SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-134596"
 

Sökning: id:"swepub:oai:DiVA.org:liu-134596" > Use of computed tom...

Use of computed tomography assessed kidney length to predict split renal GFR in living kidney donors

Gaillard, Francois (författare)
Paris Descartes University, France
Pavlov, Patrik (författare)
Linköpings universitet
Tissier, Anne-Marie (författare)
Paris Descartes University, France
visa fler...
Harache, Benoit (författare)
Paris Descartes University, France
Eladari, Dominique (författare)
Paris Descartes University, France; INSERM, France
Timsit, Marc-Olivier (författare)
Paris Descartes University, France
Fournier, Catherine (författare)
Paris Descartes University, France
Leon, Carine (författare)
Paris Descartes University, France
Hignette, Chantal (författare)
Paris Descartes University, France
Friedlander, Gerard (författare)
Paris Descartes University, France; INSERM, France
Correas, Jean-Michel (författare)
Paris Descartes University, France
Weinmann, Pierre (författare)
Paris Descartes University, France
Mejean, Arnaud (författare)
Paris Descartes University, France
Houillier, Pascal (författare)
Paris Descartes University, France; CNRS, France
Legendre, Christophe (författare)
Paris Descartes University, France
Courbebaisse, Marie (författare)
Paris Descartes University, France; INSERM, France
visa färre...
 (creator_code:org_t)
2016-05-24
2017
Engelska.
Ingår i: European Radiology. - : SPRINGER. - 0938-7994 .- 1432-1084. ; 27:2, s. 651-659
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Screening of living kidney donors may require scintigraphy to split glomerular filtration rate (GFR). To determine the usefulness of computed tomography (CT) to split GFR, we compared scintigraphy-split GFR to CT-split GFR. We evaluated CT-split GFR as a screening test to detect scintigraphy-split GFR lower than 40 mL/min/1.73 m(2)/kidney. This was a monocentric retrospective study on 346 potential living donors who had GFR measurement, renal scintigraphy, and CT. We predicted GFR for each kidney by splitting GFR using the following formula: Volume-split GFR for a given kidney = measured GFR*[volume of this kidney/(volume of this kidney + volume of the opposite kidney)]. The same formula was used for length-split GFR. We compared length- and volume-split GFR to scintigraphy-split GFR at donation and with a 4-year follow-up. A better correlation was observed between length-split GFR and scintigraphy-split GFR (r = 0.92) than between volume-split GFR and scintigraphy-split GFR (r = 0.89). A length-split GFR threshold of 45 mL/min/1.73 m(2)/kidney had a sensitivity of 100 % and a specificity of 75 % to detect scintigraphy-split GFR less than 40 mL/min/1.73 m(2)/kidney. Both techniques with their respective thresholds detected living donors with similar eGFR evolution during follow-up. Length-split GFR can be used to detect patients requiring scintigraphy. aEuro cent Excellent correlation between kidney length and scintigraphy predicted GFR aEuro cent Kidney length screening detects all donors with GFR lower than 40 mL/min/1.73 m (2) aEuro cent Kidney length screening can replace scintigraphy screening.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

living donor; kidney; renal transplantation; CT; split renal function/split GFR

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy