Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures

Christersson, Albert (författare)
Uppsala universitet,Ortopedi
Nysjö, Johan (författare)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion
Berglund, Lars (författare)
Uppsala universitet,Uppsala kliniska forskningscentrum (UCR)
visa fler...
Malmberg, Filip (författare)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion,Radiologi
Sintorn, Ida-Maria (författare)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion
Nyström, Ingela (författare)
Uppsala universitet,Avdelningen för visuell information och interaktion,Bildanalys och människa-datorinteraktion
Larsson, Sune (författare)
Uppsala universitet,Ortopedi
visa färre...
 (creator_code:org_t)
2016-02-27
2016
Engelska.
Ingår i: Skeletal Radiology. - : Springer Science and Business Media LLC. - 0364-2348 .- 1432-2161. ; 45:6, s. 763-769
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective The aim of the present study was to compare the reliability and agreement between a computer tomography-based method (CT) and digitalised 2D radiographs (XR) when measuring change in dorsal angulation over time in distal radius fractures. Materials and methods Radiographs from 33 distal radius fractures treated with external fixation were retrospectively analysed. All fractures had been examined using both XR and CT at six times over 6 months postoperatively. The changes in dorsal angulation between the first reference images and the following examinations in every patient were calculated from 133 follow-up measurements by two assessors and repeated at two different time points. The measurements were analysed using Bland-Altman plots, comparing intra- and inter-observer agreement within and between XR and CT. Results The mean differences in intra- and inter-observer measurements for XR, CT, and between XR and CT were close to zero, implying equal validity. The average intra- and inter-observer limits of agreement for XR, CT, and between XR and CT were +/- 4.4 degrees, +/- 1.9 degrees and +/- 6.8 degrees respectively. Conclusions For scientific purpose, the reliability of XR seems unacceptably low when measuring changes in dorsal angulation in distal radius fractures, whereas the reliability for the semi-automatic CT-based method was higher and is therefore preferable when a more precise method is requested.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Computerized Image Processing
Datoriserad bildbehandling

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy