Search: id:"swepub:oai:gup.ub.gu.se/319092" >
A retrospective cli...
A retrospective clinical study of fixed tooth- and implant-supported prostheses in titanium and cobalt-chromium-ceramic: 5-9-year follow-up
-
- Nilsson, Sheida (author)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology,The Sahlgrenska Academy, Department of Prosthodontics, Institute of Odontology, University of Gothenburg, Göteborg, Sweden
-
- Franke Stenport, Victoria, 1970 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2,The Sahlgrenska Academy, Department of Prosthodontics, Institute of Odontology, University of Gothenburg, Göteborg, Sweden
-
- Nilsson, Marco, 1971- (author)
- Jönköping University,Sustainability Education Research (SER)
-
show more...
-
- Gothberg, C. (author)
- The Institute for Postgraduate Dental Education in Jönköping, Jönköping, Sweden
-
show less...
-
(creator_code:org_t)
- 2022-06-29
- 2022
- English.
-
In: Clinical Oral Investigations. - : Springer Science and Business Media LLC. - 1432-6981 .- 1436-3771. ; 26:10, s. 6097-6103
- Related links:
-
https://doi.org/10.1...
-
show more...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
show less...
Abstract
Subject headings
Close
- Objectives The aim of this retrospective study was to evaluate the clinical outcome of fixed tooth- and implant-supported protheses manufactured in porcelain veneered cobalt-chromium (CoCr) or titanium with a follow-up period of 5-9 years. Materials and methods This study included 63 patients with a total of 86 fixed dental protheses (FDPs) (53 implant-supported and 33 tooth-supported). In total, 67 were short-span FDPs (3-5 units) and 19 were long-span FDPs (6-12 units). The FDPs were evaluated using a modified version of the California Dental Association (CDA). Results The binary regression analysis indicated that neither CoCr nor titanium had a statistically significant effect on the odds of success or survival of either tooth- or implant-supported FDPs. However, the success of FDPs was negatively affected by greater FDP length and general tooth wear. The survival of FDPs was negatively affected by increased FDP longevity. Conclusions This study found no statistically significant effect on the odds of success and survival outcomes for any combination of tooth-supported, implant-supported, porcelain-veneered CoCr, or porcelain-veneered titanium FDPs. As the number of FDPs was limited, the results should be interpreted with caution.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Keyword
- Dental materials
- Cobalt-chromium
- Titanium
- Fixed prosthodontics
- Fixed
- tooth-supported protheses
- Fixed implant-supported protheses
- complication rates
- single crowns
- survival
- failures
- alloys
- fdps
- Dentistry
- Oral Surgery & Medicine
- Cobalt-chromium
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database