Sökning: id:"swepub:oai:gup.ub.gu.se/271532" >
Three-Dimensional V...
Three-Dimensional Volumetric Segmentation of Pituitary Tumors: Assessment of Inter-rater Agreement and Comparison with Conventional Geometric Equations
-
Lindberg, K. (författare)
-
Kouti, A. (författare)
-
Ziegelitz, Doerthe (författare)
-
visa fler...
-
Hallen, T. (författare)
-
- Skoglund, Thomas, 1969 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology
-
- Farahmand, Dan (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology
-
visa färre...
-
(creator_code:org_t)
- 2018-01-19
- 2018
- Engelska.
-
Ingår i: Journal of Neurological Surgery Part B-Skull Base. - : Georg Thieme Verlag KG. - 2193-6331 .- 2193-634X. ; 79:5, s. 475-481
- Relaterad länk:
-
https://europepmc.or...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background The assessment of pituitary tumor (PT) volume is important in the treatment and follow-up of patients with PT. Previously, PT volume estimation has been performed by conventional geometric equations (CGE) such as abc/2 (simplified ellipsoid volume equation) and 4 pi r(3)/3 (sphere), both presuming a symmetric tumor shape, which occurs uncommonly in patients with PT. In contrast, three-dimensional (3D) voxel-based software segmentation takes the irregular and asymmetric shapes that PTs often possess into account and might be a more accurate method for PT volume segmentation. The purpose of this study is twofold. (1) To compare 3D segmentation with CGE for PT volume estimation. (2) To assess inter-rater reliability in 3D segmentation of PTs. Methods Nineteen high-resolution (1mm slice thickness) T1-weighted MRI examinations of patients with PT were independently analyzed and manually segmented, using the software ITK-SNAP, by two certified neuroradiologists. Concurrently, the volumes of the PTs were estimated with abc/2 and 4 pi r(3)/3 by a clinician, and the results were compared with the corresponding segmented volumes. Results There was a significant decrease in PT volume attained from the segmentations compared with the calculations made with abc/2 (p < 0.001, mean volume 18% higher than segmentation) and 4 pi r(3)/3 (p < 0.001, mean volume 28% higher than segmentation). The intraclass correlation coefficient (ICC) for the two sets of segmented PTs was 0.99. Conclusion CGE (abc/2 and 4 pi r(3)/3) significantly overestimates PT volume compared with 3D volumetric segmentation. The inter-rater agreement on manual 3D volumetric software segmentation is excellent.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Neurovetenskaper (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Neurosciences (hsv//eng)
Nyckelord
- pituitary tumor volume
- volumetric analysis
- segmentation
- abc/2
- nervous-system tumors
- abc/2 estimation technique
- transsphenoidal
- surgery
- image segmentation
- adenomas
- reliability
- brain
- mr
- hemorrhage
- hematomas
- Neurosciences & Neurology
- Surgery
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas