1.
  • Flemme, Inger, 1947-, et al. (författare)
  • Quality of life related to shocks in ICD-recipients : a 5-year follow-up
  • 2006
  • Ingår i: 6th Annual Spring Meeting of the Working Group on Cardiovascular Nursing of the European Society of Cardiology and the Spring Meeting of the Norwegian National Society of Cardiovascular Nurses Bergen, Norway 5–6 May 2006. - London : Sage Publications. ; , s. S20-S20
  • Konferensbidrag (refereegranskat)abstract
    • Purpose: The purpose of this study was to describe QoL in relation to shocks and uncertainty in ICD-recipients and to identify predictors of QoL over a 5-year period. Methods: The design was prospective and longitudinal. Thirty-five patients who had lived with the ICD for at least five years had taken part in the study. All recipients had received their ICD as a form of secondary prevention. The questionnaires Mishel Uncertainty in Illness Scale – community version (MUIS-C), Quality of Life Index – cardiac version (QLI-CV) were completed on three occasions: before implantation, at year 1 and at year 5 after implantation. Self-reported number of shocks between the implantation and year 1 and between year 1 and year 5 were described. Data were analyzed by descriptive as well as analytical statistics. Results: In general, QoL was lower at year 1 than before implantation (p = 0.033). A decrease in the socio-economic domain was observed at year 1 (p = 0.006) but improved again at year 5 (p = 0.027) although it remained below the value before implantation. ICD recipient’s satisfaction with the family domain decreased from the time before ICD implantation (p = < 0.001) and from year 1 (p = 0.039) to year 5 after implantation. A decrease in overall uncertainty was observed at year 5 in relation to year 1 (p = 0.009). The longer the ICD recipient had lived with the device, the greater the risk of receiving a shock. However, ICD recipients who received shocks reported being less troubled by them over time. Uncertainty was identified as a predictor of low QoL. Conclusion: The recipients reported a higher level of QoL at year 5 than at year 1. QoL was reasonably good 5 years after implantation and the ICD recipient felt more secure and perceived their ICD as a lifesaver.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
konferensbidrag (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Fridlund, Bengt (1)
Edvardsson, Nils (1)
Jinhage, Britt-Marie (1)
Flemme, Inger, 1947- (1)
Hinic, Hansi, 1961- (1)
Dalman, Margareta (1)
Lärosäte
Högskolan i Halmstad (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy