SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Erduran N.) srt2:(2015-2019)"

Sökning: WFRF:(Erduran N.) > (2015-2019)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Jaworski, G., et al. (författare)
  • The New Neutron Multiplicity Filter NEDA and Its First Physics Campaign with AGATA
  • 2019
  • Ingår i: Acta Physica Polonica B. - 0587-4254 .- 1509-5770. ; 50:3, s. 585-590
  • Tidskriftsartikel (refereegranskat)abstract
    • A new neutron multiplicity filter NEDA, after a decade of design, R&D and construction, was employed in its first physics campaign with the AGATA spectrometer. Properties and performance of the array are discussed.
  •  
2.
  • Söderström, Pär-Anders, 1980-, et al. (författare)
  • Neutron detection and gamma-ray suppression using artificial neural networks with the liquid scintillators BC-501A and BC-537
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : ELSEVIER SCIENCE BV. - 0168-9002 .- 1872-9576. ; 916, s. 238-245
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work we present a comparison between the two liquid scintillators BC-501A and BC-537 in terms of their performance regarding the pulse-shape discrimination between neutrons and gamma rays. Special emphasis is put on the application of artificial neural networks. The results show a systematically higher gamma-ray rejection ratio for BC-501A compared to BC-537 applying the commonly used charge comparison method. Using the artificial neural network approach the discrimination quality was improved to more than 95% rejection efficiency of gamma rays over the energy range 150 to 1000 keV for both BC-501A and BC-537. However, due to the larger light output of BC-501A compared to BC-537, neutrons could be identified in BC-501A using artificial neural networks down to a recoil proton energy of 800 keV compared to a recoil deuteron energy of 1200 keV for BC-537. We conclude that using artificial neural networks it is possible to obtain the same gamma-ray rejection quality from both BC-501A and BC-537 for neutrons above a low-energy threshold. This threshold is, however, lower for BC-501A, which is important for nuclear structure spectroscopy experiments of rare reaction channels where low-energy interactions dominates.
  •  
3.
  • Valiente-Dobon, J. J., et al. (författare)
  • NEDA-NEutron Detector Array
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 927, s. 81-86
  • Tidskriftsartikel (refereegranskat)abstract
    • The NEutron Detector Array, NEDA, will form the next generation neutron detection system that has been designed to be operated in conjunction with gamma-ray arrays, such as the tracking-array AGATA, to aid nuclear spectroscopy studies. NEDA has been designed to be a versatile device, with high-detection efficiency, excellent neutron-gamma discrimination, and high rate capabilities. It will be employed in physics campaigns in order to maximise the scientific output, making use of the different stable and radioactive ion beams available in Europe. The first implementation of the neutron detector array NEDA with AGATA 1 pi was realised at GANIL. This manuscript reviews the various aspects of NEDA.
  •  
4.
  • Egea Canet, F. J., et al. (författare)
  • A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
  • 2015
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:3, s. 1056-1062
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
  •  
5.
  • Egea Canet, F. J., et al. (författare)
  • Digital Front-End Electronics for the Neutron Detector NEDA
  • 2015
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:3, s. 1063-1069
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the design of the NEDA (Neutron Detector Array) electronics, a first attempt to involve the use of digital electronics in large neutron detector arrays. Starting from the front-end modules attached to the PMTs (PhotoMultiplier Tubes) and ending up with the data processing workstations, a comprehensive electronic system capable of dealing with the acquisition and pre-processing of the neutron array is detailed. Among the electronic modules required, we emphasize the front-end analog processing, the digitalization, digital pre-processing and communications firmware, as well as the integration of the GTS (Global Trigger and Synchronization) system, already used successfully in AGATA (Advanced Gamma Tracking Array). The NEDA array will be available for measurements in 2016.
  •  
6.
  • Luo, X. L., et al. (författare)
  • Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors
  • 2018
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : ELSEVIER SCIENCE BV. - 0168-9002 .- 1872-9576. ; 897, s. 59-65
  • Tidskriftsartikel (refereegranskat)abstract
    • The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and.. standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigated as a function of the time interval between two pulses constituting a pile-up event. The obtained results show that the method is capable of disentangling two pulses with a time interval among them down to 20 ns, as well as classifying them as neutrons or gamma rays. Furthermore, the error of reconstructing pile-up pulses could be kept below 6% when successive peaks were separated by more than 50 ns. By applying the method in a high counting rate of pile-up events measurement of the NEutron Detector Array (NEDA), it was empirically found that this method can reconstruct the pile-up pulses and perform neutron-gamma discrimination quite accurately. It can also significantly correct the distorted pulse height spectrum due to pile-up events.
  •  
7.
  • Modamio, V., et al. (författare)
  • Digital pulse-timing technique for the neutron detector array NEDA
  • 2015
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 775, s. 71-76
  • Tidskriftsartikel (refereegranskat)abstract
    • A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes.
  •  
8.
  • Sahin, E., et al. (författare)
  • Shell evolution beyond N=40 : Cu-69,Cu-71,Cu-73
  • 2015
  • Ingår i: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 91:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The level structure of the neutron-rich Cu-69, Cu-71, and Cu-73 isotopes has been investigated by means of multinucleon transfer reactions. The experiment was performed at Laboratori Nazionali di Legnaro using the AGATA Demonstrator array coupled to the PRISMA magnetic spectrometer. Lifetimes of excited states in Cu nuclei were measured with the recoil-distance Doppler-shift method. The resulting electromagnetic matrix elements for transitions from excited states in Cu-69,Cu-71,Cu-73 nuclei are used to assess the collective or single-particle character of these states. The results are compared with predictions of large-scale shell-model calculations, giving further insight into the evolution of the proton pf shell as neutrons fill the 1g(9/2) orbital.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy