SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:research.chalmers.se:3d493952-f01c-4460-8557-287643af0086"
 

Search: id:"swepub:oai:research.chalmers.se:3d493952-f01c-4460-8557-287643af0086" > Hit detection in se...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Hit detection in serial femtosecond crystallography using X-ray spectroscopy of plasma emission

Jonsson, H. O. (author)
Uppsala universitet,Uppsala University
Caleman, C. (author)
Uppsala universitet,Uppsala University,Deutsches Elektronen-Synchrotron (DESY)
Andreasson, Jakob, 1975 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show more...
Timneanu, N. (author)
Uppsala universitet,Uppsala University
show less...
 (creator_code:org_t)
2017-10-13
2017
English.
In: IUCrJ. - : International Union of Crystallography (IUCr). - 2052-2525. ; 4, s. 778-784
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Serial femtosecond crystallography is an emerging and promising method for determining protein structures, making use of the ultrafast and bright X-ray pulses from X-ray free-electron lasers. The upcoming X-ray laser sources will produce well above 1000 pulses per second and will pose a new challenge: how to quickly determine successful crystal hits and avoid a high-rate data deluge. Proposed here is a hit-finding scheme based on detecting photons from plasma emission after the sample has been intercepted by the X-ray laser. Plasma emission spectra are simulated for systems exposed to high-intensity femtosecond pulses, for both protein crystals and the liquid carrier systems that are used for sample delivery. The thermal radiation from the glowing plasma gives a strong background in the XUV region that depends on the intensity of the pulse, around the emission lines from light elements (carbon, nitrogen, oxygen). Sample hits can be reliably distinguished from the carrier liquid based on the characteristic emission lines from heavier elements present only in the sample, such as sulfur. For buffer systems with sulfur present, selenomethionine substitution is suggested, where the selenium emission lines could be used both as an indication of a hit and as an aid in phasing and structural reconstruction of the protein.

Subject headings

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Keyword

serial femtosecond crystallography
hit detection
protein structure
plasma emission spectra

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

  • IUCrJ (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Jonsson, H. O.
Caleman, C.
Andreasson, Jako ...
Timneanu, N.
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Physical Science ...
and Atom and Molecul ...
Articles in the publication
IUCrJ
By the university
Chalmers University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view