SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kennebäck Göran) srt2:(2015-2019)"

Sökning: WFRF:(Kennebäck Göran) > (2015-2019)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Albåge, Anders, et al. (författare)
  • Long-Term Risk of Ischemic Stroke After the Cox-Maze III Procedure for Atrial Fibrillation
  • 2017
  • Ingår i: Annals of Thoracic Surgery. - : Elsevier BV. - 0003-4975 .- 1552-6259. ; 104:2, s. 523-529
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The long-term risk of stroke after surgical treatment of atrial fibrillation is not well known. We performed an observational cohort study with long follow-up after the “cut-and-sew” Cox-maze III procedure (CM-III), including left atrial appendage excision. The aim was to analyze the incidence of stroke/transient ischemic attack (TIA) and the association to preoperative CHA2DS2-VASc (age in years, sex, congestive heart failure history, hypertension history, stroke/TIA, thromboembolism history, vascular disease history, diabetes mellitus) score. Methods Preoperative and perioperative data were collected in 526 CM-III patients operated in four centers 1994 to 2009, 412 men, mean age of 57.1 ± 8.3 years. The incidence of any stroke/TIA was identified through analyses of the Swedish National Patient and Cause-of-Death Registers and from review of individual patient records. The cumulative incidence of stroke/TIA and association with CHA2DS2-VASc score was estimated using methods accounting for the competing risk of death. Results Mean follow-up was 10.1 years. There were 29 patients with any stroke/TIA, including 6 with intracerebral bleedings (2 fatal) and 4 with perioperative strokes (0.76%). The remaining 13 ischemic strokes and six TIAs occurred at a mean of 7.1 ± 4.0 years postoperatively, with an incidence of 0.36% per year (19 events per 5,231 patient-years). In all CHA2DS2-VASc groups, observed ischemic stroke/TIA rate was lower than predicted. A higher risk of ischemic stroke/TIA was seen in patients with CHA2DS2-VASc score 2 or greater compared with score 0 or 1 (hazards ratio 2.15, 95% confidence interval: 0.87 to 5.32) but no difference by sex or stand-alone versus concomitant operation. No patient had ischemic stroke as cause of death. Conclusions This multicenter study showed a low incidence of perioperative and long-term postoperative ischemic stroke/TIA after CM-III. Although general risk of ischemic stroke/TIA was reduced, patients with CHA2DS2-VASc score 2 or greater had a higher risk compared with score 0 or 1. Complete left atrial appendage excision may be an important reason for the low ischemic stroke rate.
  •  
2.
  • Blomström-Lundqvist, Carina, et al. (författare)
  • Effect of Catheter Ablation vs Antiarrhythmic Medication on Quality of Life in Patients With Atrial Fibrillation : The CAPTAF Randomized Clinical Trial
  • 2019
  • Ingår i: JAMIA Journal of the American Medical Informatics Association. - Chicago : American Medical Association (AMA). - 1067-5027 .- 1527-974X .- 0098-7484 .- 1538-3598. ; 321:11, s. 1059-1068
  • Tidskriftsartikel (refereegranskat)abstract
    • IMPORTANCE Quality of life is not a standard primary outcome in ablation trials, even though symptoms drive the indication. OBJECTIVE To assess quality of life with catheter ablation vs antiarrhythmic medication at 12 months in patients with atrial fibrillation. DESIGN, SETTING, AND PARTICIPANTS Randomized clinical trial at 4 university hospitals in Sweden and 1 in Finland of 155 patients aged 30-70 years with more than 6 months of atrial fibrillation and treatment failure with 1 antiarrhythmic drug or beta-blocker, with 4-year follow-up. Study dateswere July 2008-September 2017. Major exclusionswere ejection fraction <35%, left atrial diameter > 60 mm, ventricular pacing dependency, and previous ablation. INTERVENTIONS Pulmonary vein isolation ablation (n= 79) or previously untested antiarrhythmic drugs (n= 76). MAIN OUTCOMES AND MEASURES Primary outcomewas the General Health subscale score (Medical Outcomes Study 36-Item Short-Form Health Survey) at baseline and 12 months, assessed unblinded (range, 0 [worst] to 100 [best]). There were 26 secondary outcomes, including atrial fibrillation burden (% of time) from baseline to 12 months, measured by implantable cardiac monitors. The first 3 months were excluded from rhythm analysis. RESULTS Among 155 randomized patients (mean age, 56.1 years; 22.6% women), 97% completed the trial. Of 79 patients randomized to receive ablation, 75 underwent ablation, including 2 who crossed over to medication and 14 who underwent repeated ablation procedures. Of 76 patients randomized to receive antiarrhythmic medication, 74 received it, including 8 who crossed over to ablation and 43 for whom the first drug used failed. General Health score increased from 61.8 to 73.9 points in the ablation group vs 62.7 to 65.4 points in the medication group (between-group difference, 8.9 points; 95% CI, 3.1-14.7; P=.003). Of 26 secondary end points, 5 were analyzed; 2 were null and 2 were statistically significant, including decrease in atrial fibrillation burden (from 24.9% to 5.5% in the ablation group vs 23.3% to 11.5% in the medication group; difference -6.8%[95% CI, -12.9% to -0.7%]; P=.03). Of the Health Survey subscales, 5 of 7 improved significantly. Most common adverse events were urosepsis (5.1%) in the ablation group and atrial tachycardia (3.9%) in the medication group. CONCLUSIONS AND RELEVANCE Among patients with symptomatic atrial fibrillation despite use of antiarrhythmic medication, the improvement in quality of life at 12 months was greater for those treated with catheter ablation compared with antiarrhythmic medication. Although the study was limited by absence of blinding, catheter ablation may offer an advantage for quality of life.
  •  
3.
  • Holmqvist, Fredrik, et al. (författare)
  • A decade of catheter ablation of cardiac arrhythmias in Sweden : ablation practices and outcomes
  • 2019
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 40:10, s. 820-830
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Catheter ablation is considered the treatment of choice for many tachyarrhythmias, but convincing 'real-world' data on efficacy and safety are lacking. Using Swedish national registry data, the ablation spectrum, procedural characteristics, as well as ablation efficacy and reported adverse events are reported.Methods and Results: Consecutive patients (≥18 years of age) undergoing catheter ablation in Sweden between 01 January 2006 and 31 December 2015 were included in the study. Follow-up (repeat ablation and vital status) was collected through 31 December 2016. A total of 26 642 patients (57 ± 15 years, 62% men), undergoing a total of 34 428 ablation procedures were included in the study. In total, 4034 accessory pathway/Wolff-Parkinson-White syndrome (12%), 7358 AV-nodal re-entrant tachycardia (21%), 1813 atrial tachycardia (5.2%), 5481 typical atrial flutter (16%), 11 916 atrial fibrillation (AF, 35%), 2415 AV-nodal (7.0%), 581 premature ventricular contraction (PVC, 1.7%), and 964 ventricular tachycardia (VT) ablations (2.8%) were performed. Median follow-up time was 4.7 years (interquartile range 2.7-7.0). The spectrum of treated arrhythmias changed over time, with a gradual increase in AF, VT, and PVC ablation (P < 0.001). Decreasing procedural times and utilization of fluoroscopy with time, were seen for all arrhythmia types. The rates of repeat ablation differed between ablation types, with the highest repeat ablation seen in AF (41% within 3 years). The rate of reported adverse events was low (n = 595, 1.7%). Death in the immediate period following ablation was rare (n = 116, 0.34%).Conclusion: Catheter ablations have shifted towards more complex procedures over the past decade. Fluoroscopy time has markedly decreased and the efficacy of catheter ablation seems to improve for AF.
  •  
4.
  • Holmqvist, Fredrik, et al. (författare)
  • Increasing Ablation Volumes And A Shift Towards More Complex Arrhythmias : Data From The Swedish National Catheter Ablation Registry
  • 2018
  • Konferensbidrag (refereegranskat)abstract
    • Background: Catheter ablation has become the treatment of choice for many tachyarrhythmias. The ablation techniques are continuously refined and the indications expanded, enabling treatment of more complex substrates. Hence, the spectrum of treated arrhythmias is likely to have changed over time, but compelling data on this are lacking.Objective: The present study set out to explore the changing pattern of ablations performed in the setting of a universal, single-payer healthcare system, using data from the Swedish national catheter ablation registry.Methods: The Swedish National Catheter Ablation Registry covers virtually all (>97%) catheter ablations performed in Sweden since 2005 and comprises 42,192 ablations on 32,237 individual patients. In the present analysis, all ablations performed between 2005 and 2016 were included.Results: In 2005, there were 7 ablation centers in Sweden performing a total of 1,584 ablations (226/center; 175/million). In 2016, 11 ablation centers performed 5,022 ablations (457/center; 502/million). Ablation of atrial fibrillation increased from 326 ablations (21% of all) in 2005 to 2,063 (41%) in 2016. Although, the number of ablation procedures for ventricular tachycardia and premature ventricular contractions is increasing, it is still on a relatively modest level (Figure). In contrast to other reports, there is no apparent decline in the number of accessory pathway ablations.Conclusion: In the setting of a universal, single-payer healthcare system, the number of ablations more than tripled over a 10-year period. Ablation of atrial fibrillation is the main driver behind this increase and accounted for 41% of all ablations in Sweden in 2016.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy