SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hutton B) srt2:(1990-1994)"

Sökning: WFRF:(Hutton B) > (1990-1994)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hutton, R, et al. (författare)
  • Photon spectroscopy following electron-capture for the collision systems 10 keV/q Kr(q+) + He (q=7,8,9)
  • 1993
  • Ingår i: Physica Scripta. - 0031-8949. ; 48:5, s. 569-572
  • Tidskriftsartikel (refereegranskat)abstract
    • Spectral studies following electron capture in slow ion-atom collisions are reported for the collision systems Kr(q+) + He (q = 7, 8, 9) at 10 keV/q. The work introduces part of the spectroscopy program which is beginning at the University of Uppsala ECR ion source facility. In particular a search was made for the 3d(10)4p2P-3d(9)4S(2)2D transitions in Cu-like Kr. This multiplet was found to give transitions with wavelengths 198.56, 194.65 and 190.97 angstrom for the 3/2-5/2, 3/2-3/2 and 1/2-3/2 components respectively.
  •  
2.
  • Sorensen, S.L., et al. (författare)
  • A normal-incidence beam line at the MAX storage ring
  • 1990
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0168-9002. ; 297:1-2, s. 296-300
  • Tidskriftsartikel (refereegranskat)abstract
    • A 1-m normal-incidence monochromator has been designed and installed on a bending-magnet beam line at the MAX storage ring in Lund. The optical properties of the beam line have been investigated via ray-tracing studies and with flux measurements of the beam line-monochromator combination. A resolution of 0.9 Å at 919.8 Å was measured in first-order diffraction with an argon hollow-cathode lamp for slit openings of 100 μm. A photon flux of 2.0 × 1010 at 550 Å with 250 μm slits was measured with a calibrated GaAs photodiode through a 1.5-mm diameter aperture in an aluminum mask on the photodiode. The new instrument has a microcomputer controlled mechanism which optimizes focussing requirements for a scanning monochromator with the requirement of fixed slits and fixed exit beam.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy