Sökning: id:"swepub:oai:DiVA.org:kth-188117" >
Superficial vessel ...
Superficial vessel reconstruction with a multiview camera system
-
- Maria Marreiros, Filipe Miguel, 1978- (författare)
- Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten
-
- Rossitti, Sandro (författare)
- Linköpings universitet,Östergötlands Läns Landsting,Neurokirurgiska kliniken US,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten
-
- Karlsson, Per (författare)
- Östergötlands Läns Landsting,Neurokirurgiska kliniken US
-
visa fler...
-
- Wang, Chunliang (författare)
- Linköpings universitet,KTH,Medicinsk bildbehandling och visualisering,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Royal Institute of Technology, School of Technology and Health, Alfred Nobels Allé 10, Huddinge
-
- Gustafsson, Torbjorn (författare)
- XM Reality AB, Linköping, Sweden
-
- Carleberg, Per (författare)
- XM Reality AB, Linköping, Sweden
-
- Smedby, Örjan (författare)
- Linköpings universitet,KTH,Medicinsk bildbehandling och visualisering,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medie- och Informationsteknik,Tekniska fakulteten,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Region Östergötland, Röntgenkliniken i Linköping,Royal Institute of Technology, School of Technology and Health, Alfred Nobels Allé 10, Huddinge
-
visa färre...
-
(creator_code:org_t)
- SPIE - International Society for Optical Engineering, 2016
- 2016
- Engelska.
-
Ingår i: Journal of Medical Imaging. - : SPIE - International Society for Optical Engineering. - 2329-4302 .- 2329-4310. ; 3:1
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- We aim at reconstructing superficial vessels of the brain. Ultimately, they will serve to guide the deformation methods to compensate for the brain shift. A pipeline for three-dimensional (3-D) vessel reconstruction using three mono-complementary metal-oxide semiconductor cameras has been developed. Vessel centerlines are manually selected in the images. Using the properties of the Hessian matrix, the centerline points are assigned direction information. For correspondence matching, a combination of methods was used. The process starts with epipolar and spatial coherence constraints (geometrical constraints), followed by relaxation labeling and an iterative filtering where the 3-D points are compared to surfaces obtained using the thin-plate spline with decreasing relaxation parameter. Finally, the points are shifted to their local centroid position. Evaluation in virtual, phantom, and experimental images, including intraoperative data from patient experiments, shows that, with appropriate camera positions, the error estimates (root-mean square error and mean error) are similar to 1 mm.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
- NATURVETENSKAP -- Data- och informationsvetenskap -- Datorseende och robotik (hsv//swe)
- NATURAL SCIENCES -- Computer and Information Sciences -- Computer Vision and Robotics (hsv//eng)
Nyckelord
- brain shift correction
- three-dimensional vessel tracking
- multiview geometry
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas