SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(FALK S) srt2:(2020-2024)"

Sökning: WFRF:(FALK S) > (2020-2024)

  • Resultat 21-30 av 63
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
21.
  • Streeter, M. J.V., et al. (författare)
  • Characterization of laser wakefield acceleration efficiency with octave spanning near-IR spectrum measurements
  • 2022
  • Ingår i: Physical Review Accelerators and Beams. - 2469-9888. ; 25:10
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield and from the plasma to the accelerated electron beam was diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximized at 19±3% by tuning the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimization of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.
  •  
22.
  •  
23.
  • Aboulatta, L, et al. (författare)
  • Preterm birth and stillbirth rates associated with socioeconomic disparities during COVID-19 pandemic: a population-based cross-sectional study
  • 2023
  • Ingår i: BMJ paediatrics open. - : BMJ. - 2399-9772. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Conflicting evidence exists on the impact of the COVID-19 pandemic restrictions on preterm birth (PTB) and stillbirth rates. We aimed to evaluate changes in PTB and stillbirth rates before and during the pandemic period and assess the potential effect modification of socioeconomic status (SES).MethodsUsing the linked administrative health databases from Manitoba, Canada, we conducted a cross-sectional study among all pregnant women, comparing 3.5 years pre-pandemic (1 October 2016 to 29 February 2020) to the first year of the pandemic (1 March 2020 to 31 March 2021). We used generalised linear models to assess the quarterly rates of PTB (<37 weeks) and stillbirths. We calculated the predicted trends based on pre-pandemic period data. Finally, we evaluated the PTB and stillbirth rates among lower and higher SES pregnant women (average annual household income) using subgroup analysis and interaction models.ResultsWe examined 70 931 pregnancies in Manitoba during the study period. The risk of PTB increased by 7.7% (95%CI 1.01 to 1.13) and stillbirths by 33% (95% CI 1.08 to 1.64) during the pandemic period. Following COVID-19 restrictions implemented in March 2020, there were increases in the quarterly rates of both PTB (immediate increase (β2)=1.37; p=0.0247) and stillbirths (immediate increase (β2)=0.12; p=0.4434). Among the lower income groups, the pandemic restrictions resulted in an immediate relative increase in PTB and stillbirth rates by 20.12% (immediate increase (β2)=3.17; p=0.0057) and 27.19% (immediate increase (β2)=0.48; p=0.0852). However, over the pandemic, the overall PTB rate significantly decreased as a rebound effect by 0.85% per quarter (p=0.0004), whereas the overall stillbirth rate did not decrease significantly (slope decrease (β3) =−0.01; p=0.8296) compared with the pre-pandemic period. The quarterly rates during the pandemic among the higher income group decreased by 0.39% (p=0.1296) for PTB and increased by 0.07% (p=0.1565) for stillbirth. We observed an effect modification by SES for PTB rates (p=0.047).ConclusionWhile the onset of COVID-19 pandemic restrictions was not associated with significant effects on stillbirth rates, we observed an immediate and rebound effect on PTB rates. The impact of COVID-19 on preterm birth was dependent on SES, with higher influence on families with lower SES. Further studies are needed to detect future trend changes during pandemic waves after 2021 and assess potential underlying mechanisms.
  •  
24.
  • Baldursdottir, S, et al. (författare)
  • Basic principles of neonatal bubble CPAP: effects on CPAP delivery and imposed work of breathing when altering the original design
  • 2020
  • Ingår i: Archives of disease in childhood. Fetal and neonatal edition. - : BMJ. - 1468-2052 .- 1359-2998. ; 105:5, s. 550-554
  • Tidskriftsartikel (refereegranskat)abstract
    • The original bubble continuous positive airway pressure (bCPAP) design has wide-bore tubing and a low-resistance interface. This creates a stable airway pressure that is reflected by the submersion depth of the expiratory tubing. Several systems with alterations to the original bCPAP design are now available. Most of these are aimed for use in low-income and middle-income countries and have not been compared with the original design.ObjectiveWe identified three major alterations to the original bCPAP design: (1) resistance of nasal interface, (2) volume of dead space and (3) diameter of expiratory tubing. Our aim was to study the effect of these alterations on CPAP delivery and work of breathing in a mechanical lung model. Dead space should always be avoided and was not further tested.MethodsThe effect of nasal interface resistance and expiratory tubing diameter was evaluated with simulated breathing in a mechanical lung model without interface leakage. The main outcome was delivered CPAP and imposed work of breathing.ResultsHigh-resistance interfaces and narrow expiratory tubing increased the work of breathing. Additionally, narrow expiratory tubing resulted in higher CPAP levels than indicated by the submersion depth.ConclusionOur study shows the significant effect on CPAP delivery and imposed work of breathing when using high-resistance interfaces and narrow expiratory tubing in bCPAP systems. New systems should include low-resistance interfaces and wide-bore tubing and be compared with the original bCPAP. Referring to all systems that bubble as bCPAP is misleading and potentially hazardous.
  •  
25.
  • Becker, M, et al. (författare)
  • Presynaptic dysfunction in CASK-related neurodevelopmental disorders
  • 2020
  • Ingår i: Translational psychiatry. - : Springer Science and Business Media LLC. - 2158-3188. ; 10:1, s. 312-
  • Tidskriftsartikel (refereegranskat)abstract
    • CASK-related disorders are genetically defined neurodevelopmental syndromes. There is limited information about the effects of CASK mutations in human neurons. Therefore, we sought to delineate CASK-mutation consequences and neuronal effects using induced pluripotent stem cell-derived neurons from two mutation carriers. One male case with autism spectrum disorder carried a novel splice-site mutation and a female case with intellectual disability carried an intragenic tandem duplication. We show reduction of CASK protein in maturing neurons from the mutation carriers, which leads to significant downregulation of genes involved in presynaptic development and of CASK protein interactors. Furthermore, CASK-deficient neurons showed decreased inhibitory presynapse size as indicated by VGAT staining, which may alter the excitatory–inhibitory (E/I) balance in developing neural circuitries. Using in vivo magnetic resonance spectroscopy quantification of GABA in the male mutation carrier, we further highlight the possibility to validate in vitro cellular data in the brain. Our data show that future pharmacological and clinical studies on targeting presynapses and E/I imbalance could lead to specific treatments for CASK-related disorders.
  •  
26.
  •  
27.
  • Falk, M, et al. (författare)
  • Interface leakage during neonatal CPAP treatment: a randomised, cross-over trial
  • 2021
  • Ingår i: Archives of disease in childhood. Fetal and neonatal edition. - : BMJ. - 1468-2052 .- 1359-2998. ; 106:6, s. F663-F667
  • Tidskriftsartikel (refereegranskat)abstract
    • To determine leakage for two neonatal continuous positive airway pressure (CPAP) interfaces and evaluate leak-corrective manoeuvres.DesignThe ToNIL (Trial of NCPAP Interface Leakage) study was a randomised, clinical, cross-over trial with data collection between August 2018 and October 2019. The primary outcome was blinded to the treating staff.SettingOne secondary, 8-bed neonatal intensive care unit (NICU) and three larger (>15 beds), academic NICU referral centres.PatientsNewborn infants with CPAP were screened (n=73), and those with stable spontaneous breathing, low oxygen requirement, postmenstrual age (PMA) over 28 weeks and no comorbidities were eligible. In total, 50 infants were included (median PMA 33 completed weeks).InterventionsLeakage was measured for both prongs and nasal mask, before and after leak-corrective manoeuvres. Interface application was performed in a randomised order by a nurse, blinded to the measured leakage.Main outcome measures30 s average leakage, measured in litres per minute (LPM).ResultsAnalyses showed a significantly lower leakage (mean difference 0.86 LPM, 95% CI 0.07 to 1.65) with prongs (median 2.01 LPM, IQR 1.00–2.80) than nasal mask (median 2.45 LPM, IQR 0.99–5.11). Leak-corrective manoeuvres reduced leakage significantly for both prongs (median 1.22 LPM, IQR 0.54–1.87) and nasal mask (median 2.35 LPM, IQR 0.76–4.75).ConclusionsLarge leakages were common for both interfaces, less with prongs. Simple care manoeuvres reduced leakage for both interfaces. This is the first report of absolute leakage for nasal interfaces and should encourage further studies on leakage during CPAP treatment.
  •  
28.
  •  
29.
  • Gunnarsdottir, K, et al. (författare)
  • Do newborn infants exhale through the CPAP system? Secondary analysis of a randomised cross-over trial
  • 2023
  • Ingår i: Archives of disease in childhood. Fetal and neonatal edition. - : BMJ. - 1468-2052 .- 1359-2998. ; 108:3, s. 232-236
  • Tidskriftsartikel (refereegranskat)abstract
    • During nasal continuous positive airway pressure (nCPAP) treatment in neonates, leakage is inevitable and can lead to reduced distending pressure in the lungs of the infant. In current practice, neither leakage nor expiratory flow is measured, which makes it difficult to assess if exhalation is through the device or entirely through leakages.ObjectiveTo examine if infants treated with nCPAP exhale through the CPAP system.Design and settingSecondary data analyses from the ToNIL trial on leakages during nCPAP treatment. We retrospectively examined respiratory curves for the 50 infants included in the trial, using NI LabVIEW 2015. Each infant was measured with both prongs and nasal masks. A flow recording was classified as exhalation through the system if more than 50% of all expirations showed reverse flow, each for a minimum duration of 0.1 s.Patients50 infants were included, born with a mean gestational age (GA) of 34 weeks, median birth weight of 1948 g and mean age at measurement 6.5 days. Inclusion criteria were CPAP treatment and a postmenstrual age (PMA) of 28–42 weeks.ResultsIn our measurements, 32/50 infants exhaled through the CPAP system in at least one recording with either nasal mask or prongs. Leakages exceeding 0.3 L/min were seen in 97/100 recordings.ConclusionsDuring nCPAP treatment, infants can exhale through the CPAP system and leakage was common. Measuring expiratory flows and leakages in clinical settings could be valuable in optimising CPAP treatment of infants.Trial registration numberNCT03586856.
  •  
30.
  • Hober, Sophia, Professor, 1965-, et al. (författare)
  • Systematic evaluation of SARS-CoV-2 antigens enables a highly specific and sensitive multiplex serological COVID-19 assay
  • 2021
  • Ingår i: Clinical & Translational Immunology. - : Wiley. - 2050-0068. ; 10:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. The COVID-19 pandemic poses an immense need for accurate, sensitive and high-throughput clinical tests, and serological assays are needed for both overarching epidemiological studies and evaluating vaccines. Here, we present the development and validation of a high-throughput multiplex bead-based serological assay. Methods. More than 100 representations of SARS-CoV-2 proteins were included for initial evaluation, including antigens produced in bacterial and mammalian hosts as well as synthetic peptides. The five best-performing antigens, three representing the spike glycoprotein and two representing the nucleocapsid protein, were further evaluated for detection of IgG antibodies in samples from 331 COVID-19 patients and convalescents, and in 2090 negative controls sampled before 2020. Results. Three antigens were finally selected, represented by a soluble trimeric form and the S1-domain of the spike glycoprotein as well as by the C-terminal domain of the nucleocapsid. The sensitivity for these three antigens individually was found to be 99.7%, 99.1% and 99.7%, and the specificity was found to be 98.1%, 98.7% and 95.7%. The best assay performance was although achieved when utilising two antigens in combination, enabling a sensitivity of up to 99.7% combined with a specificity of 100%. Requiring any two of the three antigens resulted in a sensitivity of 99.7% and a specificity of 99.4%. Conclusion. These observations demonstrate that a serological test based on a combination of several SARS-CoV-2 antigens enables a highly specific and sensitive multiplex serological COVID-19 assay.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 63

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy