SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Johansen Jens Brock)
 

Sökning: WFRF:(Johansen Jens Brock) > (2020) > Development of the ...

Development of the Implantable Cardioverter Defibrillator Body Image Concerns Questionnaire

Frydensberg, Vivi Skibdal (författare)
Univ Southern Denmark, Denmark; Odense Univ Hosp, Denmark; Odense Patient Data Explorat Network OPEN, Denmark
Strömberg, Anna, 1967- (författare)
Linköpings universitet,Avdelningen för omvårdnad och reproduktiv hälsa,Medicinska fakulteten,Region Östergötland, Kardiologiska kliniken US
Johansen, Jens Brock (författare)
Odense Univ Hosp, Denmark
visa fler...
Pedersen, Susanne S. (författare)
Univ Southern Denmark, Denmark; Odense Univ Hosp, Denmark; Univ Southern Denmark, Denmark
visa färre...
 (creator_code:org_t)
LIPPINCOTT WILLIAMS & WILKINS, 2020
2020
Engelska.
Ingår i: Journal of Cardiovascular Nursing. - : LIPPINCOTT WILLIAMS & WILKINS. - 0889-4655 .- 1550-5049. ; 35:2, s. 165-183
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background The implantable cardioverter defibrillator (ICD) is the first-line treatment for the prevention of sudden cardiac death. Although most ICD recipients adapt well to living with the device, some struggle with ICD-related body image concerns (BICs). Because of lack of standardized questionnaires to assess BICs, we do not know the prevalence. Objective The aim of this study was to develop a questionnaire that assesses self-reported ICD-related BICs. Methods Using a sequential, qualitative multimethod approach, we developed the ICD-BIC questionnaire (ICD-BICQ) based on (1) themes from a scoping review on BICs in ICD recipients, (2) cognitive interviews with ICD recipients to evaluate the validity of items and to ascertain whether items were missing, and (3) input from healthcare professionals. A conceptual framework was created containing 4 general dimensions: (1) assessment, (2) behavior, (3) body perception, and (4) emotions. Results Implantable cardioverter defibrillator recipients (n = 8, 2 women and 6 men; age, 40-78 years), 2 specialists in questionnaire development, and healthcare professionals specialized in ICD treatment evaluated the questionnaire. After no new items or new dimensions emerged from the cognitive interviews, the final version 7 of the ICD-BICQ consisted of 39 items tapping into (1) assessment (n = 2), (2) behavior (n = 13), (3) body perception (n = 16), and emotions (n = 8). Items were assessed on a 5-point Likert-type scale. Conclusion Using patient and healthcare professionals involvement, we developed the 39-item ICD-BICQ to measure the prevalence of BICs in ICD recipients. The factor structure, construct validity, psychometric properties, and a clinically relevant cutoff for the ICD-BICQ will be evaluated in a quantitative study of ICD recipients.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Omvårdnad (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Nursing (hsv//eng)

Nyckelord

body image; defibrillators; implantable; patient-reported outcomes; questionnaire design

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy