SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Williams Garth) srt2:(2015-2019)"

Sökning: WFRF:(Williams Garth) > (2015-2019)

  • Resultat 11-18 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
11.
  • Munke, Anna, et al. (författare)
  • Data Descriptor : Coherent diffraction of single Rice Dwarf virus particles using hard X-rays at the Linac Coherent Light Source
  • 2016
  • Ingår i: Scientific Data. - : Nature Publishing Group. - 2052-4463. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a wellcharacterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 mu m diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 angstrom ngstrom were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.
  •  
12.
  • Nass, Karol, et al. (författare)
  • Indications of radiation damage in ferredoxin microcrystals using high-intensity X-FEL beams
  • 2015
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 22:2, s. 225-238
  • Tidskriftsartikel (refereegranskat)abstract
    • Proteins that contain metal cofactors are expected to be highly radiation sensitive since the degree of X-ray absorption correlates with the presence of high-atomic-number elements and X-ray energy. To explore the effects of local damage in serial femtosecond crystallography (SFX), Clostridium ferredoxin was used as a model system. The protein contains two [4Fe–4S] clusters that serve as sensitive probes for radiation-induced electronic and structural changes. High-dose room-temperature SFX datasets were collected at the Linac Coherent Light Source of ferredoxin microcrystals. Difference electron density maps calculated from high-dose SFX and synchrotron data show peaks at the iron positions of the clusters, indicative of decrease of atomic scattering factors due to ionization. The electron density of the two [4Fe–4S] clusters differs in the FEL data, but not in the synchrotron data. Since the clusters differ in their detailed architecture, this observation is suggestive of an influence of the molecular bonding and geometry on the atomic displacement dynamics following initial photoionization. The experiments are complemented by plasma code calculations.
  •  
13.
  • Nicolas, Aude, et al. (författare)
  • Genome-wide Analyses Identify KIF5A as a Novel ALS Gene
  • 2018
  • Ingår i: Neuron. - : Cell Press. - 0896-6273 .- 1097-4199. ; 97:6, s. 1268-1283.e6
  • Tidskriftsartikel (refereegranskat)abstract
    • To identify novel genes associated with ALS, we undertook two lines of investigation. We carried out a genome-wide association study comparing 20,806 ALS cases and 59,804 controls. Independently, we performed a rare variant burden analysis comparing 1,138 index familial ALS cases and 19,494 controls. Through both approaches, we identified kinesin family member 5A (KIF5A) as a novel gene associated with ALS. Interestingly, mutations predominantly in the N-terminal motor domain of KIF5A are causative for two neurodegenerative diseases: hereditary spastic paraplegia (SPG10) and Charcot-Marie-Tooth type 2 (CMT2). In contrast, ALS-associated mutations are primarily located at the C-terminal cargo-binding tail domain and patients harboring loss-of-function mutations displayed an extended survival relative to typical ALS cases. Taken together, these results broaden the phenotype spectrum resulting from mutations in KIF5A and strengthen the role of cytoskeletal defects in the pathogenesis of ALS.
  •  
14.
  • Popp, David, et al. (författare)
  • Flow-aligned, single-shot fiber diffraction using a femtosecond X-ray free-electron laser
  • 2017
  • Ingår i: CYTOSKELETON. - : WILEY. - 1949-3584 .- 1949-3592. ; 74:12, s. 472-481
  • Tidskriftsartikel (refereegranskat)abstract
    • A major goal for X-ray free-electron laser (XFEL) based science is to elucidate structures of biological molecules without the need for crystals. Filament systems may provide some of the first single macromolecular structures elucidated by XFEL radiation, since they contain one-dimensional translational symmetry and thereby occupy the diffraction intensity region between the extremes of crystals and single molecules. Here, we demonstrate flow alignment of as few as 100 filaments (Escherichia coli pili, F-actin, and amyloid fibrils), which when intersected by femtosecond X-ray pulses result in diffraction patterns similar to those obtained from classical fiber diffraction studies. We also determine that F-actin can be flow-aligned to a disorientation of approximately 5 degrees. Using this XFEL-based technique, we determine that gelsolin amyloids are comprised of stacked -strands running perpendicular to the filament axis, and that a range of order from fibrillar to crystalline is discernable for individual -synuclein amyloids.
  •  
15.
  • Reddy, Hemanth K. N., et al. (författare)
  • Coherent soft X-ray diffraction imaging of coliphage PR772 at the Linac coherent light source
  • 2017
  • Ingår i: Scientia Danica. Series H. Humanistica 4. - : Nature Publishing Group. - 1904-5506 .- 2052-4463. ; 4
  • Tidskriftsartikel (refereegranskat)abstract
    • Single-particle diffraction from X-ray Free Electron Lasers offers the potential for molecular structure determination without the need for crystallization. In an effort to further develop the technique, we present a dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source. The diameter of PR772 ranges from 65-70 nm, which is considerably smaller than the previously reported similar to 600 nm diameter Mimivirus. This reflects continued progress in XFEL-based single-particle imaging towards the single molecular imaging regime. The data set contains significantly more single particle hits than collected in previous experiments, enabling the development of improved statistical analysis, reconstruction algorithms, and quantitative metrics to determine resolution and self-consistency.
  •  
16.
  • Rose, Max, et al. (författare)
  • Single-particle imaging without symmetry constraints at an X-ray free-electron laser
  • 2018
  • Ingår i: IUCrJ. - : INT UNION CRYSTALLOGRAPHY. - 2052-2525. ; 5, s. 727-736
  • Tidskriftsartikel (refereegranskat)abstract
    • The analysis of a single-particle imaging (SPI) experiment performed at the AMO beamline at LCLS as part of the SPI initiative is presented here. A workflow for the three-dimensional virus reconstruction of the PR772 bacteriophage from measured single-particle data is developed. It consists of several well defined steps including single-hit diffraction data classification, refined filtering of the classified data, reconstruction of three-dimensional scattered intensity from the experimental diffraction patterns by orientation determination and a final three-dimensional reconstruction of the virus electron density without symmetry constraints. The analysis developed here revealed and quantified nanoscale features of the PR772 virus measured in this experiment, with the obtained resolution better than 10 nm, with a clear indication that the structure was compressed in one direction and, as such, deviates from ideal icosahedral symmetry.
  •  
17.
  • Sellberg, Jonas A., et al. (författare)
  • How Cubic Can Ice Be?
  • 2017
  • Ingår i: The Journal of Physical Chemistry Letters. - : American Chemical Society (ACS). - 1948-7185. ; 8:14, s. 3216-3222
  • Tidskriftsartikel (refereegranskat)abstract
    • Using an X-ray laser, we investigated the crystal structure of ice formed by homogeneous ice nucleation in deeply supercooled water nanodrops (r approximate to 10 nm) at similar to 225 K The nanodrops were formed by condensation of vapor in a supersonic nozzle, and the ice was probed within 100 mu s of freezing using femtosecond wide-angle X-ray scattering at the Linac Coherent Light Source free-electron X-ray laser. The X-ray diffraction spectra indicate that this ice has a metastable, predominantly cubic structure; the shape of the first ice diffraction peak suggests stacking-disordered ice with a cubicity value, chi, in the range of 0.78 +/- 0.05. The cubicity value determined here is higher than those determined in experiments with micron-sized drops but comparable to those found in molecular dynamics simulations. The high cubicity is most likely caused by the extremely low freezing temperatures and by the rapid freezing, which occurs on a similar to 1 mu s time scale in single nanodroplets.
  •  
18.
  • Szlachetko, Jakub, et al. (författare)
  • Establishing nonlinearity thresholds with ultraintense X-ray pulses
  • 2016
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray techniques have evolved over decades to become highly refined tools for a broad range of investigations. Importantly, these approaches rely on X-ray measurements that depend linearly on the number of incident X-ray photons. The advent of X-ray free electron lasers (XFELs) is opening the ability to reach extremely high photon numbers within ultrashort X-ray pulse durations and is leading to a paradigm shift in our ability to explore nonlinear X-ray signals. However, the enormous increase in X-ray peak power is a double-edged sword with new and exciting methods being developed but at the same time well-established techniques proving unreliable. Consequently, accurate knowledge about the threshold for nonlinear X-ray signals is essential. Herein we report an X-ray spectroscopic study that reveals important details on the thresholds for nonlinear X-ray interactions. By varying both the incident X-ray intensity and photon energy, we establish the regimes at which the simplest nonlinear process, two-photon X-ray absorption (TPA), can be observed. From these measurements we can extract the probability of this process as a function of photon energy and confirm both the nature and sub-femtosecond lifetime of the virtual intermediate electronic state.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 11-18 av 18
Typ av publikation
tidskriftsartikel (18)
Typ av innehåll
refereegranskat (18)
Författare/redaktör
Barty, Anton (12)
Williams, Garth J. (11)
Boutet, Sébastien (9)
Sellberg, Jonas A. (9)
Messerschmidt, Marc (8)
Maia, Filipe R. N. C ... (7)
visa fler...
Loh, N. Duane (7)
Aquila, Andrew (6)
Timneanu, Nicusor (6)
Svenda, Martin (6)
Bielecki, Johan (6)
Chapman, Henry N. (6)
Seibert, Marvin (6)
Nettelblad, Carl (6)
van der Schot, Gijs (6)
Hajdu, Janos (5)
Daurer, Benedikt J. (5)
Hantke, Max F. (5)
Larsson, Daniel S. D ... (5)
Westphal, Daniel (5)
Mühlig, Kerstin (5)
Williams, Garth (5)
Sierra, Raymond G. (4)
Mancuso, Adrian P. (4)
Ekeberg, Tomas (4)
Yoon, Chun Hong (4)
Vartanyants, Ivan A. (4)
Bean, Richard (4)
Beyerlein, Kenneth R ... (4)
Reddy, Hemanth K. N. (4)
Okamoto, Kenta (4)
Seibert, M Marvin (3)
Neutze, Richard, 196 ... (3)
Brändén, Gisela, 197 ... (3)
Kirian, Richard A. (3)
Fromme, Petra (3)
Arnlund, David (3)
DePonte, Daniel P. (3)
Rose, Max (3)
DeMirci, Hasan (3)
Kurta, Ruslan P. (3)
Hogue, Brenda G. (3)
Awel, Salah (3)
Ayyer, Kartik (3)
Koglin, Jason E. (3)
Hasse, Dirk (3)
Munke, Anna (3)
Pietrini, Alberto (3)
Harimoorthy, Rajiv (3)
Zani, Alessandro (3)
visa färre...
Lärosäte
Uppsala universitet (13)
Kungliga Tekniska Högskolan (8)
Göteborgs universitet (3)
Umeå universitet (2)
Stockholms universitet (2)
Chalmers tekniska högskola (2)
Språk
Engelska (18)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (16)
Teknik (2)
Medicin och hälsovetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy