  • Sjögren, Göran, et al. (författare)
  • Clinical evaluation of all-ceramic crowns (Dicor) in general practice.
  • 1999
  • Ingår i: The Journal of prosthetic dentistry (Print). - 0022-3913 .- 1097-6841. ; 81:3, s. 277-284
  • Tidskriftsartikel (refereegranskat)abstract
    • STATEMENT OF PROBLEM: There are few studies regarding all-ceramic full crowns placed by general practitioners; however, most dental restorations are carried out by general practitioners, and their clinical performance may be of particular interest. PURPOSE: Ninety-eight all-ceramic Dicor crowns placed in 46 patients regularly visiting a general practice were evaluated with the California Dental Association's (CDA) criteria. Mean and median ages of the crowns were 6.1 and 5.8 years, respectively (range 1.4 to 10. 9 years). Crowns were luted with either a glass ionomer, zinc phosphate, or resin composite cement. RESULTS. Of the 98 crowns, 82% were rated satisfactory. For marginal integrity, 51% were rated excellent. Fracture was registered in 14 all crowns, and 1 endodontically treated tooth with a Dicor crown was extracted because of root fracture; of the remaining 83 crowns, 55% were rated excellent for color. Corresponding figures for surface and anatomic form were 46% and 23%, respectively. The most common finding was slightly rough surfaces (64%). No statistically significant difference was observed for fracture rates obtained when the crowns luted with different luting agents were compared (P >.05). There was no more plaque or bleeding on probing (P >.05) in connection with the Dicor crowns than in the control surfaces.
  •  
2.
  • Sjögren, Göran, et al. (författare)
  • Clinical examination of leucite-reinforced glass-ceramic crowns (Empress) in general practice : a retrospective study
  • 1999
  • Ingår i: International Journal of Prosthodontics. - 0893-2174 .- 1139-9791. ; 12:2, s. 122-128
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The purpose of this study was to retrospectively evaluate leucite reinforced-glass ceramic crowns (Empress) placed in patients who regularly visit general practices. MATERIALS AND METHODS: One hundred ten Empress crowns, placed in 29 patients who visited a general practice on a regular basis, were evaluated according to the California Dental Association's (CDA) quality evaluation system. In addition, the occurrence of plaque and certain gingival conditions was evaluated. All crowns were luted with resin composite cement. The mean and median years in function for the crowns were 3.6 and 3.9 years, respectively. RESULTS: Based on the CDA criteria, 92% of the 110 crowns were rated "satisfactory." Eighty-six percent were given the CDA rating "excellent" for margin integrity. Fracture was registered in 6% of the 110 crowns. Of the remaining 103 crowns, the CDA rating excellent was given to 74% for anatomic form, 86% for color, and 90% for surface. No significant differences (P > 0.05) were observed regarding fracture rates between anterior and posterior crowns. With regard to the occurrence of plaque and bleeding on probing, no significant differences (P > 0.05) were observed between the Empress crowns and the controls. CONCLUSION: Most of the fractured crowns had been placed on molars or premolars. Although the difference between anterior and posterior teeth was not statistically significant with respect to the fracture rates obtained, the number of fractured crowns placed on posterior teeth exceeded that of those placed on anterior teeth. The difference between the fracture rates may have clinical significance, and the risk of fracture has to be taken into consideration when placing crowns on teeth that are likely to be subjected to high stress levels.
  •  
3.
  • Källtorp, Mia, et al. (författare)
  • In vivo cell recruitment, cytokine release and chemiluminescence response at gold, and thiol functionalized surfaces.
  • 1999
  • Ingår i: Biomaterials. - 0142-9612. ; 20:22, s. 2123-37
  • Tidskriftsartikel (refereegranskat)abstract
    • Hydroxylated and methylated surfaces were prepared by the self-assembled monolayer technique (SAM) of alkane thiols on gold. The surfaces were used to evaluate the influence of implant surface chemistry on protein deposition and inflammatory cell response. Implants were inserted subcutaneously in the rat for 3 and 24 h. The surface chemical properties influenced the in vitro rat plasma protein adsorption (ellipsometry/antibody) with few exceptions (albumin not found and fibrinogen always found). The number of recruited cells and their distribution (DNA from implant versus from exudate) was influenced by the different chemistries at 24 h, but not at 3 h. HIS48+, ED1+, ED2+ and small numbers of CD5+ cells were present in the exudate at both time periods (flow cytometry). The cellular oxidative metabolism was low, although cells on -OH surfaces responded with the highest phorbol ester-stimulated chemiluminescence (CL)/DNA. The levels of cytokines IL-1alpha, IL-1beta and TNFalpha (ELISA) were not influenced by material surface chemistry. Sham operated sites had a higher cytokine concentration/DNA compared with exudates from an implant milieu. The results of this study show that surface chemical functionalization modifies specific events in the inflammatory response around implants in soft tissues.
  •  
4.
  • Hong, Jaan, et al. (författare)
  • A new in vitro model to study interaction between whole blood and biomaterials. Studies of platelet and coagulation activation and the effect of aspirin
  • 1999
  • Ingår i: Biomaterials. - : Elsevier. - 0142-9612 .- 1878-5905. ; 20:7, s. 603-611
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed a versatile in vitro chamber model with a double purpose: first, to be able to study mechanisms of bio- incompatibility, and, second, to test biomaterials at all levels of interactions, in whole blood. The use of biomaterials in the form of microscope slides as walls in the chamber makes it possible to analyse both the biomaterial surface with regard to protein and cell binding, as well as the molecular events taking place in the fluid. Incubation of blood in the chamber, for 60 min at 37°C resulted in the rapid binding of complement and coagulation proteins and of leukocytes and platelets to polyvinylchloride (PVC) slides. The cells formed a layer which more or less covered the underlying surface. Unlike complement activation, as reflected by soluble C3a and C5b-9, the thrombin—antithrombin formation was completely nullified in cell-depleted plasma. Despite the fact that throm- bin—antithrombin generation was also negligible in platelet-rich plasma, inhibition of platelet aggregation on the material surface with aspirin resulted in suppressed generation of thrombin—antithrombin complexes. Taken together, the coagulation activation in the chamber was dependent on the presence of blood cells which suggests that bound/aggregated platelets initiate a sequence of events involving leukocytes that results in coagulation activation. 
  •  
5.
  •  
6.
  • Lundberg, F., et al. (författare)
  • Protein depositions on one hydrocephalus shunt and on fifteen temporary ventricular catheters
  • 1997
  • Ingår i: Acta Neurochirurgica. - 0001-6268. ; 139:8, s. 734-742
  • Tidskriftsartikel (refereegranskat)abstract
    • Biomaterials are commonly used in modern medicine. Proteins are adsorbed to the surface of the biomaterial immediately after insertion. This report demonstrates the presence of adsorbed proteins in one infected cerebrospinal shunt from a child with hydrocephalus and on fifteen temporary ventricular catheters from adult patients with spontaneous or traumatic brain injuries. Depositions of vitronectin, fibrinogen and thrombospondin-fibronectin to some extent - on the shunt surface was imaged by field-emission scanning electron microscopy. Vitronectin, fibronectin, fibrinogen, and thrombospondin on the ventricular catheters were shown with radio-actively labelled antibodies. Furthermore, protein adsorption from human cerebrospinal fluid to heparinized and unheparinized polymers was studied under flowing conditions in vitro. On heparinized polymer, significantly reduced levels of vitronectin, fibronectin, and thrombospondin were exposed, as measured after 4 hours in vitro perfusion. After 24 hours perfusion, the differences in protein exposition between heparinized and unheparinized polymers were substantially reduced.
  •  