SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Surrey E.)
 

Sökning: WFRF:(Surrey E.) > (2009) > Anomalous and class...

Anomalous and classical neutral beam fast ion diffusion on JET

Baranov, Y. F. (författare)
Jenkins, I (författare)
Alper, B (författare)
visa fler...
Challis, D (författare)
Conroy, S (författare)
Uppsala universitet,Institutionen för neutronforskning
Kiptily, V (författare)
Ongena, J (författare)
Popovichev, S (författare)
Smeulders, P (författare)
Surrey, E (författare)
Zastrow, K.-D. (författare)
visa färre...
 (creator_code:org_t)
2009-03-18
2009
Engelska.
Ingår i: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 51:4, s. 044004-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Trace tritium experiments (TTE) on JET were analysed using Monte Carlo modelling of the neutron emission resulting from the neutral beam injection (NBI) of short (similar to 300 ms) tritium ( T) beam blips into reversed shear, hybrid ELMy H-mode and L-mode deuterium plasmas for a wide range of plasma parameters. The calculated neutron fluxes from deuterium-tritium ( DT) reactions could only be made consistent with all plasmas by applying an artificial reduction of the T beam power in the modelling of between 20% and 40%. A similar discrepancy has previously been observed in both JET (Gorini et al 2004 Proc. 31st EPS Conf. on Plasma Physics ( London, UK) vol 28G (ECA)) and TFTR (Ruskov et al 1999 Phys. Rev. Lett. 82 924), although no mechanism has yet been found that could explain such a difference in the measured T beam power. Applying this correction in the T beam power, good agreement between calculated and measured DT neutron emission profiles was obtained in low to moderate line averaged density ((n(e)) over bar < 4 x 10(19) m(-3)) ELMy H-Mode plasmas assuming that the fast beam ions experience no, or relatively small, anomalous diffusion (D-an << 0.5 m(2) s(-1)). However, the modelled neutron profiles do not agree with measurements in higher density plasmas using the same assumption and the disagreement between the measured and calculated shape of the neutron profile increases with plasma density. In this paper it is demonstrated that large anomalous losses of fast ions have to be assumed in the simulations to improve agreement between experimental and simulated neutron profiles, characterized by the goodness of fit. Various types of fast ion losses are modelled to explain aspects of the data, though further investigation will be required in order to gain a more detailed understanding of the nature of those anomalous losses.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

Physics
Fysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy