Heat Production, Nerve Function, and Morphology following Nerve Close Dissection with Surgical Instruments

Carlander, Johan (author)
Linköpings universitet,Institutionen för klinisk och experimentell medicin,Hälsouniversitetet
Koch, C (author)
Phys Technical Bundesanstalt
Brudin, L (author)
Kalmar Hospital
show more...
Nordborg, C (author)
Sahlgrens University Hospital
Gimm, Oliver (author)
Östergötlands Läns Landsting,Linköpings universitet,Institutionen för klinisk och experimentell medicin,Hälsouniversitetet,Kirurgiska kliniken i Östergötland
Johansson, K (author)
Linköpings universitet,Institutionen för klinisk och experimentell medicin,Hälsouniversitetet
show less...
 (creator_code:org_t)
2012-02-25
2012
English.
In: World Journal of Surgery. - : Springer Verlag (Germany). - 0364-2313 .- 1432-2323. ; 36:6, s. 1361-1367
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The aim of the present study was to compare an ultrasonically activated instrument (US), monopolar electrosurgery, and bipolar electrosurgery (ES) with respect to heat production, nerve function, and nerve morphology following in vivo application. less thanbrgreater than less thanbrgreater thanThe biceps femoris muscle of anesthetized rats was cut in a standardized manner longitudinally 1 mm adjacent to the sciatic nerve using US shears, a monopolar ES knife, or a bipolar ES scissors. Activation time and temperature were recorded continuously within 1-4 mm of the activation site ipsilateral and contralateral to the nerve with two thermoelectric microsensors. Temperature rise and time delay of reaching the temperature maximum, as an expression of heat spread within tissue, maximum temperature, and thermal dose (equivalent time of exposure at 43A degrees C) were measured and calculated. A total of 49 functional experiments were conducted. The electromyographic (EMG) potential was recorded distally. Nerve dysfunction was defined as more than 10% loss of the evoked EMG amplitude. Forty-eight nerves were coded and submitted to blind histopathological examination, and morphological damage was graded on a 4-grade scale. less thanbrgreater than less thanbrgreater thanThe maximum temperature elevation and the thermal dose were significantly higher for the bipolar ES compared with the US instrument ( = 0.024, = 0.049), and with much less variation of results for the US instrument. The monopolar ES maximum temperature and thermal dose were lower, but a very large variation occurred, probably as a result of more random electrical spread to the ground electrode and muscle motion artifacts. Functional loss was least common in the US group-without being significant-compared to bipolar and monopolar ES. Moderate and severe morphological damage was significantly less common in the US group than in the monopolar ES group ( = 0.041). We found no statistically significant correlation between the highest temperatures and the degree of morphological damage or functional loss less thanbrgreater than less thanbrgreater thanThe temperature elevation depends strongly on the distance to the activated instrument. The bipolar ES scissors generates a higher maximum temperature and thermal dose with a greater variation in than the US. Functional loss and severe morphological damage were uncommon in all groups.

Keyword

MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view