SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bentley P.M.) srt2:(2015-2019)"

Sökning: WFRF:(Bentley P.M.) > (2015-2019)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alexander, T., et al. (författare)
  • Isomeric Ratios in 206Hg
  • 2015
  • Ingår i: Acta Physica Polonica. Series B: Elementary Particle Physics, Nuclear Physics, Statistical Physics, Theory of Relativity, Field Theory. - 0587-4254. ; 46:3, s. 601-605
  • Tidskriftsartikel (refereegranskat)abstract
    • Hg-206 was populated in the fragmentation of an E/A = 1 GeV Pb-208 beam at GSI. It was part of a campaign to study nuclei around Pb-208 via relativistic Coulomb excitation. The observation of the known isomeric states confirmed the identification of the fragmentation products. The isomeric decays were also used to prove that the correlations between beam identification detectors and the AGATA gamma-ray tracking array worked properly and that the tracking efficiency was independent of the time relative to the prompt flash.
  •  
2.
  • Khaplanov, A., et al. (författare)
  • Neutron beam monitors for the European spallation source
  • 2015
  • Ingår i: 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781467398626
  • Konferensbidrag (refereegranskat)abstract
    • The European Spallation Source (ESS), currently under construction in Lund, Sweden, will house a suite of 16 user instruments for neutron scattering experiments. The spallation source of the ESS will emit relatively long, 2.8 ms, neutron pulses with an integrated flux that will greatly exceed that of current facilities. This leads to both large advancements in instrument performance as well as to increased length and complexity of the beam delivery systems. The instruments will each be equipped with neutron beam monitors used for data normalisation and analysis, as well as commissioning and diagnostics. In this paper we present the requirements for beam monitors for the ESS and the strategy to meet these in a standardised approach. A large range of specifications in efficiency, dynamic range, time and position resolution, compatible materials are needed. A new feature for neutron beam monitors for some locations, is the ability to measure time profile of each source pulse individually. In general, event mode readout will be used for monitors, similarly to other neutron detectors at the facility. A selection of detectors based on different technologies will be available. Monitors will be integrated with beam lines and choppers in a way that allows to freely choose the type of monitor based on final requirements of an instrument. For this end, space for a standardised module, housing a monitor will be provided in conjunction with chopper assemblies and elsewhere on each beam line.
  •  
3.
  • Maier, O., et al. (författare)
  • ISLES 2015-A public evaluation benchmark for ischemic stroke lesion segmentation from multispectral MRI
  • 2017
  • Ingår i: Medical Image Analysis. - : Elsevier BV. - 1361-8415 .- 1361-8423. ; 35, s. 250-269
  • Tidskriftsartikel (refereegranskat)abstract
    • Ischemic stroke is the most common cerebrovascular disease, and its diagnosis, treatment, and study relies on non-invasive imaging. Algorithms for stroke lesion segmentation from magnetic resonance imaging (MRI) volumes are intensely researched, but the reported results are largely incomparable due to different datasets and evaluation schemes. We approached this urgent problem of comparability with the Ischemic Stroke Lesion Segmentation (ISLES) challenge organized in conjunction with the MICCAI 2015 conference. In this paper we propose a common evaluation framework, describe the publicly available datasets, and present the results of the two sub-challenges: Sub-Acute Stroke Lesion Segmentation (SISS) and Stroke Perfusion Estimation (SPES). A total of 16 research groups participated with a wide range of state-of-the-art automatic segmentation algorithms. A thorough analysis of the obtained data enables a critical evaluation of the current state-of-the-art, recommendations for further developments, and the identification of remaining challenges. The segmentation of acute perfusion lesions addressed in SPES was found to be feasible. However, algorithms applied to sub-acute lesion segmentation in SISS still lack accuracy. Overall, no algorithmic characteristic of any method was found to perform superior to the others. Instead, the characteristics of stroke lesion appearances, their evolution, and the observed challenges should be studied in detail. The annotated ISLES image datasets continue to be publicly available through an online evaluation system to serve as an ongoing benchmarking resource (www.isles-challenge.org).
  •  
4.
  • Santoro, V., et al. (författare)
  • Study of neutron shielding collimators for curved beamlines at the European Spallation Source
  • 2018. - 1
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 1046
  • Konferensbidrag (refereegranskat)abstract
    • The European Spallation Source is being constructed in Lund, Sweden and is planned to be the world's brightest pulsed spallation neutron source for cold and thermal neutron beams (≤ 1 eV). The facility uses a 2 GeV proton beam to produce neutrons from a tungsten target. The neutrons are then moderated in a moderator assembly consisting of both liquid hydrogen and water compartments. Surrounding the moderator are 22 beamports, which view the moderator's outside surfaces. The beamports are connected to long neutron guides that transport the moderated neutrons to the sample position via reflections. As well as the desired moderated neutrons, fast neutrons coming directly from the target can find their way down the beamlines. These can create unwanted sources of background for the instruments. To mitigate such a kind of background, several instruments will use curved guides to lose direct line-of-sight (LoS) to the moderator and the target. In addition instruments can also use shielding collimators to reduce the amount of fast neutrons further traveling down the guide due to albedo reflections or streaming. Several different materials have been proposed for this purpose. We present the results of a study of different options for collimators and identify the optimal choices that balance cost, background and activation levels.
  •  
5.
  • Zendler, Carolin, et al. (författare)
  • Generic guide concepts for the European Spallation Source
  • 2015
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 803, s. 89-99
  • Tidskriftsartikel (refereegranskat)abstract
    • The construction of the European Spoliation Source (ESS) faces many challenges from the neutron beam transport point of view: the spoliation source is specified as being driven by a 5 MW beam of protons, each with 2 GeV energy, and yet the requirements in instrument background suppression relative to measured signal vary between 10(-6) and 10(-8). The energetic particles, particularly above 20 MeV, which are expected to be produced in abundance in the target, have to be filtered in order to make the beamlines safe, operational and provide good quality measurements with low background. We present generic neutron guides of short and medium length instruments which are optimised for good performance at minimal cost. Direct line of sight to the source is avoided twice, with either the first point out of line of sight or both being inside the bunker (20 m) to minimise shielding costs. These guide geometries are regarded as a baseline to define standards for instruments to be constructed at ESS. They are used to find commonalities and develop principles and solutions for common problems. Lastly, we report the impact of employing the over-illumination concept to mitigate losses from random misalignment passively, and that over-illumination should be used sparingly in key locations to be effective. For more widespread alignment issues, a more direct, active approach is likely to be needed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy