SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Li Xiaohui) srt2:(2008-2009)"

Sökning: WFRF:(Li Xiaohui) > (2008-2009)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Li, Xiaohui, et al. (författare)
  • Concentric silicon micro-ring resonators with enhanced transmission notch depth
  • 2008
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE.
  • Konferensbidrag (refereegranskat)abstract
    • In this work, we have analyzed, fabricated and demonstrated concentric micro-ring resonators in silicon-on-insulator (SOI) structure for enhanced transmission notches. The operation principles of the concentric ring resonators are studied by time-domain coupled-mode theory. Directional coupling between concentric rings offers another freedom in designing deep notch optical filters and ultra-sensitive biosensors. The finite-difference-time-domain (FDTD) simulations have shown the improvement of the notch depth, evenly distributed mode field and the effect of the resonance shift. The device is demonstrated in silicon-on-insulator structure. Transmission notch depth improvement of ~ 15dB is demonstrated for the 21-20.02-μm-radius double-ring structure comparing with the single 21-μm-radius ring.
  •  
2.
  • Li, Xiaohui, et al. (författare)
  • Sensitive label-free and compact biosensor based on concentric silicon-on-insulator microring resonators
  • 2009
  • Ingår i: Applied Optics. - 1559-128X .- 2155-3165. ; 48:25, s. F90-F94
  • Tidskriftsartikel (refereegranskat)abstract
    • We propose an ultracompact parallel label-free biosensor based on concentric silicon-on-insulator microring resonators. Our numerical studies show that the proposed biosensor offers higher sensitivity and a larger detection area than conventional single-ring-based sensors. We analyze the detection sensitivity of the DNA hybridization by immobilizing the probe on top of the double concentric ring resonators and in the ring-ring air gap. For a concentric double-ring system with an area of 27: 646 mu m(2), the bulk detection sensitivity is 683 nm RIU-1. The sensitive uniformity of the system related to the optical field distribution is also studied.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
konferensbidrag (1)
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Qiu, Min (2)
Zhang, Ziyang (2)
Li, Xiaohui (2)
Wang, Tao (1)
Li, Qiang (1)
Su, Yikai (1)
visa fler...
Su, Y. (1)
Liu, Fangfei (1)
Qin, Shenying (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy