SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:prod.swepub.kib.ki.se:228944081"
 

Search: id:"swepub:oai:prod.swepub.kib.ki.se:228944081" > Renal volumetry wit...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Renal volumetry with magnetic resonance imaging

Christensen, RH (author)
Lundgren, T (author)
Karolinska Institutet
Stenvinkel, P (author)
Karolinska Institutet
show more...
Brismar, TB (author)
Karolinska Institutet
show less...
 (creator_code:org_t)
2017-09-14
2017
English.
In: Acta radiologica open. - : SAGE Publications. - 2058-4601. ; 6:9, s. 2058460117731120-
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • No gold standard exists for renal volumetry in vivo. Purpose To devise and evaluate segmentation methods on magnetic resonance imaging (MRI) datasets. Material and Methods Five combinations of MRI pulse sequences and measuring methods were used to measure the renal volumes of five men aged 54–72 years scanned before autologous renal stem cell transplantation and three, six, and 12 months post transplantation. Results Renal volume did not change after stem cell transplantation. The results varied considerably: the reproducibility (coefficient of variation) was 4.0–6.0% and measurements took 1–13 min per kidney. Manual segmentation of images from the volumetric interpolated breath-hold examination (VIBE) without fat saturation sequence provided best reproducibility but was time-consuming. Use of the ellipsoid formula from half Fourier acquisition single shot turbo spin echo (HASTE) provided the fastest measurement, but resulted in lower reproducibility. Conclusion Renal volumetry based on images from the pulse sequence VIBE without fat saturation acquired using an out-of-phase TE may be investigated further, possibly in combination with the quick ellipsoid formula.

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Christensen, RH
Lundgren, T
Stenvinkel, P
Brismar, TB
Articles in the publication
Acta radiologica ...
By the university
Karolinska Institutet

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view