(556) – Change in Acoustic Fingerprints at Increased Pump Speed During Echocardiographic Ramp Test

Sundbom, Per (author)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Kardiologiska kliniken US
Ahn, Henrik (author)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Thorax-kärlkliniken i Östergötland
Kornhall, B (author)
Skane University Hospital, Lund
show more...
Loebe, M (author)
Division of Transplant and Assist Devices at Methodist DeBakey Heart & Vascular Centre, Houston, Texas, USA
Granfeldt, Hans (author)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet,Thorax-kärlkliniken i Östergötland
show less...
 (creator_code:org_t)
Elsevier, 2014
2014
English.
In: The Journal of Heart and Lung Transplantation. - : Elsevier. - 1053-2498.
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • PurposeThe continuous flow mechanical circulatory support HeartMate II™ (Thoratec Corporation, Inc. Pleasanton, USA) (HMII), generates an auditory signal (acoustic fingerprint) that can be registered by routine auscultation. A temporary or permanent change in sound indicates a change in pump function. Previous mock loop studies have shown that changes in acoustic fingerprint are due to changes in speed, so the aim of this study was to see if the acoustic fingerprint changed during an echocardiographic ramp test.MethodsFour stable, event-free patients included in the SoundMate study performed an echocardiographic ramp test. The speed was increased stepwise by 400 rpm between 8 000 and 12 000 rpm, and the left ventricular end diastolic diameter, flow, power consumption and blood pressure were measured. Sounds from HMII were recorded using an iPhone™ (Apple Inc. Cupertino, CA, USA) with the stethoscope application iStethPro™ (Dr. Peter J Bentley, UK) and the frequency map analyzed using the Audacity™ program (Unicode, Ash, Chinen and Crook, USA). The acoustic fingerprint is divided into regions (R1: 1 000-6 500, R2: 8 500-14 000, R3: 15 000-21 000 Hz) and peaks (P1: 0-1 000, P2: 6 500-8 500, P4: 21 000-23 000 Hz) in order to facilitate calculations and clarify changes in frequency.ResultsThere were significant (p<005) changes in the acoustic fingerprint when increasing the pump speed between 8 000 and 12 000 rpm. In 2/4 patients there were no significant changes in P1, otherwise there were significant changes in all regions and peaks. During the ramp test the power increased in mean 7 W, flow 3,1 L/min and the blood pressure measured with Doppler increased by ~15 mmHg. The left ventricular size decreased with ~2 cm.ConclusionThe acoustic fingerprint changes with pump speed. This implies that when using sound check for detection of pump dysfunction, a new baseline should be set after every adjustment of speed.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Publication and Content Type

ref (subject category)
kon (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Sundbom, Per
Ahn, Henrik
Kornhall, B
Loebe, M
Granfeldt, Hans
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
Articles in the publication
The Journal of H ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view