SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lagerstrand Kerstin M) srt2:(2020-2024)"

Sökning: WFRF:(Lagerstrand Kerstin M) > (2020-2024)

  • Resultat 1-25 av 47
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Belavy, D. L., et al. (författare)
  • Characterization of Intervertebral Disc Changes in Asymptomatic Individuals with Distinct Physical Activity Histories Using Three Different Quantitative MRI Techniques
  • 2020
  • Ingår i: Journal of Clinical Medicine. - : MDPI AG. - 2077-0383. ; 9:6
  • Tidskriftsartikel (refereegranskat)abstract
    • (1) Background: Assessments of intervertebral disc (IVD) changes, and IVD tissue adaptations due to physical activity, for example, remains challenging. Newer magnetic resonance imaging techniques can quantify detailed features of the IVD, where T2-mapping and T2-weighted (T2w) and Dixon imaging are potential candidates. Yet, their relative utility has not been examined. The performances of these techniques were investigated to characterize IVD differences in asymptomatic individuals with distinct physical activity histories. (2) Methods: In total, 101 participants (54 women) aged 25-35 years with distinct physical activity histories but without histories of spinal disease were included. T11/12 to L5/S1 IVDs were examined with sagittal T2-mapping, T2w and Dixon imaging. (3) Results: T2-mapping differentiated Pfirrmann grade-1 from all other grades (p< 0.001). Most importantly, T2-mapping was able to characterize IVD differences in individuals with different training histories (p< 0.005). Dixon displayed weak correlations with the Pfirrmann scale, but presented significantly higher water content in the IVDs of the long-distance runners (p< 0.005). (4) Conclusions: Findings suggested that T2-mapping best reflects IVD differences in asymptomatic individuals with distinct physical activity histories changes. Dixon characterized new aspects of IVD, probably associated with IVD hypertrophy. This complementary information may help us to better understand the biological function of the disc.
  •  
2.
  • Cetinic, I., et al. (författare)
  • Ultrasound Shear Wave Elastography, Shear Wave Dispersion and Attenuation Imaging of Pediatric Liver Disease with Histological Correlation
  • 2022
  • Ingår i: Children. - : MDPI AG. - 2227-9067. ; 9:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: To evaluate the feasibility of multiple ultrasound markers for the non-invasive characterization of fibrosis, inflammation and steatosis in the liver in pediatric patients. Materials and methods: The quantitative ultrasound measures shear wave elastography (SWE), shear wave dispersion (SWD) and attenuation imaging (ATI) were compared and correlated with percutaneous liver biopsies and corresponding measures in a control cohort. Results: The median age of the 32 patients was 12.1 years (range 0.1-17.9), and that of the 15 controls was 11.8 years (range: 2.6-16.6). Results: There was a significant difference in SWE values between histologic grades of fibrosis (p = 0.003), with a positive correlation according to the grade (r = 0.7; p < 0.0001). Overall, a difference in SWD values between grades of inflammation was found (p = 0.009) but with a lack of correlation (r = 0.1; p = 0.67). Comparing inflammation grades 0-1 (median:13.6 m/s kHz [min; max; 8.4; 17.5]) versus grades 2-3 (16.3 m/s kHz [14.6; 24.2]) showed significant differences between the groups (p = 0.003). In the 30 individuals with a steatosis score of 0, ATI was measured in 23 cases with a median value of 0.56 dB/cm/MHz. Conclusion: Comprehensive ultrasound analysis was feasible to apply in children and has the potential to reflect the various components of liver affection non-invasively. Larger studies are necessary to conclude to what extent these image-based markers can classify the grade of fibrosis, inflammation and steatosis.
  •  
3.
  • Hebelka, Hanna, 1977, et al. (författare)
  • Lumbar vertebral T2-relaxation time investigated with T2-mapping at multiple time points in a day demonstrate large individual variations
  • 2022
  • Ingår i: Diagnostic and Interventional Radiology. - : Galenos Yayinevi. - 1305-3825. ; 28:1, s. 92-97
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE The increasing interest of endplate and Modic changes as potential pain generators in low back pain (LBP), along with advancement of functional quantitative magnetic resonance imaging (MRI) techniques, makes it important to characterize the vertebral dynamic behavior in detail. This study aims to perform characterization of the dynamic behavior of the vertebral bodies (VB) by investigating the VB diurnal variation in T2-relaxation time in a cross-sectional asymptomatic group of individuals. METHODS T2-mapping of 30 VBs (L1-L5) in six healthy volunteers (mean age, 40 years; range, 29-65 years) was performed with a 1.5 Tesla MRI at three time points over the day (7 am, 12 am, 5 pm). Volumetric regions of interest were segmented manually to determine VB T2-relaxation time, which was compared between the three time points. RESULTS On a group level only small and not significant diurnal VB variation was detected (all P >.10), with median T2 (ms) (quartiles; Q1, Q3) at the three time points 88.7 (84.1, 99.1), 87.3 (85.0, 96.1) and 87.8 (84.4, 99.2). However, in some VBs up to 7% increase respectively 9% decrease in T2-relaxation time was found during the day. Further, there was a relatively large variation between the individuals in absolute VB T2-relaxation times (range 73.2-108.3 ms), but small differences between the VBs within an individual. CONCLUSION This first T2-mapping study of the VB signal dynamics, in repeated investigations during one day, display variation in T2-relaxation time in specific individual VBs but were negligible on a group level. The result may be of importance when evaluating patients with spinal pathologies and suggest further examinations of dynamic changes not only of the disc but also vertebrae. © Turkish Society of Radiology 2021.
  •  
4.
  • Rasmussen, A. M., et al. (författare)
  • Repeatability of diffusion-based stiffness prediction – A healthy volunteer study
  • 2024
  • Ingår i: Radiography. - 1078-8174 .- 1532-2831. ; 30:2, s. 524-530
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: The study investigated the repeatability of brain diffusion-based stiffness prediction (DWIstiff) in healthy volunteers. Methods: Thirty-one healthy volunteers were examined with DWIstiff using two different sets of b-values: b200-1500 s/mm2 (DWIstiff, 1500) and b200-1000 s/mm2 (DWIstiff, 1000). Each b-value set was scanned twice per imaging session without repositioning the participants. DWIstiff images were reconstructed from each set. Two observers delineated regions of interest (ROIs) on each DWIstiff image. The repeatability coefficient (RC), coefficient of variation (CV), inter- and intraobserver agreement were calculated. Results: After excluding three participants due to image artifacts, the study included twenty-eight volunteers (mean age (range)) 37 years (24–62), 10 males, 18 females). For DWIstiff, 1500, the lowest and the highest RCs were in the parietal lobe (0.52) and respectively the brain stem (1.17). The lowest RC for DWIstiff, 1000 was in the frontal lobe (0.42) and the highest in the brain stem (1.58). The CV for whole brain measurements was 3.83 % for DWIstiff, 1500 and 4.93 % for DWIstiff, 1000. The Bland‒Altman (BA) limits of agreement (LoA) for the intraobserver agreement of DWIstiff, 1500 were −0.90 to 1.06 and respectively −0.78 to 0.88 for DWIstiff, 1000. Regarding interobserver agreement, the LoA were −0.85 to 0.94 for DWIstiff, 1500 and −0.61 to 0.66 for DWIstiff, 1000. Conclusion: DWIstiff is a precise technique with some observer dependence. Repeatability is higher for DWIstiff, 1000 s/mm2 than for DWIstiff 1500 s/mm2. Implications for practice: Our findings suggest that DWIstiff can reliably detect stiffness changes larger than 4.93 % in healthy volunteers. Further studies should investigate whether the repeatability of DWIstiff may be affected by the presence of pathology such as a brain tumor.
  •  
5.
  • Agerskov, Simon, et al. (författare)
  • MRI diffusion and perfusion alterations in the mesencephalon and pons as markers of disease and symptom reversibility in idiopathic normal pressure hydrocephalus
  • 2020
  • Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 15:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction Core symptomatology in idiopathic normal pressure hydrocephalus (iNPH) points at dysfunction in the mesencephalon and pons indicating pathological changes in these regions, but only a few studies have addressed the issue. The aim of this study was to investigate diffusion (ADC) and perfusion patterns pre- and postoperatively in these areas in iNPH. Methods Twenty iNPH patients and 15 healthy controls were included. Patients underwent a clinical examination and brain MRI pre- and 3-6 months postoperatively. The MRI-scan included diffusion and dynamic susceptibility contrast perfusion weighted sequences. Regions of interest in the mesencephalon and pons were drawn on a FLAIR sequence and co-registered to ADC maps and perfusion data. Results There were no significant differences in pre or postoperative ADC compared to the control group, however postoperative ADC increased by 10% (p = 0.026) in the mesencephalon and 6% (p = 0.016) in the pons in all patients and also in the subgroup of shunt responders by 11% (p = 0.021) and 4% (p = 0.020), respectively. Preoperative relative cerebral blood flow (rCBF) was similar in iNPH patients and controls. Postoperatively, rCBF increased in shunt responders by 6% (p = 0.02) in the mesencephalon and 11% (p = 0.004) in the pons. This increase correlated with the degree of clinical improvement (r(s)= 0.80, p = 0.031 and r(s)= 0.66, p = 0.021, respectively). Conclusion The postoperative increase in ADC and the correlation between postoperative increase in rCBF and clinical improvement in the mesencephalon and pons shown in this study point at an involvement of these areas in the core pathophysiology and its reversibility in iNPH.
  •  
6.
  • Arvidsson, Jonathan, et al. (författare)
  • Arterial occlusion duration affects the cuff-induced hyperemic response in skeletal muscle BOLD perfusion imaging as shown in young healthy subjects
  • 2023
  • Ingår i: Magnetic Resonance Materials in Physics Biology and Medicine. - 1352-8661. ; 36:6, s. 897-910
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective Dynamic BOLD MRI with cuff compression, inducing ischemia and post-occlusive hyperemia in skeletal mus-cle, has been pointed out as a potential diagnostic tool to assess peripheral limb perfusion. The objective was to explore the robustness of this technique and its sensitivity to the occlusion duration. Materials and methods BOLD images were acquired at 3 T in 14 healthy volunteers. T*2-imaging with 5-and 1.5-min occlu-sions were acquired and several semi-quantitative BOLD parameters were derived from ROI-based T*2-time curves. Differ-ences in parameters from the two different occlusion durations were evaluated in the gastrocnemius and soleus muscles using non-parametrical tests. Intra-and inter-scan repeatability were evaluated with coefficient of variation.Results Longer occlusion duration resulted in an increased hyperemic signal effect yielding significantly different values (p < 0.05) in gastrocnemius for all parameters describing the hyperemic response, and in soleus for two of these parameters. Specifically, 5-min occlusion yielded steeper hyperemic upslope in gastrocnemius (41.0%; p < 0.05) and soleus (59.7%; p = 0.03), shorter time to half peak in gastrocnemius (46.9%; p = 0.00008) and soleus (33.5%; p = 0.0003), and shorter time to peak in gastrocnemius (13.5%; p = 0.02). Coefficients of variation were lower than percentage differences that were found significant. Discussion Findings show that the occlusion duration indeed influences the hyperemic response and thus should play a part in future methodological developments.
  •  
7.
  • Arvidsson, Jonathan, et al. (författare)
  • Effects of bolus injection duration on perfusion estimates in dynamic CT and dynamic susceptibility contrast MRI
  • 2023
  • Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - : Springer Science and Business Media LLC. - 0968-5243 .- 1352-8661. ; 36:1, s. 95-106
  • Tidskriftsartikel (refereegranskat)abstract
    • Estimates of cerebral blood flow (CBF) and tissue mean transit time (MTT) have been shown to differ between dynamic CT perfusion (CTP) and dynamic susceptibility contrast MRI (DSC-MRI). This study investigates whether these discrepancies regarding CBF and MTT between CTP and DSC-MRI can be attributed to the different injection durations of these techniques. Five subjects were scanned using CTP and DSC-MRI. Region-wise estimates of CBF, MTT, and cerebral blood volume (CBV) were derived based on oscillatory index regularized singular value decomposition. A parametric model that reproduced the shape of measured time curves and characteristics of resulting perfusion parameter estimates was developed and used to simulate data with injection durations typical for CTP and DSC-MRI for a clinically relevant set of perfusion scenarios and noise levels. In simulations, estimates of CBF/MTT showed larger negative/positive bias and increasing variability for CTP when compared to DSC-MRI, especially for high CBF levels. While noise also affected estimates, at clinically relevant levels, the injection duration effect was larger. There are several methodological differences between CTP and DSC-MRI. The results of this study suggest that the injection duration is among those that can explain differences in estimates of CBF and MTT between these bolus tracking techniques.
  •  
8.
  • Cetinic, Ivan, et al. (författare)
  • Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow-up of pediatric liver grafts
  • 2023
  • Ingår i: Pediatric Transplantation. - 1397-3142. ; 27:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: It is unknown how shear wave dispersion (SWD) is displayed in pediatric liver transplant recipients and not fully elucidated how ultrasound shear wave elastography (2D-SWE) display within this cohort, which is important to determine to improve noninvasive surveillance of these patients. The study aimed to compare SWE and SWD values with histopathology in pediatric liver recipients.Methods: Forty-eight pediatric liver recipients were examined with SWE in conjunction with an elective liver biopsy (clinically without complication). Additionally, SWD values were measured in 21 children. SWE and SWD values were compared to histologically determined fibrosis graded as none-to-mild (F0-1) and moderate-to-severe (F2-4), and inflammation graded as low (grade 0-1) and high (grade 2-4).Results: Two children were excluded due to SWE IQR/median > 30% kPa. The mean age across 46 included patients was 10.9 years (range 1.4-18). The number of patients and median (range) SWE value (kPa) for each stage of fibrosis were: F0-1 [n = 23; 5.8 (3.2-16.1)], F2 [n = 22; 6.0 (4.5-25.9)], F3 [n = 1; 33.3], and F4 [n = 0]. Significantly higher SWE values and greater variability were registered in F2-4 vs. F0-1 (p = .05). Grade of fibrosis correlated weakly to SWE values (r = .3; p = .05), but not to SWD values (r = .2; p = .27). In patients with low-grade inflammation, median SWD was 13.7 m/s KHz (10.7-17.6). Only one patient had high-grade inflammation.Conclusions: Uncomplicated transplanted liver grafts in a small pediatric cohort revealed slightly increased SWE and SWD values compared to previously reported values in healthy children. This likely reflect both the fibrotic and inflammatory elements in the grafts; however, other confounders impacting the liver's viscoelastic properties are also probable factors.
  •  
9.
  • Eriksson, Stefanie, et al. (författare)
  • Texture Analysis of Magnetic Resonance Images Enables Phenotyping of Potentially Painful Annular Fissures.
  • 2022
  • Ingår i: Spine. - 1528-1159. ; 47:5, s. 430-437
  • Tidskriftsartikel (refereegranskat)abstract
    • Retrospective analysis of prospectively collected data.To investigate whether intervertebral disc (IVD) image features, extracted from magnetic resonance (MR) images, can depict the extension and width of annular fissures and associate them to pain.Annular fissures are suggested to be associated with low back pain (LBP). Magnetic resonance imaging (MRI) is a sensitive method, yet fissures are sometimes unobservable in T2-weighted MR-images, even though fissure information is present in the image. Image features can mathematically be calculated from MR-images and might reveal fissure characteristics.44 LBP patients who underwent MRI, low-pressure discography (<50psi) and computed tomography (CT) sequentially in one day, were reviewed. After semi-automated segmentation of 126 discs, image features were extracted from the T2-weighted images. The number of image features were reduced with principle component analysis (PCA). CT-discograms were graded and dichotomized regarding extension and width of fissures. IVDs were divided into fissures extending to outer annulus vs. short/no fissures. Fissure width was dichotomized into narrow (<10%) vs. broad fissures (>10%), and into moderately broad (10%-50%) vs. very broad fissures (>50%). Logistic regression was performed to investigate if image features could depict fissure extension to outer annulus and fissure width. As a sub-analysis, the association between image features used to depict fissure characteristics and discography-provoked pain-response were investigated.Fissure extension could be depicted with sensitivity/specificity=0.97/0.77 and area under curve (AUC)=0.97. Corresponding results for width depiction were sensitivity/specificity=0.94/0.39 and 0.85/0.62, and AUC=0.86 and 0.81 for narrow vs. broad and moderately broad vs. very broad fissures respectively. Pain prediction with image features used for depicting fissure characteristics showed sensitivity/specificity=0.90/0.36, 0.88/0.4, 0.93/0.33; AUC=0.69, 0.75 and 0.73 respectively.Standard MR-images contains fissure information associated to pain that can be depicted with image features, enabling non-invasive phenotyping of potentially painful annular fissures.Level of Evidence: 2.
  •  
10.
  • Flehr, Alison, et al. (författare)
  • Development of a novel method to measure bone marrow fat fraction in older women using high-resolution peripheral quantitative computed tomography
  • 2022
  • Ingår i: Osteoporosis International. - : Springer Science and Business Media LLC. - 0937-941X .- 1433-2965. ; 33:7, s. 1545-1556
  • Tidskriftsartikel (refereegranskat)abstract
    • Bone marrow adipose tissue (BMAT) has been implicated in a number of conditions associated with bone deterioration and osteoporosis. Several studies have found an inverse relationship between BMAT and bone mineral density (BMD), and higher levels of BMAT in those with prevalent fracture. Magnetic resonance imaging (MRI) is the gold standard for measuring BMAT, but its use is limited by high costs and low availability. We hypothesized that BMAT could also be accurately quantified using high-resolution peripheral quantitative computed tomography (HR-pQCT). Methods: In the present study, a novel method to quantify the tibia bone marrow fat fraction, defined by MRI, using HR-pQCT was developed. In total, 38 postmenopausal women (mean [standard deviation] age 75.9 [3.1] years) were included and measured at the same site at the distal (n = 38) and ultradistal (n = 18) tibia using both MRI and HR-pQCT. To adjust for partial volume effects, the HR-pQCT images underwent 0 to 10 layers of voxel peeling to remove voxels adjacent to the bone. Linear regression equations were then tested for different degrees of voxel peeling, using the MRI-derived fat fractions as the dependent variable and the HR-pQCT-derived radiodensity as the independent variables. Results: The most optimal HR-pQCT derived model, which applied a minimum of 4 layers of peeled voxel and with more than 1% remaining marrow volume, was able to explain 76% of the variation in the ultradistal tibia bone marrow fat fraction, measured with MRI (p < 0.001). Conclusion: The novel HR-pQCT method, developed to estimate BMAT, was able to explain a substantial part of the variation in the bone marrow fat fraction and can be used in future studies investigating the role of BMAT in osteoporosis and fracture prediction.
  •  
11.
  • Gao, Sinsia, 1966, et al. (författare)
  • The usefulness of left ventricular volume and aortic diastolic flow reversal for grading chronic aortic regurgitation severity-Using cardiovascular magnetic resonance as reference
  • 2021
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273. ; 340, s. 59-65
  • Tidskriftsartikel (refereegranskat)abstract
    • Echocardiographic evaluation of chronic aortic regurgitation (AR) severity can lead to diagnostic ambiguity due to few feasible parameters or incongruent findings. The aim of the present study was to improve the diagnostic usefulness of left ventricular (LV) enlargement and aortic end-diastolic flow velocity (EDFV) using cardiovascular magnetic resonance (CMR) as reference. Patients (n = 120) were recruited either prospectively (n = 45) or retrospectively (n = 75). Severe AR (CMR regurgitant fraction 75/87 ml/m2) were identified using ROC analyses in the derivation group. The corresponding thresholds for EDFV were 10 cm/s. In the test group, the positive/negative likelihood ratios to rule in/rule out severe AR using EDVI were 10.0/0.14 (traditional), 6.2/0.11 (recommended), and using EDFV were 10.2/0.08. To rule in and rule out severe AR using derived cut-off values instead of 2 SD reduced the false positives by 92%, whereas using EDFV <10 cm/s instead of <20 cm/s reduced the false negatives by 94%. In conclusion, EDVI and EDFV as quantitative parameters are useful to rule in or rule out severe chronic AR. Importantly, other causes of LV enlargement have to be considered.
  •  
12.
  • Hebelka, Hanna, 1977, et al. (författare)
  • Axial Loading during MRI Induces Lumbar Foraminal Area Changes and Has the Potential to Improve Diagnostics of Nerve Root Compromise
  • 2022
  • Ingår i: Journal of Clinical Medicine. - : MDPI AG. - 2077-0383. ; 11:8
  • Tidskriftsartikel (refereegranskat)abstract
    • Lumbar foraminal stenosis is a common cause of lumbar radiculopathy and conventionally assessed with magnetic resonance imaging (MRI) in supine-positioned patients. An MRI acquired during spine loading may unmask pathology not otherwise revealed in a relaxed position. Therefore, we investigated how spine loading during MRI affects lumbar foramina. In 89 low-back pain patients’ lumbar, MRIs were performed in a relaxed supine position and during axial loading using a Dynawell® compression device. The smallest area of all intervertebral foramina at levels L3/L4–L5/S1 (534 foramina) was determined using a freehand polygonal tool in parasagittal T2-weighted sequences. The grading system described by Lee et al. was also used to qualitatively assess foraminal stenosis. Overall, a mean reduction of 2.2% (mean −0.89 cm2 and −0.87 cm2, respectively) was observed (p = 0.002), however for individual foramina large variations, with up to about 50% increase or decrease, were seen. Stratified for lumbar level, an area reduction was found for L3/L4 and L4/L5 foramina (mean change −0.03 cm2; p = 0.036; and −0.03 cm2; p = 0.004, respectively) but not for L5/S1. When comparing the measured area changes to qualitative foraminal grading, 22% of the foramina with a measured area decrease were evaluated with a higher grading. Thus, detailed information on foraminal appearance and nerve root affection can be obtained using this method.
  •  
13.
  • Hebelka, Hanna, 1977, et al. (författare)
  • Clinical outcome and MRI appearance in a group of chronic low back pain patients more than 10 years after discography evaluation and consideration for surgery
  • 2023
  • Ingår i: BMC Musculoskeletal Disorders. - : Springer Science and Business Media LLC. - 1471-2474. ; 24:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundIt is an ongoing debate whether fusion surgery is superior to non-operative treatment for non-specific low back pain (LBP) in terms of patient outcome. Further, the evidence for how signs of intervertebral disc (IVD) degeneration on magnetic resonance imaging (MRI) correlate with patient outcome is insufficient. Longitudinal studies of low back pain (LBP) patients are thus of interest for increased knowledge. The aim of this study was to investigate long-term MRI appearance in LBP patients 11-14 years after discography.MethodsIn 2021, 30 LBP patients who had same-day discography and MRI in 2007-2010 were asked to undergo MRI (Th12/L1-L5/S1), complete visual analog scale (VAS), Oswestry Disability Index (ODI) and EuroQol-5 Dimension (EQ5D) questionnaires. Patients who had fusion surgery before the follow-up were compared with those without such surgery. MRIs were evaluated on Pfirrmann grade, endplate classification score (EPS), and High Intensity Zones (HIZ). For each disk it was noted if injected at baseline or not.ResultsOf 17 participants (6 male;mean age 58.5 years, range 49-72), 10 (27 disks) had undergone fusion surgery before the follow-up. No differences in VAS, ODI, or EQ5D scores were found between patients with and without surgery (mean 51/32/0.54 vs. 50/37/0.40, respectively; 0.77 > p < 0.65). Other than more segments with EPS >= 4 in the surgery group (p < 0.05), no between-group differences were found in longitudinal change in MRI parameters. Of 75 non-fused disks, 30 were injected at baseline. Differences were found between injected and non-injected disks at both baseline and follow-up for Pfirrmann grade and HIZ, and at follow-up for EPS (0.04 > p < 0.001), but none for progression over time (0.09 > p < 0.82).ConclusionsOther than more endplate changes in the surgery group, no differences in longitudinal change of MRI parameters were established between LBP patients treated with or without fusion surgery in the studied cohort. The study also highlights the limited progress of degenerative changes, which may be seen over a decade, despite needle puncture and chronic LBP.
  •  
14.
  • Hebelka, Hanna, 1977, et al. (författare)
  • Coexistence of Vertebral and Intervertebral Disc Changes in Low Back Pain Patients—In Depth Characterization with Same Day MRI and CT Discography
  • 2023
  • Ingår i: Diagnostics. - 2075-4418. ; 13:23
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to investigate to what extent annular fissures, vertebral and endplate changes, and Modic changes (MCs), coexist in low back pain (LBP) patients by using multiple imaging modalities. Sixty-two LBP patients (mean age 45 years, range 24–63, 53% men) were examined with same-day CT-discography and MRI. Intervertebral discs punctured for discography (n = 204) were evaluated on MRI [Pfirrmann grade, High-Intensity Zone (HIZ)] and on CT-discograms [Modified Dallas Discogram Score (DDS)]. DDS≥ 1, i.e., disc fissures involving the outer annulus were further digitomized into delimitable fissuring (<50% of annulus affected) or non-delimitable annular fissuring. Using both MRI and CT, adjacent vertebrae and endplates were assessed for MC, vertebral sclerosis, and a modified endplate defect score (EPS). In 194 discs the contrast agent was adequately injected during discography, of which 160 (83%) displayed outer annular fissures, with 91 (47%) of the latter being delimitable fissures. Most discs with delimitable fissures were moderately degenerated; 68% Pfirrmann grade ≤3, 71% EPS ≤ 2, and 12% displayed MC. The majority (76%) of MCs were associated with advanced adjacent disc degeneration; 84% Pfirrmann grade ≥4, 76% with non-delimitable annular fissuring, 59% EPS≥ 4, and 34% EPS of 3. A total 95 HIZ (47%) were found, of which 54 had delimitable fissuring, while the remainder displayed non-delimitable fissuring. Vertebral sclerosis was commonly observed (26%), both with MCs (73%) and without MCs (27%), and not specifically linked to MC type 3. A total of 97% of segments with vertebral sclerosis displayed outer annular fissures. These findings were significant (0.046 > p > 0.0001), except between HIZ and adjacent sclerosis (p = 0.303). To conclude, the present study confirmed a close interplay between the disc and adjacent vertebra and endplates. The fact that a majority of discs with delimitable annular fissures did not coexist with pronounced endplate changes and/or MCs, however, supports the theory that disc fissuring is an early event in the degenerative cascade. This was further supported by the fact that MCs were strongly linked to extensive disc fissuring and to advanced endplate damage. Further, vertebral sclerosis was common also in vertebra without MCs and strongly associated to annular fissuring, indicating that sclerosis is a previously underestimated feature of a general degenerative process.
  •  
15.
  • Hebelka, Hanna, 1977, et al. (författare)
  • Loading of the Spine in Low Back Pain Patients Does Not Induce MRI Changes in Modic Lesions: A Prospective Clinical Study
  • 2022
  • Ingår i: Diagnostics (Basel). - : MDPI AG. - 2075-4418. ; 12:8
  • Tidskriftsartikel (refereegranskat)abstract
    • Modic changes (MCs) are gaining increased interest as potential generators of low back pain (LBP). The current aim was to investigate possible spinal loading effects on the MRI signal in MCs in patients with LBP. Supine lumbar MRIs were performed and immediately repeated with axial loading in 100 LBP patients. A total of 43 patients (23 male, mean age 45.7 years) had MCs. Each Modic was outlined on all sagittal T2-weighted images (>25% affected vertebrae). For reference, regions of interest were placed in both vertebrae without Modic and in Modic-free tissue in vertebrae with Modic. The Modic signal intensity, normalized to cerebrospinal fluid, and Modic volume were compared between MRIs with and without spinal loading. Of the 94 MCs, 36.2% (n = 34) were type I, 58.5% (n = 55) were type II, and 5.3% (n = 5) were type III. No differences in Modic volume (mean 0.046 cm3; p = 0.25) between the MRIs with and without spinal loading were found. In addition, no significant changes in Modic signal were induced by loading (mean 1.5% difference; p = 0.308). Loading increased the signal in the reference regions of interest in vertebrae both with Modic (mean 5.5%; p = 0.002) and without (mean 3.5%; SD 0.09; p = 0.02). To conclude, MRIs performed with and without spinal loading showed no change in either volume or signal of MCs, suggesting that most MCs are not instantaneously influenced by biomechanical load.
  •  
16.
  •  
17.
  • Hedelin, Henrik, 1975, et al. (författare)
  • Postoperative stability following a triple pelvic osteotomy is affected by implant configuration: a finite element analysis
  • 2022
  • Ingår i: Journal of Orthopaedic Surgery and Research. - : Springer Science and Business Media LLC. - 1749-799X. ; 17:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The triple pelvic osteotomy is an established surgical method with multiple modifications regarding surgical technique and choice of implant. The stability of the osteotomy is affected by numerous factors, and among these, the three-dimensional implant configuration is a scientifically less explored aspect. Methods We used a finite element model of a hemi-pelvis with a standardized triple osteotomy to calculate relative flexibility for loads in all translational degrees of freedom for five different implant configurations. Two of the configurations used entry points only feasible when implant removal was not necessary. Results The stability of the osteotomy improved with an increased distance between the implants in the plane of the osteotomy as well as for a more perpendicular angle relative to the osteotomy plane. The implant configurations with more entry points available made this easier to adhere to. Conclusion The use of bioabsorbable implants may provide better opportunities for optimal implant constructs which can, to a certain degree, compensate for the lesser mechanical stiffness of bioabsorbable polymers as compared to metal implants.
  •  
18.
  • Hedelin, Henrik, 1975, et al. (författare)
  • Stability in Pelvic Triple Osteotomies in Children Using Resorbable PLGA Screws for Fixation
  • 2021
  • Ingår i: Journal of Pediatric Orthopaedics. - : Ovid Technologies (Wolters Kluwer Health). - 0271-6798. ; 41:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The triple pelvic osteotomy (TPO) is a major redirectional osteotomy used to improve the acetabular coverage of the femoral head in selected pediatric patients with hip disorders. Traditionally the iliac osteotomy is stabilized by metal screws that require a second surgery for removal. Despite favorable results for both adults and children in related pelvic osteotomies, resorbable implants have not previously been used for TPOs. This study aims to suggest a novel modified TPO surgical method in children using resorbable poly lactic-co-glycolic acid (PLGA) screws for fixation and to radiographically evaluate the postoperative stability achieved by these implants in a case series. Methods: All patients (n=11) with dysplasia of the hip (2), Perthe disease (5), or Down syndrome (4), who underwent primary TPO surgery during 2013 to 2019, using resorbable PLGA screws for fixation were included. The stability of the osteotomy was evaluated in the postoperative radiograph series using the acetabular index, migration percentage, Sharp's angle and the center-edge angle. The osteotomy angle was introduced as a parameter to confirm the postoperative integrity of the achieved correction. All cases were evaluated until radiographic healing of the iliac osteotomy. Hospital notes were analyzed for complications or local reactions in relation to the implants. Results: In all studied hips, the overall achieved correction was well maintained. The mean (SD) correction achieved, from the preoperative images to the last measurable postoperative image, was a 16.7 degrees decrease for Sharp angle, a 20.9 degrees decrease in acetabular index and a 24.7 degrees increase for the center-edge angle, respectively. There were no complications related to the bioabsorption of the implants. Conclusion: The present findings suggest that the modified TPO method, using resorbable PLGA screws, provides sufficient stability and appears to be a promising alternative to traditional TPO. Avoiding implant removal is a major benefit in a pediatric population. Resorbable screws enable the surgeon to place implants with more degrees of freedom since later implant removal is not a limiting factor.
  •  
19.
  • Hutchins, John, et al. (författare)
  • A systematic review of validated classification systems for cervical and lumbar spinal foraminal stenosis based on magnetic resonance imaging.
  • 2022
  • Ingår i: European spine journal. - : Springer Science and Business Media LLC. - 1432-0932 .- 0940-6719. ; 31:6, s. 1358-1369
  • Tidskriftsartikel (refereegranskat)abstract
    • Foraminal stenosis is commonly investigated with radiological methods in patients with radiating pain in extremities. However, there is a lack of consensus regarding the methodology to assess compression of the nerve roots. This systematic review was performed to identify validated classification systems for foraminal stenosis in the lumbar and cervical spine based on magnetic resonance imaging (MRI).A systematic search was conducted according to the PRISMA guidelines. The search included Cochrane, Embase, Medline and PubMed databases going back 30years and up to September 2021. Three categories of words were used in different variations; foraminal stenosis, MRI and scoring. For inclusion, at least one word from each category had to be present. Articles suggesting classification systems or reporting on their validation were selected for inclusion.A total of 823 articles were identified and all abstracts were reviewed. Subsequently, a full-text review of 64 articles was performed and finally 14 articles were included. A total of three validated classification systems were found for the cervical and lumbar spine. The remaining 11 articles reported on validation or suggested modifications of the classification systems.The three classification systems demonstrated moderate to good reliability and have all been shown feasible in the clinical setting. There is however a need for further studies testing the validity of these classifications in relation to both clinical findings and to surgical outcome data.
  •  
20.
  • Hutchins, John, et al. (författare)
  • Cervical Foraminal Changes in Patients with Intermittent Arm Radiculopathy Studied with a New MRI-Compatible Compression Device
  • 2023
  • Ingår i: Journal of Clinical Medicine. - 2077-0383. ; 12:20
  • Tidskriftsartikel (refereegranskat)abstract
    • Diagnosing cervical foraminal stenosis with intermittent arm radiculopathy is challenging due to discrepancies between MRI findings and symptoms. This can be attributed to the fact that MRI images are often obtained in a relaxed supine position. This study aims to evaluate the feasibility of the Dynamic MRI Compression System (DMRICS) and to assess possible changes in cervical foramina, with both quantitative measurements and qualitative grading systems, with MRI during a simulated Spurling test. Ten patients (five women and five men, ages 29-45) with previously confirmed cervical foraminal stenosis underwent MRI scans using DMRICS. MRI images were acquired in both relaxed and provoked states. A radiologist assessed 30 foramina (C4-C7) on the symptomatic side in both patient positions. Quantitative and qualitative measures were performed, including the numeric rating scale (NRS) and the Park and Kim grading systems. The provoked state induced concordant neck and arm pain in 9 of 10 patients. Significant shifts in Park and Kim foraminal gradings were noted: 13 of 27 Park gradings and 9 of 27 Kim gradings escalated post provocation. No quantitative changes were observed. This pilot study indicates that the DMRICS device has the potential to improve diagnostic accuracy for cervical radiculopathy, demonstrating induced cervical foraminal changes during a simulated Spurling test while performing MRI.
  •  
21.
  • Hutchins, John, et al. (författare)
  • MRI evaluation of foraminal changes in the cervical spine with assistance of a novel compression device
  • 2023
  • Ingår i: Scientific Reports. - 2045-2322. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Standard supine Magnetic Resonance Imaging (MRI) does not acquire images in a position where most patients with intermittent arm radiculopathy have symptoms. The aim of this study was to test the feasibility of a new compression device and to evaluate image quality and foraminal properties during a Spurling test under MRI acquisition. Ten asymptomatic individuals were included in the study (6 men and 4 women; age range 27 to 55 years). First, the subjects were positioned in the cervical compression device in a 3 T MRI scanner, and a volume T2 weighted (T2w) sequence was acquired in a relaxed supine position (3 min). Thereafter, the position and compressive forces on the patient's neck (provocation position) were changed by maneuvering the device from the control room, with the aim to simulate a Spurling test, causing a mild foraminal compression, followed by a repeated image acquisition (3 min). A radiologist measured the blinded investigations evaluating cervical lordosis (C3-C7), foraminal area on oblique sagittal images and foraminal cross-distance in the axial plane. A total of three levels (C4-C7) were measured on the right side on each individual. Measurements were compared between the compressed and relaxed state. Reliability tests for inter- and intraclass correlation were performed. The device was feasible to use and well tolerated by all investigated individuals. Images of adequate quality was obtained in all patients. A significant increase (mean 9.4, p = 0.013) in the cervical lordosis and a decreased foraminal cross-distance (mean 32%, p < 0.001) was found, during the simulated Spurling test. The area change on oblique sagittal images did not reach a statistically significant change. The reliability tests on the quantitative measures demonstrated excellent intraobserver reliability and moderate to good interobserver reliability. Applying an individualized provocation test on the cervical spine, which simulates a Spurling test, during MRI acquisition was feasible with the novel device and provided images of satisfactory quality. MRI images acquired with and without compression showed changes in cervical lordosis and foraminal cross distance indicating the possibility of detecting changes of the foraminal properties. As a next step, the method is to be tested on symptomatic patients.
  •  
22.
  • Identeg, Fredrik, 1990, et al. (författare)
  • Low occurrence of MRI spinal changes in elite climbing athletes; a cross-sectional study.
  • 2023
  • Ingår i: BMC sports science, medicine & rehabilitation. - : Springer Science and Business Media LLC. - 2052-1847. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • To examine the occurrence of magnetic resonance imaging (MRI) changes in the thoracolumbar spine among elite climbing athletes.All climbers of the Swedish national sport climbing team (n=8), and individuals having trained for selection to the national team (n=11), were prospectively included. A control group, matched in age and sex, were recruited. All participants underwent a thoracolumbar MRI (1.5T, T1- and T2-weighted imaging), evaluated according to Pfirrmann classification, modified Endplate defect score, Modic changes, apophyseal injuries and spondylolisthesis. Pfirrmann≥3, Endplate defect score≥2 and Modic≥1 was defined as degenerative findings.Fifteen individuals, 8 women, participated in both the climbing group (mean age 23.1, SD 3.2years) and the control group respectively (mean age 24.3, SD 1.5years). In the climbing group, 6.1% of the thoracic and 10.6% of the lumbar intervertebral discs showed signs of degeneration according to Pfirrmann. One disc with a grade above 3 was present. Modic changes in the thoracic/lumbar spine were prevalent in 1.7%/1.3% of the vertebrae. Degenerative endplate changes according to the Endplate defect score were found in 8.9% and 6.6% of the thoracic and lumbar spinal segments of the climbing group, respectively. Two apophyseal injuries were found, while no participants displayed signs of spondylolisthesis. There was no difference in point-prevalence of radiographic spinal changes between climbers and controls (0.07
  •  
23.
  • Johansson, Frida, et al. (författare)
  • Non-Invasive Evaluation of Intradiscal Deformation during Axial Loading of the Spine Using Deformation-Field Magnetic Resonance Imaging: A Potential Tool for Micro-Instability Measurements
  • 2022
  • Ingår i: Journal of Clinical Medicine. - : MDPI AG. - 2077-0383. ; 11:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Degeneration alters the structural components of the disc and its mechanical behavior. Understanding this pathophysiological process is of great importance, as it may lead to back pain. However, non-invasive methods to characterize the disc mechanics in vivo are lacking. Here, a potential method for measurements of the intradiscal deformation under stress is presented. The method utilizes a standard MRI protocol, commercial loading equipment, and registration software. The lumbar spine (L1/L2-L5/S1) of 36 human subjects was imaged with and without axial loading of the spine. The resulting images were registered, and changes in the images during the registration were displayed pixel-by-pixel to visualize the internal deformation of the disc. The degeneration grade, disc height, disc angle and tilt angle were determined and correlated with the deformation using multivariate regression analysis. The largest deformation was found at the lower lumbar spine, and differences in regional behaviors between individual discs were found. Weak to moderate correlations between the deformation and different disc characteristics were found, where the degeneration grade and tilt angle were the main contributing factors. To conclude, the image-based method offers a potential tool to study the pathophysiological process of the disc.
  •  
24.
  • Johansson, Jens, et al. (författare)
  • Brain diffusion MRI with multiplexed sensitivity encoding for reduced distortion in a pediatric patient population
  • 2022
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 0730-725X. ; 87, s. 97-103
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Diffusion-weighted imaging (DWI) is a valuable tool for routine imaging of the pediatric brain. However, the commonly used single-shot (ss) echo-planar imaging (EPI) DWI sequence is prone to geometric distortions and T2*-blurring. This study aimed to investigate in a pediatric population the benefits of using multiplexed sensitivity-encoding (MUSE) without and with reversed polarity gradients (RPG) instead. Methods: This retrospective study compared image quality, geometric distortions, and diffusion values between three different approaches for DWI (ssEPI, MUSE, and RPG-MUSE) in 14 patients (median age = 4 (0.6–15) years, 11 males). Distortion levels were quantified and compared in two brain regions, i.e., the brain stem and the temporal lobes, using the Dice Coefficient and the Hausdorff Distance, with T2-weighted images as reference. Expected geometrical distortion was further evaluated by comparing the effective echo spacing between the DWI sequences. Apparent diffusion coefficient (ADC) values were determined in the genu of the corpus callosum and the optic nerves. Two raters graded overall image quality and image distortions on a Likert scale. Results: Distortion levels assessed with Dice coefficient and Hausdorff distance were significantly lower for MUSE (p < 0.05) and RPG-MUSE (p < 0.01) compared to ssEPI. No significant difference in ADC values was observed between methods. The RPG-MUSE method was graded by one rater as significantly higher in overall image quality than ssEPI (p < 0.05) and by both raters as significantly lower in levels of image distortions than both MUSE (p < 0.05) and ssEPI (p < 0.05). These results were in agreement with the reduced effective echo spacing was that was attained with MUSE and RPG-MUSE. Conclusion: For imaging of the pediatric brain, MUSE and even more so RPG-MUSE offers both improved geometric fidelity and image quality compared to ssEPI. © 2022 The Authors
  •  
25.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-25 av 47
Typ av publikation
tidskriftsartikel (44)
konferensbidrag (3)
Typ av innehåll
refereegranskat (44)
övrigt vetenskapligt/konstnärligt (3)
Författare/redaktör
Lagerstrand, Kerstin ... (47)
Brisby, Helena, 1965 (20)
Arvidsson, Jonathan (5)
Bech-Hanssen, Odd, 1 ... (4)
Starck, Göran (3)
Maier, Stephan E, 19 ... (3)
visa fler...
Bobbio, Emanuele (3)
Johansson, Jens (3)
de Lange, Charlotte, ... (3)
Baranto, Adad, 1966 (2)
Stokland, Eira (2)
Ziegelitz, Doerthe (2)
Nordanstig, Joakim (2)
Bergh, Niklas, 1979 (2)
Falkenberg, Mårten, ... (2)
Bollano, Entela, 197 ... (2)
Himmelman, Jakob (2)
Petersson, Magnus (1)
Myklebust, T. A. (1)
Johansson, A (1)
Vandenput, Liesbeth, ... (1)
Lorentzon, Mattias, ... (1)
Johansson, E (1)
Nordström, Fredrik, ... (1)
Bennet, W (1)
Sansone, Mikael (1)
Hansson, Sverker, 19 ... (1)
Sixt, Rune (1)
Hansson, S (1)
Öhman, Annika (1)
Agerskov, Simon (1)
Wikkelsö, Carsten, 1 ... (1)
Tullberg, Mats, 1965 (1)
Björkman-Burtscher, ... (1)
Johannsson, Gudmundu ... (1)
Karason, Kristjan, 1 ... (1)
Grimby-Ekman, Anna, ... (1)
Andersson, Linnéa (1)
Johansson-Synnergren ... (1)
Skoglund, Thomas, 19 ... (1)
Sunnegårdh, Jan, 194 ... (1)
Kahl, Fredrik, 1972 (1)
Chodorowski, Artur, ... (1)
Alvén, Jennifer, 198 ... (1)
Hamrin Senorski, Eri ... (1)
Jensen, J. (1)
Farahmand, Dan (1)
Oldfors, Anders, 195 ... (1)
Jalnefjord, Oscar, 1 ... (1)
Dangardt, Frida, 197 ... (1)
visa färre...
Lärosäte
Göteborgs universitet (47)
Chalmers tekniska högskola (3)
Språk
Engelska (47)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (47)
Teknik (3)
Naturvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy