SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(McFarland K. S.) srt2:(2010-2014)"

Sökning: WFRF:(McFarland K. S.) > (2010-2014)

  • Resultat 1-12 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aaltonen, T., et al. (författare)
  • Combination of Tevatron Searches for the Standard Model Higgs Boson in the W+W- Decay Mode
  • 2010
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 104:6, s. 061802-
  • Tidskriftsartikel (refereegranskat)abstract
    • We combine searches by the CDF and D0 Collaborations for a Higgs boson decaying to W+W-. The data correspond to an integrated total luminosity of 4.8 (CDF) and 5.4 (D0) fb(-1) of p (p) over bar collisions at root s = 1.96 TeV at the Fermilab Tevatron collider. No excess is observed above background expectation, and resulting limits on Higgs boson production exclude a standard model Higgs boson in the mass range 162-166 GeV at the 95% C.L.
  •  
2.
  • Aaltonen, T., et al. (författare)
  • Evidence for a Particle Produced in Association with Weak Bosons and Decaying to a Bottom-Antibottom Quark Pair in Higgs Boson Searches at the Tevatron
  • 2012
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 109:7, s. 071804-
  • Tidskriftsartikel (refereegranskat)abstract
    • We combine searches by the CDF and D0 Collaborations for the associated production of a Higgs boson with a W or Z boson and subsequent decay of the Higgs boson to a bottom-antibottom quark pair. The data, originating from Fermilab Tevatron p (p) over bar collisions at root s = 1.96 TeV, correspond to integrated luminosities of up to 9.7 fb(-1). The searches are conducted for a Higgs boson with mass in the range 100-150 GeV/c(2). We observe an excess of events in the data compared with the background predictions, which is most significant in the mass range between 120 and 135 GeV/c(2). The largest local significance is 3.3 standard deviations, corresponding to a global significance of 3.1 standard deviations. We interpret this as evidence for the presence of a new particle consistent with the standard model Higgs boson, which is produced in association with a weak vector boson and decays to a bottom-antibottom quark pair.
  •  
3.
  • Aaltonen, T., et al. (författare)
  • Combination of CDF and D0 measurements of the W boson helicity in top quark decays
  • 2012
  • Ingår i: Physical Review D. - 1550-7998 .- 1550-2368. ; 85:7, s. 071106-
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7-5.4 fb(-1) of p (p) over bar collisions collected during Run II of the Fermilab Tevatron collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f(0)) and right-handed (f(+)) helicities, we find f(0) = 0.722 +/- 0.081[+/- 0.062(stat) +/- 0.052(syst)] and f(+) = -0.033 +/- 0.046[+/- 0.034(stat) +/- 0.031(syst)]. Combining measurements where one of the helicity fractions is fixed to the value expected in the standard model, we find f(0) = 0.682 +/- 0.057[+/- 0.035(stat) +/- 0.046(syst)] for fixed f(+) and f(+) = -0.015 +/- 0.035[+/- 0.018(stat) +/- 0.030(syst)] for fixed f(0). The results are consistent with standard model expectations.
  •  
4.
  • Ederle, Joerg, et al. (författare)
  • Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial
  • 2010
  • Ingår i: The Lancet. - 1474-547X. ; 375:9719, s. 985-997
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470. Findings The trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4.0%) events of disabling stroke or death in the stenting group compared with 27 (3.2%) events in the endarterectomy group (hazard ratio [HR] 1.28, 95% CI 0.77-2.11). The incidence of stroke, death, or procedural myocardial infarction was 8.5% in the stenting group compared with 5.2% in the endarterectomy group (72 vs 44 events; HR 1.69, 1.16-2.45, p=0.006), Risks of any stroke (65 vs 35 events; HR 1.92, 1.27-2.89) and all-cause death (19 vs seven events; HR 2.76, 1.16-6.56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0.0197). Interpretation Completion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery.
  •  
5.
  •  
6.
  • McFarland, B. K., et al. (författare)
  • Ultrafast X-ray Auger probing of photoexcited molecular dynamics
  • 2014
  • Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 5, s. 4235-
  • Tidskriftsartikel (refereegranskat)abstract
    • Molecules can efficiently and selectively convert light energy into other degrees of freedom. Disentangling the underlying ultrafast motion of electrons and nuclei of the photoexcited molecule presents a challenge to current spectroscopic approaches. Here we explore the photoexcited dynamics of molecules by an interaction with an ultrafast X-ray pulse creating a highly localized core hole that decays via Auger emission. We discover that the Auger spectrum as a function of photoexcitation-X-ray-probe delay contains valuable information about the nuclear and electronic degrees of freedom from an element-specific point of view. For the nucleobase thymine, the oxygen Auger spectrum shifts towards high kinetic energies, resulting from a particular C-O bond stretch in the pi pi* photoexcited state. A subsequent shift of the Auger spectrum towards lower kinetic energies displays the electronic relaxation of the initial photoexcited state within 200 fs. Ab-initio simulations reinforce our interpretation and indicate an electronic decay to the n pi* state.
  •  
7.
  • Farrell, J. P., et al. (författare)
  • Ultrafast X-ray probe of nucleobase photoprotection
  • 2012
  • Ingår i: Quantum Electronics and Laser Science Conference. - 9781467318396 ; , s. 6327153-
  • Konferensbidrag (refereegranskat)abstract
    • We will present first results of a UV-pump X-ray-probe study of the photoprotection mechanism of thymine. The experiment used element specific Auger spectroscopy and was carried out at the LCLS.
  •  
8.
  • McFarland, B. K., et al. (författare)
  • Probing nucleobase photoprotection with soft x-rays
  • 2013
  • Ingår i: XVIIITH INTERNATIONAL CONFERENCE ON ULTRAFAST PHENOMENA. - : EDP Sciences. - 9782759809561 ; , s. 07004-
  • Konferensbidrag (refereegranskat)abstract
    • Nucleobases absorb strongly in the ultraviolet region, leading to molecular excitation into reactive states. The molecules avoid the photoreactions by funnelling the electronic energy into less reactive states on an ultrafast timescale via non-Born-Oppenheimer dynamics. Current theory on the nucleobase thymine discusses two conflicting pathways for the photoprotective dynamics. We present our first results of our free electron laser based UV-pump soft x-ray-probe study of the photoprotection mechanism of thymine. We use the high spatial sensitivity of the Auger electrons emitted after the soft x-ray pulse induced core ionization. Our transient spetra show two timescales on the order of 200 fs and 5 ps, in agreement with previous (all UV) ultrafast experiments. The timescales appear at different Auger kinetic energies which will help us to decipher the molecular dynamics.
  •  
9.
  • Murphy, B. F., et al. (författare)
  • Femtosecond X-ray-induced explosion of C-60 at extreme intensity
  • 2014
  • Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 5
  • Tidskriftsartikel (refereegranskat)abstract
    • Understanding molecular femtosecond dynamics under intense X-ray exposure is critical to progress in biomolecular imaging and matter under extreme conditions. Imaging viruses and proteins at an atomic spatial scale and on the time scale of atomic motion requires rigorous, quantitative understanding of dynamical effects of intense X-ray exposure. Here we present an experimental and theoretical study of C-60 molecules interacting with intense X-ray pulses from a free-electron laser, revealing the influence of processes not previously reported. Our work illustrates the successful use of classical mechanics to describe all moving particles in C-60, an approach that scales well to larger systems, for example, biomolecules. Comparisons of the model with experimental data on C-60 ion fragmentation show excellent agreement under a variety of laser conditions. The results indicate that this modelling is applicable for X-ray interactions with any extended system, even at higher X-ray dose rates expected with future light sources.
  •  
10.
  • Cryan, J P, et al. (författare)
  • Molecular frame Auger electron energy spectrum from N2
  • 2012
  • Ingår i: Journal of Physics B. - : IOP Publishing. - 0953-4075 .- 1361-6455. ; 45:5, s. 055601-
  • Tidskriftsartikel (refereegranskat)abstract
    • Here we present the first angle-resolved, non-resonant (normal) Auger spectra for impulsively aligned nitrogen molecules. We have measured the angular pattern of Auger electron emission following K -shell photoionization by 1.1 keV photons from the Linac Coherent Light Source (LCLS). Using strong-field-induced molecular alignment to make molecular frame measurements is equally effective for both repulsive and quasi-bound final states. The capability to resolve Auger emission angular distributions in the molecular frame of reference provides a new tool for spectral assignments in congested Auger electron spectra that takes advantage of the symmetries of the final diction states. Based on our experimental results and theoretical predictions, we propose the assignment of the spectral features in the Auger electron spectrum.
  •  
11.
  • Cryan, James P., et al. (författare)
  • Auger Electron Angular Distribution of Double Core-Hole States in the Molecular Reference Frame
  • 2010
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 105:8, s. 083004-
  • Tidskriftsartikel (refereegranskat)abstract
    • The Linac Coherent Light Source free electron laser is a source of high brightness x rays, 2×1011 photons in a ∼5  fs pulse, that can be focused to produce double core vacancies through rapid sequential ionization. This enables double core vacancy Auger electron spectroscopy, an entirely new way to study femtosecond chemical dynamics with Auger electrons that probe the local valence structure of molecules near a specific atomic core. Using 1.1 keV photons for sequential x-ray ionization of impulsively aligned molecular nitrogen, we observed a rich single-site double core vacancy Auger electron spectrum near 413 eV, in good agreement with ab initio calculations, and we measured the corresponding Auger electron angle dependence in the molecular frame.
  •  
12.
  • Glownia, James M., et al. (författare)
  • Time-resolved pump-probe experiments at the LCLS
  • 2010
  • Ingår i: Optics Express. - 1094-4087. ; 18:17, s. 17620-17630
  • Tidskriftsartikel (refereegranskat)abstract
    • The first time-resolved x-ray/optical pump-probe experiments at the SLAC Linac Coherent Light Source (LCLS) used a combination of feedback methods and post-analysis binning techniques to synchronize an ultrafast optical laser to the linac-based x-ray laser. Transient molecular nitrogen alignment revival features were resolved in time-dependent x-ray-induced fragmentation spectra. These alignment features were used to find the temporal overlap of the pump and probe pulses. The strong-field dissociation of x-ray generated quasi-bound molecular dications was used to establish the residual timing jitter. This analysis shows that the relative arrival time of the Ti:Sapphire laser and the x-ray pulses had a distribution with a standard deviation of approximately 120 fs. The largest contribution to the jitter noise spectrum was the locking of the laser oscillator to the reference RF of the accelerator, which suggests that simple technical improvements could reduce the jitter to better than 50 fs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-12 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy