SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Espada Daniel) srt2:(2015-2019)"

Sökning: WFRF:(Espada Daniel) > (2015-2019)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Behrendt, Christian-Alexander, et al. (författare)
  • Editor's Choice - Recommendations for Registry Data Collection for Revascularisations of Acute Limb Ischaemia : A Delphi Consensus from the International Consortium of Vascular Registries
  • 2019
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : W B SAUNDERS CO LTD. - 1078-5884 .- 1532-2165. ; 57:6, s. 816-821
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To develop a minimum core data set for evaluation of acute limb ischaemia (ALI) revascularisation treatment and outcomes that would enable collaboration among international registries. Methods: A modified Delphi approach was used to achieve consensus among international multidisciplinary vascular specialists and registry members of the International Consortium of Vascular Registries (ICVR). Variables identified in the literature or suggested by the expert panel, and variables, including definitions, currently used in 15 countries in the ICVR, were assessed to define both a minimum core and an optimum data set to register ALI treatment. Clinical relevance and practicability were both assessed, and consensus was defined as >= 80% agreement among participants. Results: Of 40 invited experts, 37 completed a preliminary survey and 31 completed the two subsequent Delphi rounds via internet exchange and face to face discussions. In total, 117 different items were generated from the various registry data forms, an extensive review of the literature, and additional suggestions from the experts, for potential inclusion in the data set. Ultimately, 35 items were recommended for inclusion in the minimum core data set, including 23 core items important for all registries, and an additional 12 more specific items for registries capable of capturing more detail. These 35 items supplement previous data elements recommended for registering chronic peripheral arterial occlusive disease treatment. Conclusion: A modified Delphi study allowed 37 international vascular registry experts to achieve a consensus recommendation for a minimum core and an optimum data set for registries covering patients who undergo ALI revascularisation. Continued global harmonisation of registry infrastructure and definition of items allows international comparisons and global quality improvement. Furthermore, it can help to define and monitor standards of care and enable international research collaboration.
  •  
2.
  • Fathi, Kambiz, et al. (författare)
  • LOCAL INSTABILITY SIGNATURES IN ALMA OBSERVATIONS OF DENSE GAS IN NGC 7469
  • 2015
  • Ingår i: Astrophysical Journal Letters. - 2041-8205 .- 2041-8213 .- 1538-4357 .- 0004-637X. ; 806:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present an unprecedented measurement of the disk stability and local instability scales in the luminous infrared Seyfert 1 host, NGC 7469, based on ALMA observations of dense gas tracers and with a synthesized beam of 165 x 132 pc. While we confirm that non-circular motions are not significant in redistributing the dense interstellar gas in this galaxy, we find compelling evidence that the dense gas is a suitable tracer for studying the origin of its intensely high-mass star-forming ringlike structure. Our derived disk stability parameter Q accounts for a thick disk structure, and its value falls below unity at the radii in which intense star formation is found. Furthermore, we derive the characteristic instability scale lambda(c) and find a striking agreement between our measured scale of similar to 180 pc and the typical sizes of individual complexes of young and massive star clusters seen in high-resolution images.
  •  
3.
  • Izumi, Takuma, et al. (författare)
  • ALMA OBSERVATIONS OF THE SUBMILLIMETER DENSE MOLECULAR GAS TRACERS IN THE LUMINOUS TYPE-1 ACTIVE NUCLEUS OF NGC 7469
  • 2015
  • Ingår i: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 811:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We present Atacama Large Millimeter/submillimeter Array (ALMA) Cycle 1 observations of the central kiloparsec region of the luminous type. 1 Seyfert galaxy NGC 7469 with unprecedented high resolution (0.'' 5x0.'' 4 = 165 x 132 pc) at submillimeter wavelengths. Utilizing the wide. bandwidth of ALMA, we simultaneously obtained HCN(4-3), HCO+(4-3), CS(7-6), and partially CO(3-2) line maps, as well as the 860 mu m continuum. The region consists of the central similar to 1 '' component and the surrounding starburst ring with a radius of similar to 1.'' 5-2.'' 5. Several structures connect these components. Except for CO(3-2), these dense gas tracers are significantly concentrated toward the central similar to 1 '', suggesting their suitability to probe the nuclear regions of galaxies. Their spatial distribution resembles well those of centimeter and mid-infrared continuum emissions, but it is anticorrelated with the optical one, indicating the existence of dust-obscured star formation. The integrated intensity ratios of HCN(4-3)/HCO+(4-3) and HCN(4-3)/CS(7-6) are higher at the active galactic nucleus (AGN) position than at the starburst ring, which is consistent with our previous findings (submillimeter-HCN enhancement). However, the HCN(4-3)/HCO+(4-3) ratio at the AGN position of NGC 7469 (1.11 +/- 0.06) is almost half of the corresponding value of the low-luminosity type. 1 Seyfert galaxy NGC 1097 (2.0 +/- 0.2), despite the more than two orders of magnitude higher X-ray luminosity of NGC 7469. But the ratio is comparable to that of the close vicinity of the AGN of NGC 1068 (similar to 1.5). Based on these results, we speculate that some heating mechanisms other than X-ray (e.g., mechanical heating due to an AGN jet) can contribute significantly for shaping the chemical composition in NGC 1097.
  •  
4.
  • Izumi, Takuma, et al. (författare)
  • SUBMILLIMETER-HCN DIAGRAM FOR ENERGY DIAGNOSTICS IN THE CENTERS OF GALAXIES
  • 2016
  • Ingår i: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 818:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Compiling data from literature and the Atacama Large Millimeter/submillimeter Array archive, we show enhanced HCN(4-3)/HCO+(4-3) and/or HCN(4-3)/CS(7-6) integrated intensity ratios in circumnuclear molecular gas around active galactic nuclei (AGNs) compared to those in starburst (SB) galaxies (submillimeter HCN. enhancement). The number of sample galaxies is significantly increased from our previous work. We expect that this feature could potentially be an extinction-free energy diagnostic tool of nuclear regions of galaxies. Non-LTE radiative transfer modelings of the above molecular emission lines involving both collisional and radiative excitation, as well as a photon trapping effect, were conducted to investigate the cause of the high line ratios in AGNs. As a result, we found that enhanced abundance ratios of HCN to HCO+ and HCN to CS in AGNs as compared to SB galaxies by a factor of a few to even greater than or similar to 10 are a plausible explanation for the submillimeter HCN. enhancement. However, a counterargument of a systematically higher gas density in AGNs than in SB galaxies can also be a plausible scenario. Although we cannot fully distinguish. these two scenarios at this moment owing to an insufficient amount of multi-transition, multi-species data, the former scenario is indicative of abnormal chemical composition in AGNs. Regarding the actual mechanism to realize the composition, we suggest that it is difficult with conventional gas-phase X-ray-dominated region ionization models to reproduce the observed high line ratios. We might have to take into account other mechanisms such as neutral-neutral reactions that are efficiently activated in high-temperature environments and/or mechanically heated regions to further understand the high line ratios in AGNs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy