SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Esteve F) srt2:(2005-2009)"

Sökning: WFRF:(Esteve F) > (2005-2009)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Forsen, E, et al. (författare)
  • Ultrasensitive mass sensor fully integrated with complementary metal-oxide-semiconductor circuitry
  • 2005
  • Ingår i: Applied Physics Letters. - : AIP Publishing. - 0003-6951 .- 1077-3118. ; 87:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Nanomechanical resonators have been monolithically integrated on preprocessed complementary metal-oxide-semiconductor (CMOS) chips. Fabricated resonator systems have been designed to have resonance frequencies up to 1.5 MHz. The systems have been characterized in ambient air and vacuum conditions and display ultrasensitive mass detection in air. A mass sensitivity of 4 ag/Hz has been determined in air by placing a single glycerine drop, having a measured weight of 57 fg, at the apex of a cantilever and subsequently measuring a frequency shift of 14.8 kHz. CMOS integration enables electrostatic excitation, capacitive detection, and amplification of the resonance signal directly on the chip.
  •  
3.
  • Ghatnekar-Nilsson, Sara, et al. (författare)
  • Resonators with integrated CMOS circuitry for mass sensing applications, fabricated by electron beam lithography
  • 2005
  • Ingår i: Nanotechnology. - : IOP Publishing. - 0957-4484 .- 1361-6528. ; 16:1, s. 98-102
  • Tidskriftsartikel (refereegranskat)abstract
    • A resonator system has been fabricated directly on a pre-processed CMOS chip. The system is to be used for high sensitivity mass sensing applications in air and vacuum. The resonator system, corresponding of a cantilever and structures for electrostatic actuation and capacitive read-out, have been defined by electron beam lithography on top of a charge and radiation sensitive CMOS layer in predefined areas as a post-process step. This has been accomplished without affecting the electronic properties of the pre-processed CMOS circuits. The subsequent etching steps to fully release the cantilevers have been obtained without stiction of the cantilevers to the substrate. Cantilevers are driven at their mechanical resonance in a lateral mode, and the frequency is monitored by capacitive read-out on the chip. CMOS integration enables signal detection directly on the chip, which radically decreases the parasitic capacitances. Consequently, low-noise electrical measurements with a very high mass sensitivity are obtained. Fabricated resonator systems were characterized to have resonance frequencies of approximately 1.49 MHz, which is in good agreement with a theoretical estimation of 1.41 MHz. The theoretical mass resolution, partial derivativem/partial derivativef, is approximately 17 ag Hz(-1) using a Young modulus value of 160 GPa.
  •  
4.
  • Estrada, EJ, et al. (författare)
  • Combined treatment of intrapancreatic autologous bone marrow stem cells and hyperbaric oxygen in type 2 diabetes mellitus
  • 2008
  • Ingår i: Cell transplantation. - : SAGE Publications. - 0963-6897 .- 1555-3892. ; 17:12, s. 1295-1304
  • Tidskriftsartikel (refereegranskat)abstract
    • The objective of this study was to determine whether the combination therapy of intrapancreatic autologous stem cell infusion (ASC) and hyperbaric oxygen treatment (HBO) before and after ASC can improve islet function and metabolic control in patients with type 2 diabetes mellitus (T2DM). This prospective phase 1 study enrolled 25 patients with T2DM who received a combination therapy of intrapancreatic ASC and periinfusion HBO between March 2004 and October 2006 at Stem Cells Argentina Medical Center Buenos Aires, Argentina. Clinical variables (body mass index, oral hypoglycemic drugs, insulin requirement) and metabolic variables (fasting plasma glucose, C-peptide, HbA1c, and calculation of C-peptide/glucose ratio) were assessed over quartile periods starting at baseline and up to 1 year follow-up after intervention. Means were calculated in each quartile period and compared to baseline. Seventeen male and eight female patients were enrolled. Baseline variables expressed as means ± SEs were: age 55 ± 2.14 years, diabetes duration 13.2 ± 1.62 years, insulin dose 34.8 ± 2.96 U/day, and BMI 27.11 ± 0.51. All metabolic variables showed significant improvement when comparing baseline to 12 months follow-up, respectively: fasting glucose 205.6 ± 5.9 versus 105.2 ± 14.2 mg/dl, HbA1c 8.8 ± 0.2 versus 6.0 ± 0.4%, fasting C-peptide 1.5 ± 0.2 versus 3.3 ± 0.3 ng/ml, C-peptide/glucose ratio 0.7 ± 0.2 versus 3.5 ± 0.3, and insulin requirements 34.8 ± 2.9 versus 2.5 ± 6.7 U/day. BMI remained constant over the 1-year follow-up. Combined therapy of intrapancreatic ASC infusion and HBO can improve metabolic control and reduce insulin requirements in patients with T2DM. Further randomized controlled clinical trials will be required to confirm these findings.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy