SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Frerichs H.)
 

Sökning: WFRF:(Frerichs H.) > (2021) > Model Selection Bas...

Model Selection Based Algorithm in Neonatal Chest EIT

Seifnaraghi, Nima (författare)
Middlesex University, UK
de Gelidi, Serena (författare)
Middlesex University, UK
Nordebo, Sven, 1963- (författare)
Linnéuniversitetet,Institutionen för fysik och elektroteknik (IFE)
visa fler...
Kallio, Merja (författare)
University of Oulu, Finland;Oulu University Hospital, Finland
Frerichs, Inez (författare)
University Medical Centre Schleswig-Holstein, Germany
Tizzard, Andrew (författare)
Middlesex University, UK
Suo-Palosaari, Maria (författare)
University of Oulu, Finland;Oulu University Hospital, Finland
Sophocleous, Louiza (författare)
University of Cyprus, Cyprus
van Kaam, Anton H. (författare)
Amsterdam University Medical Centres, Neherlands
Sorantin, Erich (författare)
Medical University of Graz, Austria
Demosthenous, Andreas (författare)
University College London, UK
Bayford, Richard H. (författare)
Middlesex University, UK
visa färre...
 (creator_code:org_t)
IEEE, 2021
2021
Engelska.
Ingår i: IEEE Transactions on Biomedical Engineering. - : IEEE. - 0018-9294 .- 1558-2531. ; 68:9, s. 2752-2763
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper presents a new method for selecting a patient specific forward model to compensate for anatomical variations in electrical impedance tomography (EIT) monitoring of neonates. The method uses a combination of shape sensors and absolute reconstruction. It takes advantage of a probabilistic approach which automatically selects the best estimated forward model fit from pre-stored library models. Absolute/static image reconstruction is performed as the core of the posterior probability calculations. The validity and reliability of the algorithm in detecting a suitable model in the presence of measurement noise is studied with simulated and measured data from 11 patients. The paper also demonstrates the potential improvements on the clinical parameters extracted from EIT images by considering a unique case study with a neonate patient undergoing computed tomography imaging as clinical indication prior to EIT monitoring. Two well-known image reconstruction techniques, namely GREIT and tSVD, are implemented to create the final tidal images. The impacts of appropriate model selection on the clinical extracted parameters such as center of ventilation and silent spaces are investigated. The results show significant improvements to the final reconstructed images and more importantly to the clinical EIT parameters extracted from the images that are crucial for decision-making and further interventions.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Tomography
Pediatrics
Electrodes
Imaging
Conductivity
Image reconstruction
Lung
Electrical impedance tomography
model selection
neonatal chest EIT
patient-specific prior model
thorax modelling
Electrotechnology
Elektroteknik alt Electrical engineering

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy