SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:gup.ub.gu.se/119326"
 

Search: id:"swepub:oai:gup.ub.gu.se/119326" > Investigation of th...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Investigation of the effect of ambient lighting on contrast sensitivity using a novel method for conducting visual research on LCDs

Sund, Patrik (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Månsson, Lars Gunnar, 1951 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2010-03-08
2010
English.
In: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 62-70
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The DICOM part 14 greyscale standard display function provides one way of harmonising image appearance under different monitor luminance settings. This function is based on ideal observer conditions, where the eye is always adapted to the target luminance and thereby also at peak contrast sensitivity. Clinical workstations are, however, often submitted to variations in ambient light due to a sub-optimal reading room light environment. Also, clinical images are inhomogeneous and low-contrast patterns must be detected even at luminance levels that differ from the eye adaptation level. All deviations from ideal luminance conditions cause the observer to detect patterns with reduced eye sensitivity but the magnitude of this reduction is unclear. A method is presented to display well-defined sinusoidal low-contrast test patterns on an liquid crystal display. The observers were exposed to light from three different areas: (i) the test pattern covering approximately 2 degrees x 2 degrees ; (ii) the remaining of the display surface and (iii) ambient light from outside the display area covering most of the observers' field of view. By adjusting the luminance from each of these three areas, the observers' ability to detect low-contrast patterns under sub-optimal viewing conditions was studied. Ambient light from outside the display area has a moderate effect on the contrast threshold, except for the combination of high ambient light and dark objects, where the contrast threshold increased considerably.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Sund, Patrik
Båth, Magnus, 19 ...
Månsson, Lars Gu ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Radiation protec ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view