Standardised measurements used to order compression garments can be used to calculate arm volumes to evaluate lymphoedema treatment.

Brorson, Håkan (author)
Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups
Höijer, Patrik (author)
 (creator_code:org_t)
2012
2012
English.
In: Journal of Plastic Surgery and Hand Surgery. - 2000-656X. ; 46:6, s. 410-415
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Abstract Lymphoedema treatment outcome can be evaluated by calculating estimated limb volumes directly by water displacement (plethysmography; PG), or indirectly by circumference measurements (CM) and using the formula for a truncated cone. This study assessed the correlation between PG and circumference volume measurements to assess whether the correlation is acceptable, and if circumference measurements can be used to accurately assess arm volume. Ten women with unilateral lymphoedema after breast cancer treatment with a mean age of 66 (range 50-83) years volunteered for arm volume estimates by PG and circumference measurements. The coefficient of variation (CV%) for all methods was calculated. Two Excel-based formulae of the truncated cone were developed; one for fixed 4-cm intervals leading to 10 volume segments (CM-10-VS), and one for varying intervals leading to four volume segments (CM-4-VS). The CV% was 0.609% for PG, 0.628% for CM-10-VS, and 0.632% for CM-4-VS. As expected, PG generated a significantly larger volume of both arms because it includes the hand. The difference between CM-10-VS and CM-4-VS measurements was not significant. All three measurement methods showed a high coefficient of correlation (0.813-0.915), and a high coefficient of regression (0.863-1.089). The excess volume, which is used to determine treatment outcome, showed the respective values of 0.932-0.978 and 0.963-1.020, respectively. Using circumference measurements identical to those used when ordering made-to-measure compression garments speeds up volume measurements and can be used safely to evaluate lymphoedema treatment outcome.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Brorson, Håkan
Höijer, Patrik
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
Articles in the publication
Journal of Plast ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view