SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1097 0231 OR L773:0951 4198 srt2:(2000-2004)"

Sökning: L773:1097 0231 OR L773:0951 4198 > (2000-2004)

  • Resultat 1-25 av 52
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Palmblad, Magnus, et al. (författare)
  • Analysis of Enzymatically Digested Proteins and Protein Mixtures using a 9.4 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
  • 2000
  • Ingår i: Rapid Communications in Mass Spectrometry. - 0951-4198 .- 1097-0231. ; 14:12, s. 1029-1034
  • Tidskriftsartikel (refereegranskat)abstract
    • A commercially available 9.4 Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer was applied in the analysis of tryptic digests of protein mixtures without any separation. First, the method was demonstrated on a mixture of tryptic digests of equine cytochrome c, equine myoglobin and bovine serum albumin. The same method was then applied to human plasma from a healthy blood donor. Computer programs were employed to simplify analysis of the complex spectra. The 2745 peaks in the human plasma electrospray ionization FTICR spectrum could be reduced to 1165 isotopic clusters and 669 unique masses. Out of these, 82 masses matched tryptic fragments of serum albumin with mass measurement errors less than 10 ppm, covering 93% of the sequence. Another 16 masses were assigned to tryptic fragments of transferrin, covering 41% of the sequence on the 10 ppm mass measurement error level (14 within 2 ppm). The mass measurement errors were approximately normal distributed with a standard deviation of 1.7 ppm. This demonstrates the feasibility of combining the ultra-high mass resolving power and accuracy of FTICR mass spectrometry with automated computer analysis for investigating complex biological matrices.
  •  
2.
  •  
3.
  • Alsberg, T., et al. (författare)
  • Determination of hydroxyalkyl derivatives of cobalamin (vitamin B12) using reversed phase high performance liquid chromatography with electrospray tandem mass spectrometry and ultraviolet diode array detection
  • 2001
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 15:24, s. 2438-45
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrospray ionization tandem mass spectrometry (ESI-MS/MS) and ultraviolet diode array detection (UV-DAD), coupled on-line to reversed phase high performance liquid chromatography (HPLC), was used for the characterization of hydroxyalkyl derivatives of cob(I)alamin. The reduced form of vitamin B12, cob(I)alamin, denoted a supernucleophile due to its high nucleophilic strength, has shown promise as an analytical tool in studies of electrophilically reactive compounds in vitro and in vivo. A method for analysis of DNA-phosphate adducts was developed earlier utilizing the supernucleophilicity of cob(I)alamin to transfer alkyl groups from the phosphotriester configuration in DNA, with the formation of a Co-substituted alkyl-cobalamin (alkyl-Cbl) complex. For the purpose of identification and quantification of alkyl-Cbls at high sensitivity, an MS/MS method has been developed with application to a number of 2-hydroxyalkyl-cobalamins (OHalkyl-Cbls). The precursor oxiranes were reacted with cob(I)alamin, followed by clean-up and mass spectrometric analysis of the resulting OHalkyl-Cbls. It was found that ionization was highly dependent on solvent composition. By using acetonitrile/water/trifluoroacetic acid (TFA) (eluent I), the base peak was the doubly protonated molecule [M + 2H](2+), whereas acetonitrile/water/1-methylpiperidine (eluent II) yielded the singly protonated molecule [M + H](+) as the base peak. Excellent separation was obtained with eluent II, with good separation between stereoisomers, thus enabling the characterization of these by means of UV spectra. Limits of quantitation for 2-hydroxypropyl-cobalamin (OHPr-Cbl) were 0.2 and 2 pg/microL (or 0.1 and 1 fmol/microL) using selected ion recording (SIR) with eluent I and II, respectively. The obtained detection level should be sufficient for analysis of alkyl-Cbls from a wide range of toxicological applications.
  •  
4.
