SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lilja Karin) srt2:(2000-2004)"

Sökning: WFRF:(Lilja Karin) > (2000-2004)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Amer-Wåhlin, Isis, et al. (författare)
  • Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial
  • 2001
  • Ingår i: The Lancet. - 1474-547X. ; 358:9281, s. 534-538
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Previous studies indicate that analysis of the ST waveform of the fetal electrocardiogram provides information on the fetal response to hypoxia. We did a multicentre randomised controlled trial to test the hypothesis that intrapartum monitoring with cardiotocography combined with automatic ST-waveform analysis results in an improved perinatal outcome compared with cardiotocography alone. METHODS: At three Swedish labour wards, 4966 women with term fetuses in the cephalic presentation entered the trial during labour after a clinical decision had been made to apply a fetal scalp electrode for internal cardiotocography. They were randomly assigned monitoring with cardiotocography plus ST analysis (CTG+ST group) or cardiotocography only (CTG group). The main outcome measure was rate of umbilical-artery metabolic acidosis (pH <7.05 and base deficit >12 mmol/L). Secondary outcomes included operative delivery for fetal distress. Results were first analysed according to intention to treat, and secondly after exclusion of cases with severe malformations or with inadequate monitoring. FINDINGS: The CTG+ST group showed significantly lower rates of umbilical-artery metabolic acidosis than the cardiotocography group (15 of 2159 [0.7%] vs 31 of 2079 [2%], relative risk 0.47 [95% CI 0.25-0.86], p=0.02) and of operative delivery for fetal distress (193 of 2519 [8%] vs 227 of 2447 [9%], 0.83 [0.69-0.99], p=0.047) when all cases were included according to intention to treat. The differences were more pronounced after exclusion of 291 in the CTG+ST group and 283 in the CTG group with malformations or inadequate recording. INTERPRETATION: Intrapartum monitoring with cardiotocography combined with automatic ST-waveform analysis increases the ability of obstetricians to identify fetal hypoxia and to intervene more appropriately, resulting in an improved perinatal outcome.
  •  
3.
  • Strandberg, Karin, et al. (författare)
  • A sensitive immunochemical assay for measuring the concentration of the activated protein C-protein C inhibitor complex in plasma: use of a catcher antibody specific for the complexed/cleaved form of the inhibitor
  • 2001
  • Ingår i: Thrombosis and Haemostasis. - 0340-6245. ; 86:2, s. 604-610
  • Tidskriftsartikel (refereegranskat)abstract
    • Activated protein C (APC) is a serine proteinase that regulates blood coagulation. In plasma it is inhibited mainly by the protein C inhibitor (PCI). The plasma concentrations of APC-PCI complex is increased in hypercoagulative states such as deep venous thrombosis. Formation of the APC-PCI complex induces a drastic conformational change in PCI that exposes new epitopes (neoepitopes) on the molecule. We have devised a simple immunofluorometric sandwich assay for measurements of the concentrations of APC-PCI complex, employing as the catcher, a monoclonal antibody that has a high affinity (K(D) = 4 x 10(-11) M) for a complexation-specific neoepitope that is expressed on PCI. A monoclonal antibody against protein C is employed as the tracer. The method gives a linear dose-response curve (0.06-50 microg/l), has a low detection limit (0.06 microg/l) and no crossreactivity with native PCI at physiologic plasma concentrations. We have now determined the concentration of the APC-PCI complex in healthy individuals.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy