monitoring the strain measurement quality as sampled by DOFS bonded to multiple rebars with different techniques and adhesives. These instrumented rebars are used to produce differently sized RC ties later tested in tension. The discussion of the test outputs highlights the quasi-optimal performance of a DOFS/rebar bonding technique consisting of incising a groove in the rebar, positioning the DOFS inside it, bonding it with cyanoacrylate and later adding a protective layer of silicone. The resulting data is mostly noisefree and anomalies-free, yet still presents a newly diagnosed hitch that needs addressing in future research.
  •  
5.
  • Campanini, Isabella, et al. (författare)
  • Fundamental Concepts of Bipolar and High-Density Surface EMG Understanding and Teaching for Clinical, Occupational, and Sport Applications: Origin, Detection, and Main Errors
  • 2022
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 22:11
  • Forskningsöversikt (refereegranskat)abstract
    • Surface electromyography (sEMG) has been the subject of thousands of scientific articles, but many barriers limit its clinical applications. Previous work has indicated that the lack of time, competence, training, and teaching is the main barrier to the clinical application of sEMG. This work follows up and presents a number of analogies, metaphors, and simulations using physical and mathematical models that provide tools for teaching sEMG detection by means of electrode pairs (1D signals) and electrode grids (2D and 3D signals). The basic mechanisms of sEMG generation are summarized and the features of the sensing system (electrode location, size, interelectrode distance, crosstalk, etc.) are illustrated (mostly by animations) with examples that teachers can use. The most common, as well as some potential, applications are illustrated in the areas of signal presentation, gait analysis, the optimal injection of botulinum toxin, neurorehabilitation, ergonomics, obstetrics, occupational medicine, and sport sciences. The work is primarily focused on correct sEMG detection and on crosstalk. Issues related to the clinical transfer of innovations are also discussed, as well as the need for training new clinical and/or technical operators in the field of sEMG.
  •  
6.
  • Candefjord, Stefan, 1981, et al. (författare)
  • A wearable microwave instrument can detect and monitor traumatic abdominal injuries in a porcine model
  • 2021
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322 .- 2045-2322. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Abdominal injury is a frequent cause of death for trauma patients, and early recognition is essential to limit fatalities. There is a need for a wearable sensor system for prehospital settings that can detect and monitor bleeding in the abdomen (hemoperitoneum). This study evaluates the potential for microwave technology to fill that gap. A simple prototype of a wearable microwave sensor was constructed using eight antennas. A realistic porcine model of hemoperitoneum was developed using anesthetized pigs. Ten animals were measured at healthy state and at two sizes of bleeding. Statistical tests and a machine learning method were used to evaluate blood detection sensitivity. All subjects presented similar changes due to accumulation of blood, which dampened the microwave signal (p< 0.05). The machine learning analysis yielded an area under the receiver operating characteristic (ROC) curve (AUC) of 0.93, showing 100% sensitivity at 90% specificity. Large inter-individual variability of the healthy state signal complicated differentiation of bleedings from healthy state. A wearable microwave instrument has potential for accurate detection and monitoring of hemoperitoneum, with automated analysis making the instrument easy-to-use. Future hardware development is necessary to suppress measurement system variability and enable detection of smaller bleedings.
  •  
7.
  • Fan, Xuelong, et al. (författare)
  • Effects of sensor types and angular velocity computational methods in field measurements of occupational upper arm and trunk postures and movements
  • 2021
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 21:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Accelerometer-based inclinometers have dominated kinematic measurements in previous field studies, while the use of inertial measurement units that additionally include gyroscopes is rapidly increasing. Recent laboratory studies suggest that these two sensor types and the two commonly used angular velocity computational methods may produce substantially different results. The aim of this study was, therefore, to evaluate the effects of sensor types and angular velocity computational methods on the measures of work postures and movements in a real occupational setting. Half-workday recordings of arm and trunk postures, and movements from 38 warehouse workers were compared using two sensor types: accelerometers versus accelerometers with gyroscopes—and using two angular velocity computational methods, i.e., inclination velocity versus generalized velocity. The results showed an overall small difference (<2° and value independent) for posture percentiles between the two sensor types, but substantial differences in movement percentiles both between the sensor types and between the angular computational methods. For example, the group mean of the 50th percentiles were for accelerometers: 71°/s (generalized velocity) and 33°/s (inclination velocity)—and for accelerometers with gyroscopes: 31°/s (generalized velocity) and 16°/s (inclination velocity). The significant effects of sensor types and angular computational methods on angular velocity measures in field work are important in inter-study comparisons and in comparisons to recommended threshold limit values.
  •  
8.
  • Fernandez, Ignasi, 1984, et al. (författare)
  • Long-term performance of distributed optical fiber sensors embedded in reinforced concrete beams under sustained deflection and cyclic loading
  • 2021
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 21:19
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper explores the performance of distributed optical fiber sensors based on Rayleigh backscattering for the monitoring of strains in reinforced concrete elements subjected to different types of long-term external loading. In particular, the reliability and accuracy of robust fiber optic cables with an inner steel tube and an external protective polymeric cladding were investigated through a series of laboratory experiments involving large-scale reinforced concrete beams subjected to either sustained deflection or cyclic loading for 96 days. The unmatched spatial resolution of the strain measurements provided by the sensors allows for a level of detail that leads to new insights in the understanding of the structural behavior of reinforced concrete specimens. Moreover, the accuracy and stability of the sensors enabled the monitoring of subtle strain variations, both in the short-term due to changes of the external load and in the long-term due to time-dependent effects such as creep. Moreover, a comparison with Digital Image Correlation measurements revealed that the strain measurements and the calculation of deflection and crack widths derived thereof remain accurate over time. Therefore, the study concluded that this type of fiber optic has great potential to be used in real long-term monitoring applications in reinforced concrete structures.
  •  
9.
  • Forsman, Mikael, Professor, et al. (författare)
  • Mind the gap – development of conversion models between accelerometer- and IMU-based measurements of arm and trunk postures and movements in warehouse work
  • 2022
  • Ingår i: Applied Ergonomics. - : Elsevier BV. - 0003-6870 .- 1872-9126. ; 105
  • Tidskriftsartikel (refereegranskat)abstract
    • Sensor type (accelerometers only versus inertial measurement units, IMUs) and angular velocity computational method (inclination versus generalized velocity) have been shown to affect the measurements of arm and trunk movements. This study developed models for conversions between accelerometer and IMU measurements of arm and trunk inclination and between accelerometer and IMU measurements of inclination and generalized (arm) velocities. Full-workday recordings from accelerometers and IMUs of arm and trunk postures and movements from 38 warehouse workers were used to develop 4 angular (posture) and 24 angular velocity (movement) conversion models for the distributions of the data. A power function with one coefficient and one exponent was used, and it correlated well (r2 > 0.999) in all cases to the average curves comparing one measurement with another. These conversion models facilitate the comparison and merging of measurements of arm and trunk movements collected using the two sensor types and the two computational methods.
  •  
10.
  • Geng, Zeyang, 1991, et al. (författare)
  • Validity of solid-state Li + diffusion coefficient estimation by electrochemical approaches for lithium-ion batteries
  • 2022
  • Ingår i: Electrochimica Acta. - : Elsevier BV. - 0013-4686 .- 1873-3859. ; 404
  • Tidskriftsartikel (refereegranskat)abstract
    • The solid-state diffusion coefficient of the electrode active material is one of the key parameters in lithium-ion battery modelling. Conventionally, this diffusion coefficient is estimated through the galvanostatic intermittent titration technique (GITT). In this work, the validity of GITT and a faster alternative technique, intermittent current interruption (ICI), are investigated regarding their effectiveness through a black-box testing approach. A Doyle-Fuller-Newman model with parameters for a LiNi0.8Mn0.1Co0.1O2 electrode is used as a fairly faithful representation as a real battery system, and the GITT and ICI experiments are simulated to extract the diffusion coefficient. With the parameters used in this work, the results show that both the GITT and ICI methods can identify the solid-state diffusion coefficient very well compared to the value used as input into the simulation model. The ICI method allows more frequent measurement but the experiment time is 85% less than what takes to perform a GITT test. Different fitting approaches and fitting length affected the estimation accuracy, however not significantly. Moreover, a thinner electrode, a higher C-rate and a greater electrolyte diffusion coefficient will lead to an estimation of a higher solid-state diffusion coefficient, generally closer to the target value.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 265
Typ av publikation
tidskriftsartikel (185)
konferensbidrag (45)
forskningsöversikt (14)
doktorsavhandling (13)
bokkapitel (5)
licentiatavhandling (2)
visa fler...
rapport (1)
visa färre...
Typ av innehåll
refereegranskat (238)
övrigt vetenskapligt/konstnärligt (27)
Författare/redaktör
Theodorsson, Elvar (9)
Torres Company, Vict ... (9)
Fredriksson, Ingemar (7)
Strömberg, Tomas (7)
Karlsson, Magnus, 19 ... (6)
Ye, Zhichao, 1991 (6)
visa fler...
Augustine, Robin, 19 ... (6)
Enqvist, Olof, 1981 (5)
Ruffieux, Silvia, 19 ... (5)
Larsson, Marcus (5)
Perez, Mauricio D. (5)
Thiringer, Torbjörn, ... (4)
Tenje, Maria (4)
Seoane, Fernando, 19 ... (4)
Winkler, Dag, 1957 (4)
Malmsjö, Malin (4)
Ramser, Kerstin (4)
Pfeiffer, Christoph, ... (4)
Sheikh, Rafi (4)
Strömberg, Tomas, 19 ... (4)
Edenbrandt, Lars, 19 ... (4)
Gil Berrocal, Carlos ... (4)
Mandal, Bappaditya (4)
Öhberg, Fredrik, 196 ... (3)
Larsson, Anders (3)
Sandberg, Frida (3)
Laurell, Thomas (3)
Rempling, Rasmus, 19 ... (3)
Saager, Rolf B., 197 ... (3)
Malmberg, Per, 1974 (3)
Cinthio, Magnus (3)
Kalaboukhov, Alexei, ... (3)
Schneiderman, Justin ... (3)
Davies, M. B. (3)
Lacey, Matthew (3)
Albinsson, John (3)
Andrekson, Peter, 19 ... (3)
Wårdell, Karin (3)
Alshaykh, Mohammed S ... (3)
Wang, Cong (3)
O'Malley, Nathan P. (3)
Leaird, D. E. (3)
Qi, Minghao (3)
Weiner, A. M. (3)
Persson, Mikael, 195 ... (3)
Carlhäll, Carljohan (3)
Merdasa, Aboma (3)
Wahl, Joel (3)
Farnebo, Simon (3)
Fernandez, Ignasi, 1 ... (3)
visa färre...
Lärosäte
Chalmers tekniska högskola (94)
Linköpings universitet (59)
Lunds universitet (57)
Kungliga Tekniska Högskolan (27)
Uppsala universitet (24)
Göteborgs universitet (19)
visa fler...
Karolinska Institutet (15)
Umeå universitet (9)
RISE (6)
Luleå tekniska universitet (4)
Malmö universitet (4)
Högskolan i Borås (4)
Stockholms universitet (3)
Högskolan i Halmstad (2)
Mälardalens universitet (2)
Örebro universitet (2)
Högskolan i Gävle (1)
Jönköping University (1)
Högskolan i Skövde (1)
Blekinge Tekniska Högskola (1)
visa färre...
Språk
Engelska (264)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Teknik (265)
Medicin och hälsovetenskap (82)
Naturvetenskap (77)
Samhällsvetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy