SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:liu-91233"
 

Search: id:"swepub:oai:DiVA.org:liu-91233" > Model-based registr...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Model-based registration for assessment of spinal deformities in idiopathic scoliosis

Forsberg, Daniel (author)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Lundström, Claes (author)
Linköpings universitet,Medie- och Informationsteknik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Andersson, Mats (author)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
show more...
Knutsson, Hans (author)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
show less...
 (creator_code:org_t)
2013-12-19
2014
English.
In: Physics in Medicine and Biology. - : Institute of Physics and Engineering in Medicine. - 0031-9155 .- 1361-6560. ; 59:2, s. 311-326
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Detailed analysis of spinal deformity is important within orthopaedic healthcare, in particular for assessment of idiopathic scoliosis. This paper addresses this challenge by proposing an image analysis method, capable of providing a full three-dimensional spine characterization. The proposed method is based on the registration of a highly detailed spine model to image data from computed tomography. The registration process provides an accurate segmentation of each individual vertebra and the ability to derive various measures describing the spinal deformity. The derived measures are estimated from landmarks attached to the spine model and transferred to the patient data according to the registration result. Evaluation of the method provides an average point-to-surface error of 0.9 mm ± 0.9 (comparing segmentations), and an average target registration error of 2.3 mm ± 1.7 (comparing landmarks). Comparing automatic and manual measurements of axial vertebral rotation provides a mean absolute difference of 2.5° ± 1.8, which is on a par with other computerized methods for assessing axial vertebral rotation. A significant advantage of our method, compared to other computerized methods for rotational measurements, is that it does not rely on vertebral symmetry for computing the rotational measures. The proposed method is fully automatic and computationally efficient, only requiring three to four minutes to process an entire image volume covering vertebrae L5 to T1. Given the use of landmarks, the method can be readily adapted to estimate other measures describing a spinal deformity by changing the set of employed landmarks. In addition, the method has the potential to be utilized for accurate segmentations of the vertebrae in routine computed tomography examinations, given the relatively low point-to-surface error.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Forsberg, Daniel
Lundström, Claes
Andersson, Mats
Knutsson, Hans
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Image Pr ...
Articles in the publication
Physics in Medic ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view