  • Andersson, M., et al. (författare)
  • Size and structure characterization of ethylhydroxyethyl cellulose by the combination of field-flow fractionation with other techniques. Investigation of ultralarge components
  • 2004
  • Ingår i: Biomacromolecules. - : Wiley. - 1525-7797 .- 1526-4602. ; 5:1, s. 97-105
  • Tidskriftsartikel (refereegranskat)abstract
    • Ethylhydroxyethyl cellulose (EHEC) of three different viscosity classes (EHEC I, II, and III) was analyzed by programmed cross-flow asymmetrical flow field-flow fractionation coupled to multiangle light scattering and refractive index detectors to determine their size and molar mass distribution. Two size populations were detected in the two lower viscosity classes, EHEC I and II, one high molar mass and one ultrahigh molar mass (UHM). The two covered molar masses from 10(4) up to 10(9) g.mol(-1). The highest viscosity class EHEC III was less size-dispersed covering molar masses from 5x10(5) to 5x10(7) g.mol(-1). Filtering of the EHEC II solution removed small amounts of compact UHM material. Enzyme treatments were performed on EHEC II to further characterize it. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and anion ion-exchange chromatography coupled to pulsed amperometric detection showed that the UHM component contained EHEC.
  •  
5.
  • Benkestock, Kurt, et al. (författare)
  • On-line microdialysis for enhanced resolution and sensitivity during electrospray mass spectrometry of non-covalent complexes and competitive binding studies
  • 2002
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 16:21, s. 2054-2059
  • Tidskriftsartikel (refereegranskat)abstract
    • Many proteins and macromolecules easily form metal adduct ions which impairs their analysis by mass spectrometry. The present study describes how the formation of undesired adducts can be minimized by on-line microdialysis for non-covalent binding studies of macromolecules with low molecular mass ligands with electrospray ionization mass spectrometry (ESI-MS). The technique was indispensable for protein-ligand studies due to reduction of unwanted adduct ions, and thus gave excellent resolution and a sensitivity improvement of at least 5 times. The core of the analytical system was a modified microdialysis device, which was operated in countercurrent mode. A novel technique based on microdialysis for competitive binding studies is also presented. The noncovalent complex between a protein and a ligand was formed in the sample vial prior to analysis. The complex was injected into an on-line microdialysis system where a competitive ligand was administered in the dialysis buffer outside of the fiber. The second ligand competitively displaced the first ligand through transport via the wall of the dialysis fiber, and the intact complexes were detected by ESI-MS.
  •  
6.
  • Björklund, Jonas, et al. (författare)
  • Selective determination of organophosphate flame-retardants and plasticizers in indoor air by gas chromatography, positive-ion chemical ionization and collision-induced dissosiation mass spectrometry
  • 2004
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 18:24, s. 3079-3083
  • Tidskriftsartikel (refereegranskat)abstract
    • Gas chromatography/ion trap mass spectrometry with in-source ionization and dissociation was used in positive-ion chemical ionization (PICI) mode for the determination of organophosphate triesters in indoor air. These compounds are widely used as additive flame retardants and plasticizers in different types of materials and have become ubiquitous pollutants in indoor environments. When using collision-induced dissociation in PICI mode the fragmentation of the organophosphate triesters can be performed in a more controllable way than in electron ionization (EI) mode. The developed selected-reaction monitoring method provided high selectivity for the investigated compounds. For 8-h air measurements (corresponding to 1.5 m3 of sampled air) the limit of detection of the method was determined to be in the range 0.1–1.4 ng m−3, which is comparable with nitrogen-phosphorus detection and about 50-fold lower than when using EI in selected-ion monitoring mode. The presented method was applied to samples from three common indoor environments, in which a number of organophosphate triesters were identified and quantified. The dominating compound was found to be tris(2-chloropropyl) phosphate, which occurred at levels up to 0.8 μg m−3.
  •  
7.
  • Boström, Emma, et al. (författare)
  • The Use of Liquid Chromatography/Mass Spectrometry for Quantitative Analysis of Oxycodone, Oxymorphone and Noroxycodone in Ringer Solution, Rat Plasma and Rat Brain Tissue
  • 2004
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 18:21, s. 2565-2576
  • Tidskriftsartikel (refereegranskat)abstract
    • Sensitive and reproducible methods for the determination of oxycodone, oxymorphone and noroxycodone in Ringer solution, rat plasma and rat brain tissue by liquid chromatography/mass spectrometry are described. Deuterated analogs of the substances were used as internal standards. Samples in Ringer solution were analyzed by direct injection of 10 microL Ringer solution diluted by an equal volume of water. The limit of quantification was 0.5 ng/mL and the method was linear in the range of 0.5-150 ng/mL for all substances. To analyze oxycodone and oxymorphone in rat plasma, 50 microL of plasma were precipitated with acetonitrile, and the supernatant was directly injected onto the column. To analyze oxycodone, oxymorphone and noroxycodone in rat plasma, 100 microL of rat plasma were subjected to a C18 solid-phase extraction (SPE) procedure, before reconstituting in mobile phase and injection onto the column. For both methods the limit of quantification in rat plasma was 0.5 ng/mL and the methods were linear in the range of 0.5-250 ng/mL for all substances. To analyze the content of oxycodone, oxymorphone and noroxycodone in rat brain tissue, 100 microL of the brain homogenate supernatant were subjected to a C18 SPE procedure. The limit of quantification of oxycodone was 20 ng/g brain, and for oxymorphone and noroxycodone 4 ng/g brain, and the method was linear in the range of 20-1000 ng/g brain for oxycodone and 4-1000 ng/g brain for oxymorphone and noroxycodone. All methods utilized a mobile phase of 5 mM ammonium acetate in 45% acetonitrile, and a SB-CN column was used for separation. The total run time of all methods was 9 min. The intra-day precision and accuracy were <11.3% and <+/-14.9%, respectively, and the inter-day precision and accuracy were <14.9% and <+/-6.5%, respectively, for all the concentrations and matrices described.
  •  
8.
  • Fred, Charlotta, et al. (författare)
  • Adducts to N-terminal valines in hemoglobin from isoprene di-epoxide, a metabolite of isoprene
  • 2004
  • Ingår i: Rapid Communications in Mass Spectrometry. - : John Wiley & Sons, Inc. - 0951-4198 .- 1097-0231. ; 18:18, s. 2177-2184
  • Tidskriftsartikel (refereegranskat)abstract
    • Isoprene (2-methylbuta-1,3-diene) is a multi-site carcinogen in rodents. To evaluate the role of the diepoxide metabolite (1,2:3,4-diepoxy-2-methylbutane) in carcinogenesis, measurements of in vivo doses of the diepoxide are needed. The in vivo dose may be inferred from levels of reaction products with hemoglobin (Hb adducts). This report presents in vitro studies of the adduct formation by the diepoxide of isoprene with valinamide and oligopeptides as model compounds of N-terminal valines in hemoglobin (Hb). In the reaction with valinamide it was shown that isoprene diepoxide forms as the main product a ring-closed adduct, which is a pyrrolidine derivative [N,N-(2,3-dihydroxy-2-methyl-1,4-butadiyl)valinamide, MPyr-Val]. The analysis was performed by gas chromatography/mass spectrometry (GC/MS) (EI and PICI) after acetylation. The ring-closed adduct was also identified by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) as the main product in the reaction between isoprene diepoxide and standard hepta- or (2H8)octapeptides, corresponding to the N-terminal peptides of the α-chains in mouse and rat Hb. These peptides, alkylated with isoprene diepoxide, to be used as internal standards and calibration standards for quantification of MPyr-adduct levels in vitro and in vivo, were analyzed with respect to the degree of MPyr-alkylation by two independent methods, amino acid analysis and HPLC-UV; similar results were obtained using these methods. A method for measurement of Hb adducts as modified peptides, used earlier to measure a similar adduct to N-terminal valines in Hb from the diepoxide of 1,3-butadiene, has in the present work been tested for application to isoprene diepoxide. The method is based on tryptic degradation of globin and LC/ESI-MS analysis of N-terminal Pyr-heptapeptides of the Hb α-chain enriched by HPLC. MPyr-adduct levels in isoprene diepoxide alkylated hemolysate from mouse erythrocytes incubated with different concentrations of isoprene diepoxide (2 and 10 mM) for 1 h were quantified. The adduct level was about 50 nmol/g α-chain Hb per mM × h. From the adduct levels the rate constant of isoprene diepoxide for reaction with N-terminal valine was calculated to be about 1.6 times faster than for diepoxybutane
  •  
9.
  • Hellman, Ulf, et al. (författare)
  • Easy amino acid sequencing of sulfonated peptides using post-source decay on a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer equipped with a variable voltage reflector
  • 2002
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 16:19, s. 1851-1859
  • Tidskriftsartikel (refereegranskat)abstract
    • Tryptic peptides were labeled with sulfonic acid groups at the N-termini using an improved chemistry. The derivatization was performed in common aqueous buffers on peptides adsorbed onto a ZipTip trade mark C(18), thus allowing simultaneous desalting/concentration of the sample. When only Arg-terminating peptides were considered, the procedure from adsorption onto the ZipTip until analysis by MALDI-PSD took about 10 min and several samples could be worked on in parallel. The resulting improved post-source decay (PSD) fragmentation produced spectra containing only y-ions. PSD amino acid sequencing of underivatized and derivatized synthetic peptides was compared. From the sequence information obtained from derivatized peptides isolated by ion selection from tryptic in-gel digests, a protein was correctly identified which was difficult to analyze from an unclear peptide mass fingerprint analysis. The method was also applied to the identification and localization of phosphorylated Ser and Tyr residues in native and synthetic peptides.
  •  
10.
  •  
11.
  • Kempka, Martin, et al. (författare)
  • Improved method for peak picking in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
  • 2004
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 18:11, s. 1208-1212
  • Tidskriftsartikel (refereegranskat)abstract
    • A method for peak picking for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described. The method is based on the assumption that two sets of ions are formed during the ionization stage, which have Gaussian distributions but different velocity profiles. This gives rise to a certain degree of peak skewness. Our algorithm deconvolutes the peak and utilizes the fast velocity, bulk ion distribution for peak picking. Evaluation of the performance of the new method was conducted using peptide peaks from a bovine serum albumin (BSA) digest, and compared with the commercial peak-picking algorithms Centroid and SNAP. When using the new two-Gaussian algorithm, for strong signals the mass accuracy was equal to or marginally better than the results obtained from the commercial algorithms. However, for weak, distorted peaks, considerable improvement in both mass accuracy and precision was obtained. This improvement should be particularly useful in proteomics, where a lack of signal strength is often encountered when dealing with weakly expressed proteins. Finally, since the new peak-picking method uses information from the entire signal, no adjustments of parameters related to peak height have to be made, which simplifies its practical use.
  •  
12.
  •  
13.
  • Miliotis, Tasso, et al. (författare)
  • Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format.
  • 2002
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 1097-0231 .- 0951-4198. ; 16:2, s. 117-126
  • Tidskriftsartikel (refereegranskat)abstract
    • The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 microm. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded.
  •  
14.
  • Momcilovic, Dane, et al. (författare)
  • Sample preparation effects in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry of partially depolymerised carboxymethyl cellulose
  • 2003
  • Ingår i: Rapid Communications in Mass Spectrometry. - : American Chemical Society (ACS). - 0951-4198 .- 1097-0231. ; 17:11, s. 1107-1115
  • Tidskriftsartikel (refereegranskat)abstract
    • Sample preparation effects in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) of partially depolymerised carboxymethyl cellulose (CMC) have been investigated. The depolymerisation was either enzymatic or acidic. Fractions of enzymatically depolymerised CMC were collected from size-exclusion chromatography (SEC) and further investigated by MALDI-TOFMS. 2,5-Dihydroxybenzoic acid was used as matrix, dissolved in H2O due to the poor solubility of CMC in suitable organic solvents. The samples were dried by two methods, in ambient atmosphere and at reduced pressure. Under reduced pressure the sample spot homogeneity increased. This drying method, however, produced additional adduct peaks in the mass spectra originating from ion exchange on the CMC oligomers. Analysis of CMC could be performed in both negative and positive ion modes. Mass discrimination and variation in ionisation efficiency were demonstrated by comparing mass spectra with SEC data. Measurements of the degree of substitution (DS) were performed on three CMCs with different DS values, which were depolymerised in trifluoroacetic acid. The three CMCs were easily distinguished from one another, but the obtained DS values deviated from the values supplied by the manufacturer.
  •  
15.
  • Momcilovic, Dane, et al. (författare)
  • Sample preparation effects in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry of partially depolymerised methyl cellulose
  • 2003
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 17:11, s. 1116-1124
  • Tidskriftsartikel (refereegranskat)abstract
    • Methyl cellulose (MC) was partially depolymerised and the oligomers thus obtained were studied by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). The depolymerisation was either enzymatic or acidic. Fractions of enzymatically depolymerised MC were collected from size-exclusion chromatography and subjected to a sample preparation investigation. Several MALDI matrices and solvents were evaluated. The results showed that the solvent choice had a significant effect on the measured degree of substitution (DS). Aprotic solvents produced higher DS values, which was most likely due to poor solubility of species with low DS. The obtained signal intensity, however, did not correlate with the solubility but seemed to be more dependent on certain matrix/solvent combinations. All the matrices attempted produced mass spectra with sufficient signal intensity for accurate peak area calculation. The choice of matrix did not have any significant effect on the measured DS. Sample spots obtained from organic solvents had a more homogeneous distribution of the analyte and smaller crystals than those obtained from water. This increased both the reproducibility and peak resolution and in addition the analysis time was shorter. DS measurements were performed on two acidically depolymerised MCs with different nominal DS values. It was easy to distinguish between the two MCs, and the measured DS values agreed well with the values supplied by the manufacturers.
  •  
16.
  • Momcilovic, Dane, et al. (författare)
  • Sample preparation effects in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry of partially depolymerised methyl cellulose
  • 2003
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 1097-0231 .- 0951-4198. ; 17:11, s. 1116-1124
  • Tidskriftsartikel (refereegranskat)abstract
    • Methyl cellulose (MC) was partially depolymerised and the oligomers thus obtained were studied by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). The depolymerisation was either enzymatic or acidic. Fractions of enzymatically depolymerised MC were collected from size-exclusion chromatography and subjected to a sample preparation investigation. Several MALDI matrices and solvents were evaluated. The results showed that the solvent choice had a significant effect on the measured degree of substitution (DS). Aprotic solvents produced higher DS values, which was most likely due to poor solubility of species with low DS. The obtained signal intensity, however, did not correlate with the solubility but seemed to be more dependent on certain matrix/solvent combinations. All the matrices attempted produced mass spectra with sufficient signal intensity for accurate peak area calculation. The choice of matrix did not have any significant effect on the measured DS. Sample spots obtained from organic solvents had a more homogeneous distribution of the analyte and smaller crystals than those obtained from water. This increased both the reproducibility and peak resolution and in addition the analysis time was shorter. DS measurements were performed on two acidically depolymerised MCs with different nominal DS values. It was easy to distinguish between the two MCs, and the measured DS values agreed well with the values supplied by the manufacturers. Copyright © 2003 John Wiley & Sons, Ltd.
  •  
17.
  • Nilsson, Stefan, et al. (författare)
  • A simple and robust conductive graphite coating for sheathless electrospray emitters used in capillary electrophoresis/mass spectrometry
  • 2001
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 15:21, s. 1997-2000
  • Tidskriftsartikel (refereegranskat)abstract
    • A graphite-polyimide mixture was used as a conductive coating for sheathless electrospray emitters. The coating procedure described is simple and inexpensive compared to previously described methods. An investigation of the stability of the conductive coating carried out by electrochemical methods revealed good performances during oxidative stress. In addition, no decrease in emitter performance was seen during continuous electrospray in the positive electrospray mode for two weeks. Fast capillary electrophoresis with attomole sensitivity demonstrated the excellent performance of the described sheathless interface when used in conjunction with an orthogonal time-of-flight mass spectrometer. The overall simplicity, stability and low cost of this type of sheathless emitter make the described approach highly suitable for any on-column coupling of low flow rate separation techniques to a mass spectrometer.
  •  
18.
  • Nilsson, S. L., et al. (författare)
  • Phosphate buffers in capillary electrophoresis/mass spectrometry using atmospheric pressure photo ionization and electrospray ionization
  • 2003
  • Ingår i: Rapid Communication in mass spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 17:20, s. 2267-2272
  • Tidskriftsartikel (refereegranskat)abstract
    • Capillary electrophoresis (CE) has been combined with atmospheric pressure photoionization (APPI) and electrospray ionization (ESI) for mass spectrometric (MS) detection. Separation conditions using potassium phosphate buffer and ammonium formate buffer have been compared for analysis of eleven pharmaceutical bases. The results showed improvements in separation efficiency and peak symmetry when phosphate buffer was used. The low flow in CE may enable utilization of these advances with MS detection. Compared with ESI, the APPI technique provided a cluster-free background. The enhanced signal-to-noise ratio in the total ion current (TIC) and the reduced spectral background indicated that the APPI process is less affected by non-volatile salts in the CE buffers. This results in a wider range of choice of CE buffers in CE/MS analysis when APPI is the ionization method.
  •  
19.
  •  
20.
  • Norlin, Elin, et al. (författare)
  • Nitrogen isotope analysis of ammonium in aqueous solutions using a perfluorosulfonated ionomer membrane for solid-phase microextraction
  • 2003
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 17:9, s. 936-42
  • Tidskriftsartikel (refereegranskat)abstract
    • The use of custom-made solid-phase microextraction (SPME) fibers coated with a perfluorosulfonated ionomer, Nafion®, was investigated for nitrogen isotopic analysis of ammonium in aqueous solutions. Aqueous ammonium was converted to ammonia by addition of a base, followed by absorption from the headspace, desorption in the injection port of a gas chromatograph, and analysis by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Fibers coated with a Nafion tubing were chosen due to a higher fiber-gas distribution constant and a higher Nafion thickness than fibers coated with Nafion solution, both leading to a higher amount of ammonia absorbed at equilibrium. The Nafion membrane-coated fiber absorbed approximately 20 times more than a commercial polydimethylsiloxane (PDMS) fiber. The isotopic fractionation between fiber and gas was 1.0117 ± 0.0009 (standard deviation, SD, of all measurements) at an initial ammonia gas concentration of 21-210 M. At 390 M initial gas concentration it was slightly lower. When sampling from liquid samples, an ammonium concentration of 10 mM was needed to obtain a sufficient amount of ammonia absorbed. Modeling of the absorption at different temperatures showed that the absorption was approximately constant in the temperature range suitable for SPME experiments. Absorption at room temperature was therefore used for simplicity. A pilot study was conducted in which absorption was achieved from a single 9 L droplet of sample. The preliminary results showed that 15N analysis was possible for only 0.4-0.5 mol of ammonium with a SD of 0.8 (n = 5).
  •  
21.
  •  
22.
  • Palmblad, Magnus, et al. (författare)
  • Liquid Chromatography and Electron Capture Dissociation in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
  • 2002
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 16:10, s. 988-992
  • Tidskriftsartikel (refereegranskat)abstract
    • Liquid separation methods in combination with electrospray mass spectrometry as well as the recently introduced fragmentation method electron capture dissociation (ECD) have become powerful tools in proteomics research. This paper presents the results of the first successful attempts to combine liquid chromatography (LC) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with ECD in the analysis of a mixture of standard peptides and of a bovine serum albumin tryptic digest. A novel electron injection system provided conditions for ECD sufficient to yield extensive sequence information for the most abundant peptides in the mixtures on the time-scale of the chromatographic separation. The results suggest that LC/ECD-FTICRMS can be employed in the characterization of peptides in enzymatic digests of proteins or protein mixtures and identify and localize posttranslational modifications.
  •  
23.
  •  
24.
  •  
25.
  • Redeby, Theres, et al. (författare)
  • Simple fabrication of a structured matrix-assisted laser desorption/ionization target coating for increased sensitivity in mass spectrometric analysis of membrane proteins
  • 2004
  • Ingår i: Rapid Communications in Mass Spectrometry. - : Wiley. - 0951-4198 .- 1097-0231. ; 18:10, s. 1161-1166
  • Tidskriftsartikel (refereegranskat)abstract
    • A new prestructured target plate for matrix-assisted laser desorption/ionization (MALDI) was developed specifically for hydrophobic integral membrane proteins. This sample support contains predefined concentrating sample spots with a focusing effect on droplets with a high content of hexafluoroisopropanol (HFIP). This fluorinated organic solvent is advantageous for solubilizing hydrophobic proteins that are not soluble in water or the organic solvents normally used in sample preparation protocols for MALDI-MS. The prestructured plate was constructed by coating a regular steel plate with a thin layer of a silicone polymer, leaving sample spots of bare steel. Fabrication of the concentrating silicone structure was fast and very straightforward, without expensive or complicated equipment. Removing the layer, and thus regenerating the steel plate, was done by a simple washing procedure. The application and cleaning procedure are not constrained by a particular design of sample support or to any specific brand of mass spectrometer. When using the prestructured MALDI plate with HFIP as the sample solvent for 17 pmol of a cyanogen bromide digest of the highly hydrophobic membrane protein bacteriorhodopsin, an improved focusing effect and an increase of more than five-fold in average sensitivity were observed, compared with a regular steel target. Experimental results show a two-fold increase in average sensitivity when the new prestructured target plate was used, compared with a commercially available concentrating support
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-25 av 52
Typ av publikation
tidskriftsartikel (52)
Typ av innehåll
refereegranskat (47)
övrigt vetenskapligt/konstnärligt (5)
Författare/redaktör
Griffiths, WJ (9)
Roeraade, Johan (6)
Bergquist, Jonas (4)
Liu, S. (2)
Törnqvist, Margareta (2)
Hellman, Ulf (2)
visa fler...
Brinkmalm, G (2)
Palmblad, Magnus (2)
Jornvall, H (2)
Karlsson, J. (2)
Nilsson, S. (2)
Markides, Karin (2)
Emmer, Åsa (2)
Kjeldsen, F (2)
Abraham-Nordling, M (1)
Perlmann, T (1)
Boström, Emma (1)
Johansson, J (1)
Gudmundsson, GH (1)
Grunewald, J (1)
Agerberth, B (1)
Kåredal, Monica (1)
Törnqvist, M. (1)
Andersson, C (1)
Brinkmalm, Gunnar (1)
Nilsson, Johan (1)
Andersson, M (1)
Zubarev, Roman A (1)
Budnik, Bogdan A (1)
Haselmann, Kim F (1)
Nyberg, Fred (1)
von Kieseritzky, Fre ... (1)
Hellberg, Jonas (1)
Laurell, Thomas (1)
Karlsson, Johan (1)
Alsberg, T (1)
Hammarlund-Udenaes, ... (1)
Lindh, Christian (1)
Jönsson, Bo A (1)
Jonsson, AP (1)
Bergman, T (1)
Marko-Varga, György (1)
Stemme, Göran (1)
Andrén, Per E. (1)
Bondesson, Ulf (1)
Hedeland, Mikael (1)
Kjellström, Sven (1)
Woldegiorgis, A. (1)
Svedberg, M (1)
Markides, KE (1)
visa färre...
Lärosäte
Uppsala universitet (18)
Karolinska Institutet (16)
Kungliga Tekniska Högskolan (9)
Stockholms universitet (5)
Lunds universitet (4)
Umeå universitet (1)
visa fler...
Mälardalens universitet (1)
Mittuniversitetet (1)
visa färre...
Språk
Engelska (48)
Odefinierat språk (4)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (15)
Teknik (2)
Medicin och hälsovetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy