SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0960 7692 srt2:(2000-2004)"

Sökning: L773:0960 7692 > (2000-2004)

  • Resultat 1-40 av 40
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Valentin, Lil, et al. (författare)
  • Comparison of 'pattern recognition' and logistic regression models for discrimination between benign and malignant pelvic masses: a prospective cross validation
  • 2001
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 18:4, s. 357-365
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To test prospectively the diagnostic performance of two logistic regression models for calculation of individual risk of malignancy in adnexal tumors (the 'Tailor model' and the 'Timmerman model'), and to compare them to that of 'pattern recognition' (subjective evaluation of the gray-scale ultrasound image and color Doppler ultrasound examination). DESIGN: Consecutive women with a pelvic mass judged clinically to be of adnexal origin underwent preoperative ultrasound examination including color and spectral Doppler examination. The same examination techniques and definitions as those used in the studies in which the logistic regression models had been created were used. The Tailor model was tested in 133 women (35 of whom hada malignancy) and the Timmerman model in 82 women (29 of whom had a malignancy). A subset of 79 women (28 of whom had a malignancy) was used to compare the performance of the Tailor model and the Timmerman model by calculating and comparing the areas under the receiver operating characteristics curves of the two models. Sensitivity and specificity with regard to malignancy were calculated for all three methods. RESULTS: Pattern recognition performed better than the two logistic regression models (sensitivity around 85%, specificity around 90%). Using a risk of malignancy of > 50% to indicate malignancy (as suggested in the original publications), the sensitivity of the Tailor model was 69% and the specificity 88% (n = 133). The corresponding values for the Timmerman model were 62% and 79% (n = 82). The receiver operating characteristics curves showed the two logistic regression models to have similar diagnostic properties (area under the curve, 0.87 vs. 0.84; P = 0.25; n = 79). The diagnostic performance of the mathematical models was much poorer in this study than in those in which the models had been created. CONCLUSION: The poor diagnostic performance of the mathematical models can probably be explained by subtle differences in definitions and examination technique and by differences between the original tumor populations and the study population. For mathematical models to be generally useful, they probably need to be created on the basis of a very large number of tumors, and the variables in the model must be unequivocally defined and the examination technique meticulously standardized.
  •  
3.
  • Bergelin, I., et al. (författare)
  • Patterns of normal change in cervical length and width during pregnancy in nulliparous women: a prospective, longitudinal ultrasound study
  • 2001
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 18:3, s. 217-222
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To determine what constitutes normal changes in the uterine cervix visible at transvaginal ultrasound examination from 24 gestational weeks until delivery in nulliparous women delivering at term. DESIGN: Cervical length and width were measured using transvaginal ultrasound, and the inner cervical os was assessed as being closed or open every 2 weeks from gestational week 24 until delivery in 19 healthy nulliparae delivering at term. RESULTS: In all but one woman cervical length decreased, and in all but one woman cervical width increased, with advancing gestation. Three patterns of change in cervical length were observed: a continuous decrease ( n = 10), an accelerated shortening rate after approximately 30 gestational weeks ( n = 5), or a sudden drop in length between the last two examinations ( n = 3). The median rate of decrease in cervical length was 1 (range, 0.6-1.9) mm/week for women with continuous shortening of the cervix. For women with accelerated shortening the corresponding figure was 2.2 (range, 1.8-2.7) mm/week after the start of accelerated shortening. Two patterns of increase in cervical width (cervical broadening) were noted: a continuous increase ( n = 12), or an accelerated broadening rate from around 32 weeks ( n = 6). The median rate of increase in cervical width was 0.8 (range, 0.3-2.0) mm/week for women with continuous broadening of the cervix. For women with accelerated broadening rate the corresponding figure was 1.7 (range, 1.0-6.4) mm/week after the start of increased broadening rate. Opening of the internal cervical os was observed at least once in eight of the 19 women (42%) and was first observed at 30 gestational weeks. Dynamic changes (i.e. opening and closing of the inner cervical os during examination) were seen in six women (32%) and were first detected at 31 gestational weeks. CONCLUSIONS: There are different patterns of normal change in cervical length and width during pregnancy in nulliparous women. This must be taken into account if repeated ultrasound examinations of the cervix during pregnancy are used to identify nulliparae at increased risk of preterm delivery.
  •  
4.
  • Epstein, Elisabeth, et al. (författare)
  • Rebleeding and endometrial growth in women with postmenopausal bleeding and endometrial thickness <5 mm managed by dilatation and curettage or ultrasound follow-up: a randomized controlled study
  • 2001
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 18:5, s. 499-504
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To compare the frequency of rebleeding and endometrial growth during a 12-month follow-up period between women with postmenopausal bleeding and an endometrial thickness < 5 mm managed by dilatation and curettage, and those managed by ultrasound follow-up. DESIGN: Consecutive women with postmenopausal bleeding and an endometrial thickness < 5 mm were randomized to ultrasound follow-up after 3, 6, and 12 months (n = 48) or to primary dilatation and curettage with ultrasound follow-up at 12 months (n = 49). At all follow-up examinations, the endometrial thickness was measured and the women were asked about rebleeding. The endometrium was sampled at the 12-month examination, if sampling had not been performed previously because of rebleeding or endometrial growth. RESULTS: Rebleeding was reported by 33% (16/48) of the women in the ultrasound group and by 21% (10/48) of those in the dilatation and curettage group (P = 0.17). Endometrial growth to >or= 5 mm was found in 21% (10/48) of the women in the ultrasound group and in 10% (5/48) of those in the dilatation and curettage group (P = 0.16). No endometrial pathology was found in women with isolated rebleeding. Endometrial pathology during follow-up was found more often in women with endometrial growth than in those without (33% vs. 4%; P = 0.008). CONCLUSION: Rebleeding and endometrial growth are common during a follow-up period of 12 months in women with postmenopausal bleeding and an endometrial thickness < 5 mm, irrespective of whether or not dilatation and curettage is primarily carried out. If these women are managed by ultrasound follow-up, endometrial sampling should be performed if the endometrium grows, but not necessarily in the case of rebleeding without endometrial growth.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Brodszki, Jana, et al. (författare)
  • Can the degree of retrograde diastolic flow in abnormal umbilical artery flow velocity waveforms predict pregnancy outcome?
  • 2002
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 19:3, s. 229-234
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Reverse end-diastolic flow is the most pathological type of the umbilical artery flow velocity waveform. We aimed to investigate whether additional prognostic information can be obtained from umbilical artery waveforms in cases with reverse end-diastolic flow. SUBJECTS AND METHODS: Umbilical artery Doppler velocity waveforms from 44 fetuses with reverse end-diastolic flow were analyzed and the following parameters measured: the highest amplitude and the area below the maximum velocity curve of forward and reverse flow (A, B and C, D, respectively) and the duration of forward and reverse flow (Tc and Td, respectively). Ratios A/B, C/D and Tc/Td were calculated. The cut-off values for A/B, C/D and Tc/Td with the best predictive values for perinatal death were established with the help of receiver operating characteristics curves. The three curves were compared with each other. RESULTS: Of the three ratios, A/B and C/D had the best capacity to predict perinatal death. Both ratios had acceptable sensitivities, specificities and positive predictive values. In this regard, A/B and C/D were comparable. The cut-off values for A/B and C/D were 4.3 and 4.52, respectively. Survivors had I significantly higher A/B and C/D ratios than non-survivors (P = 0.0001 and 0.0003, respectively). Significantly more fetuses with A/B or C/D below the established cut-off values had pulsations in the venous system (P < 0.05). In fetuses with a gestational age < =210 gestational days the survival rate was significantly higher in those with A/B or C/D above the cut-off values (P = 0.03 and 0.003, respectively). CONCLUSIONS: The A/B or C/D ratio can be used for quantification of the reverse end-diastolic flow waveforms in the umbilical artery and may offer additional information to the evaluation of fetal condition.
  •  
9.
  •  
10.
  •  
11.
  • Dubiel, M, et al. (författare)
  • Blood redistribution in the fetal brain during chronic hypoxia
  • 2002
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 20:2, s. 117-121
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Studies on blood flow velocity in the fetal middle cerebral artery have revealed signs of brain sparing in chronic hypoxia. These signs of brain sparing can disappear in the terminal case, but whether this applies to the whole brain or only parts of it is unknown. Methods Velocity waveforms of the middle cerebral, anterior cerebral and posterior cerebral arteries were recorded in 221 pregnancies complicated by pregnancy-induced hypertension. The presence of brain sparing (pulsatility index < 2 standard deviations) was noted and correlated to outcome of pregnancy, including emergency operative intervention and/or neonatal distress. Results Signs of brain sparing in the anterior cerebral artery were found in 90 fetuses, and in the middle cerebral and posterior cerebral arteries in 52 and 65, respectively. Signs of brain sparing in the anterior cerebral artery showed the strongest relationship to adverse perinatal outcome. The anterior cerebral artery was the only vessel in which signs of brain sparing were predictive of perinatal mortality. Conclusions Velocimetry of the anterior cerebral artery appears to be superior to that of the middle cerebral and posterior cerebral arteries as a means to predict adverse perinatal outcome. Anterior cerebral artery brain sparing may therefore be less transitory than sparing in the middle cerebral and posterior cerebral arteries, possibly suggesting that the frontal lobes are spared longer than the lateral and occipital regions of the fetal brain.
  •  
12.
  • Epstein, Elisabeth, et al. (författare)
  • An algorithm including results of gray-scale and power Doppler ultrasound examination to predict endometrial malignancy in women with postmenopausal bleeding.
  • 2002
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 20:4, s. 370-376
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To determine if power Doppler ultrasound examination of the endometrium can contribute to a correct diagnosis of endometrial malignancy in women with postmenopausal bleeding and endometrium >/= 5 mm. METHODS: Eighty-three women with postmenopausal bleeding and endometrium >/= 5 mm underwent gray-scale and power Doppler ultrasound examination using predetermined, standardized settings. Suspicion of endometrial malignancy at gray-scale ultrasound examination (endometrial morphology) was noted, and the color content of the endometrium at power Doppler examination was estimated subjectively (endometrial color score). Computer analysis of the most vascularized area of the endometrium was done off-line in a standardized manner. Stepwise multivariate logistic regression analysis was carried out to determine which subjective and objective ultrasound and power Doppler variables satisfied the criteria to be included in a model to calculate the probability of endometrial malignancy. RESULTS: Endometrial thickness, vascularity index (vascularized area/endometrial area), and use of hormone replacement therapy (HRT) satisfied the criteria to be included in the model used to calculate the 'objective probability of endometrial malignancy'. Endometrial morphology, endometrial color score and HRT use satisfied the criteria to be included in the model to calculate the 'subjective probability of malignancy'. Endometrial thickness >/= 10.5 mm had a sensitivity with regard to endometrial cancer of 0.88 and a specificity of 0.61. At a fixed sensitivity of 0.88, the specificity of the 'objective probability of malignancy' (0.81) was superior to all other ultrasound and power Doppler variables (P = 0.001-0.02). The 'objective probability of malignancy' detected more malignancies at endometrium 5-15 mm than endometrial morphology (5/7 vs. 1/7, i.e. 0.71 vs. 0.14; P = 0.125) with a similar specificity (49/57 vs. 51/57, i.e. 0.86 vs. 0.89). CONCLUSION: Power Doppler ultrasound can contribute to a correct diagnosis of endometrial malignancy, especially if the endometrium measures 5-15 mm. The use of regression models including power Doppler results to estimate the risk of endometrial cancer deserves further development.
  •  
13.
  •  
14.
  • Epstein, Elisabeth, et al. (författare)
  • Transvaginal sonography, saline contrast sonohysterography and hysteroscopy for the investigation of women with postmenopausal bleeding and endometrium > 5 mm
  • 2001
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 18:2, s. 157-162
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To determine the ability of transvaginal ultrasound, with or without saline infusion, to detect focally growing lesions in the uterine cavity in women with postmenopausal bleeding and endometrium > 5 mm, and to determine the accuracy of conventional ultrasound, saline contrast sonohysterography and diagnostic hysteroscopy under general anesthesia to diagnose endometrial polyps, submucous myomas and uterine malignancy. DESIGN: In a prospective study, 105 women with postmenopausal bleeding and endometrium > 5 mm underwent conventional ultrasound examination and saline contrast sonohysterography. Diagnostic and operative hysteroscopy under general anesthesia was then performed. The presence of focally growing lesions and the type of lesion (endometrial polyp, submucous myoma, malignancy or unclear focal lesion) were noted at ultrasound examination and at hysteroscopy. RESULTS: There was almost perfect agreement (96%) between saline contrast sonohysterography and hysteroscopy in the diagnosis of focally growing lesions. Saline contrast sonohysterography and hysteroscopy both had a sensitivity of approximately 80% with regard to diagnosing endometrial polyps (false-positive rates of 24% and 6%, respectively), whereas conventional ultrasound missed half of the polyps (sensitivity, 49%; false-positive rate, 19%). Hysteroscopy was superior to both saline contrast sonohysterography and conventional ultrasound with regard to discriminating between benign and malignant lesions (sensitivity, 84%, 44%, and 60%; false-positive rate, 15%, 6% and 10%, respectively). The risk of malignancy was increased seven-fold (odds ratio, 7.3; 95% confidence interval, 1.9-27.8) in women with distension difficulties at saline contrast sonohysterography, and two thirds of the women with a poorly distensible uterine cavity had a malignant diagnosis. CONCLUSION: Saline contrast sonohysterography is as good as hysteroscopy at detecting focally growing lesions in the uterine cavity in women with postmenopausal bleeding. However, neither hysteroscopy nor saline contrast sonohysterography can reliably discriminate between benign and malignant focal lesions. Distension difficulties at saline contrast sonohysterography should raise a suspicion of malignancy.
  •  
15.
  • Gardiner, H, et al. (författare)
  • Ventriculovascular physiology of the growth-restricted fetus
  • 2001
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 18:1, s. 47-53
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To examine the mechanisms by which intrauterine growth restriction may influence later cardiovascular risk by comparing the ventriculovascular physiology of gestational age- and weight-matched growth-restricted and normal fetuses. DESIGN: A prospective longitudinal observational study of 20 normal fetuses studied from 20 weeks to term at monthly intervals was compared with a growth-restricted cohort examined in the interval between diagnosis and delivery. The last values before delivery of the growth-restricted cohort were compared with the normal cohort in two analyses matched for weight and for gestation. Arterial and venous vessel wall physiology and aortic pulse wave velocity were examined longitudinally in the thoracic descending aorta and inferior vena cava using an ultrasonic phase-locked echo-tracking system. Serial echocardiographic examinations were performed assessing structure, ventricular dimensions, function and Doppler flows. RESULTS: There was a linear increase in cardiac preload and relative pulse amplitude in the inferior vena cava with gestation. In normal fetuses, the aortic pulse wave velocity, maximum incremental and late decremental velocities increased with gestation whilst the relative pulse amplitude decreased reflecting falling distal impedance. In both age- and weight-matched analyses, the growth-restricted fetuses showed significantly reduced values reflecting the chronic fetal ventriculovascular responses to increased placental impedance. Pulse wave velocity increased with gestation and was significantly less in the growth-restricted cohort. CONCLUSIONS: Growth restriction is associated with abnormal ventriculovascular physiology that represents a successful adaptive response to raised placental impedance and reduction in wall stress as evidenced by the lower fetal pulse wave velocity in growth-restricted fetuses. However, whilst fetal adaptive mechanisms may aid survival they may result in cerebral and vascular abnormalities that prejudice later cardiovascular health.
  •  
16.
  •  
17.
  • Hernandez-Andrade, Edgar, et al. (författare)
  • Uterine artery score and perinatal outcome.
  • 2002
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 19:5, s. 438-442
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To evaluate a modified uterine artery score based on the pulsatility index and presence or absence of notching in the Doppler velocity waveform recorded from both uterine arteries in relation to the perinatal outcome. METHODS: A retrospective analysis was performed in 741 third-trimester high-risk pregnancies. The uterine artery score was constructed assigning one point to each abnormal parameter-high pulsatility index and presence of notch-thus ranging from 0 (normal findings in both uterine arteries) to 4 (notch and high pulsatility index in both uterine arteries). In a subgroup with lateral placenta (n = 359), two definitions of abnormal pulsatility index were compared. In the uniform uterine artery score, a pulsatility index > 1.20 in both uterine arteries was considered abnormal, disregarding the placental location; in the subgroup with lateral placenta, the high pulsatility index was defined as > 1.00 on the placental side and > 1.40 on the non-placental side. RESULTS: Receiver-operating characteristic curves did not reveal any difference in the diagnostic capacity between the group with a uniform uterine artery score and the subgroup with lateral placenta (P = 0.54). In the total material, the odds ratios and linear regression analysis showed an increased risk for an adverse perinatal outcome with increasing uterine artery score (P < 0.01). At a uterine artery score > 2, there was a significantly increased risk for operative delivery for fetal distress, neonatal intensive care unit admission, 5-min Apgar score < 7, preterm delivery and delivery of a small-for-gestational age fetus. CONCLUSION: In high-risk third-trimester pregnancies, Doppler velocity waveforms of the uterine arteries can be evaluated using the uterine artery score disregarding the placental location. The uterine artery score possesses a high predictive value regarding adverse perinatal outcome.
  •  
18.
  •  
19.
  • Hofstaetter, C, et al. (författare)
  • Venous Doppler velocimetry in the surveillance of severely compromised fetuses
  • 2002
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 20:3, s. 233-239
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To investigate whether venous Doppler velocimetric signs of cardiac decompensation might predict fetal demise in severely compromised fetuses. Material and methods This was a prospective study involving 154 growth-restricted fetuses, 37 of which were found to have reversed flow in the umbilical artery (BFC III). Doppler velocimetry of the right hepatic vein and ductus venosus were investigated serially and the presence of umbilical venous pulsations also registered. Only the final examination prior to birth or fetal demise was accepted for analysis and related to obstetric outcome defined as gestational age at birth, birth weight and perinatal mortality. In cases of BFC III the venous velocimetry of 15 nonsurviving fetuses was compared to that of the 22 survivors. Results There was a significant correlation between venous blood velocity and placental vascular resistance. In the right hepatic vein there was a significant decrease in peak systolic and end-systolic velocities and an increase of maximum velocity during atrial contraction and pulsatility (P < 0.05). A decrease of all velocities and increase of pulsatility were noted in the ductus venosus (P < 0.05). A reversed flow in the ductus venosus was found in 9/37 fetuses and double umbilical venous pulsations in 16/37 fetuses. However, the hepatic vein seemed to be a better predictor of impending mortality than the ductus venosus. Changes in diastolic venous blood velocity and a double pulsation in the umbilical vein were closely related to perinatal mortality, although these parameters did not provide a useful threshold to optimize the timing of delivery. Conclusion Diastolic venous velocimetry changes significantly in severely compromised fetuses. These changes might be of great clinical value in deciding on the timing of delivery to minimize damage to the fetus and newborn.
  •  
20.
  • Jarvela, IY, et al. (författare)
  • Intraobserver and interobserver variability of ovarian volume, gray-scale and color flow indices obtained using transvaginal three-dimensional power Doppler ultrasonography
  • 2003
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 21:3, s. 277-282
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To assess intraobserver and interobserver variability in ovarian volume and gray-scale and color flow index measurements using transvaginal, three-dimensional, power Doppler ultrasonography. Methods Eleven women (22 ovaries) were examined on day 8 of controlled ovarian hyperstimulation therapy, which was part of their in vitro fertilization treatment protocol. The patients were examined twice by the first observer and once by the second observer. The acquired volume datasets were analyzed using the VOCAL(TM) imaging program, enabling the assessment of ovarian volume, vascularization index (VI), flow index (FI), vascularization flow index (VFI) and mean grayness (MG). For these parameters the intraclass (intra-CC) and interclass (inter-CC) correlation coefficients, within-observer and between-observers repeatability coefficient (r) and limits of agreement were calculated. Results Both intraobserver and interobserver repeatability of ovarian volume measurements were considered very good with an intra-CC value of 1.00 and inter-CC value of 0.99, respectively. Also VI, FI, VFI and MG measurements were repeatable by a single observer, the intra-CC ranging from 0.82 to 0.91. The interobserver reproducibility was also good for VI, VFI and MG measurements (inter-CC values 0.73, 0.70 and 0.81, respectively), but for FI measurements the reproducibility was poor (inter-CC = 0.29, r = 7.87). Conclusions In general, the intraobserver reproducibility was better than interobserver reproducibility for all parameters. The volume assessments were reproducible both by one observer and by two separate observers. The intraobserver and interobserver variabilities were acceptable for VI, VFI and MG, whereas for FI the interobserver reproducibility was poor. Our results suggest that measurement of gray-scale and color Doppler flow indices is reproducible thus allowing them to be used in clinical practice and research.
  •  
21.
  • Kieler, H, et al. (författare)
  • Ultrasound and adverse effects
  • 2002
  • Ingår i: Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. - : Wiley. - 0960-7692. ; 20
  • Forskningsöversikt (refereegranskat)
  •  
22.
  • Kitlinski, Margareta, et al. (författare)
  • Skewed fetal gender distribution in prolonged pregnancy: a fallacy with consequences
  • 2003
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 21:3, s. 262-266
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective Skewed gender distribution and falsely assigned gestational age lead to unnecessary or late obstetric intervention in prolonged pregnancy. The aim of this study was to examine the consequences of a fetal gender-dependent systematic 1.5-day dating error at ultrasound fetometry. Material and methods A total of 82484 singleton deliveries greater than or equal to 37 weeks at 11 hospitals in southern Sweden from 1995 to 2000 were included. Frequencies of labor induction and Apgar scores < 7 at 5 min were compared with regard to fetal gender, both before and after correction of gestational age by adding 0.75 days to female-fetus pregnancies and subtracting 0.75 days from male-fetus pregnancies. Results The uncorrected odds ratio for having a male baby at greater than or equal to 42 weeks was 1.41 (95% confidence interval, 1.33-1.49). After adjusting gestational age by +/- 0.75 days, the odds ratio reduced to 0.90 (95% confidence interval, 0.84-0.95). The risk for labor induction was significantly above unity in male-fetus pregnancies delivered after 41 weeks when gestational age was corrected for fetal gender, while the risk for female fetuses having a low Apgar score was not significantly increased compared to male fetuses (P = 0.087). Conclusion Skewed gender distribution in prolonged pregnancy results in a higher rate of labor induction in pregnancies with male fetuses at greater than or equal to 41 weeks, and the risk for newborn females having a low Apgar score in prolonged pregnancy is not significantly increased compared to boys. Copyright (C) 2003 ISUOG. Published by John Wiley Sons, Ltd.
  •  
23.
  •  
24.
  • Källén, Karin (författare)
  • Mid-trimester ultrasound prediction of gestational age: advantages and systematic errors
  • 2002
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 20:6, s. 558-563
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To detect possible sources of bias in ultrasound prediction of gestational age. Subjects and Methods Using the Swedish Medical Birth Registry, 571 617 women were identified who were delivered between 1990 and 1997 and who had obtainable information on last menstrual period and expected date of delivery according to ultrasound. Results Male fetuses were more likely than females to be judged older than the last menstrual period date suggested at early fetometry. The estimated magnitude of the systematic error by infant gender corresponded to 1.5 days. Similarly, the fetuses of young women, multiparous women, smokers and women with low educational level were at increased risk of being smaller than expected at ultrasound examination in early pregnancy. A strong association was seen between adjustments of expected date of delivery -7 days or more and small-for-gestational age according to ultrasound at birth. Compared to singleton pregnancies, twin pregnancies were more likely to be judged more progressed at ultrasound fetometry than the last menstrual period date suggested. Conclusions Compared to last menstrual period estimates, routine ultrasound measurements to predict date of delivery are comparatively reliable but systematic errors are inherent in the method. The erroneous adjusted dates may be due to incorrect measurements or systematic bias (e.g. gender), but they are also likely to reflect early growth restriction (e.g. in the case of maternal smoking and small-for-gestational age). Further studies are needed to investigate whether the systematic errors in ultrasound prediction of gestational age could lead to suboptimal obstetric management in adjusted pregnancies.
  •  
25.
  •  
26.
  •  
27.
  •  
28.
  • Saltvedt, S, et al. (författare)
  • Ultrasound dating at 12-14 or 15-20 weeks of gestation? A prospective cross-validation of established dating formulae in a population of in-vitro fertilized pregnancies randomized to early or late dating scan
  • 2004
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 24:1, s. 42-50
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To determine the accuracy of established ultrasound dating formulae when used at 12-14 and 15-20 gestational weeks. Methods A total of 363 singleton pregnancies conceived after in-vitro fertilization (IVF) and randomized to a dating scan at 12-14 or 15-20 gestational weeks were studied. 'True' gestational age was calculated on the basis of the day of oocyte retrieval and was compared to gestational age calculated on the basis of seven dating formulae including the fetal biparietal diameter (BPD) and three dating formulae including BPD and fetal femur length (FL). The mean of the differences between estimated and true gestational age (systematic measurement error) and their SD (random measurement error) were calculated for each formula. Results Three formulae showed systematic errors of less than -0.7 days at both early and late scanning. Two formulae overestimated gestational age at both early and late scanning by 5.7 and 3.1 vs. 2.3 and 2.8 days, respectively, while five formulae manifested very different systematic errors at early and late scanning. The formulae used for clinical management underestimated gestational age by a mean of 3 days when dating was performed at 12-14 weeks, and by a mean of 0.8 days when dating was done at 15-20 weeks. The random error was on average 1 day less when the scan was carried out early (2 vs. 3 days; P < 0.0005). Mean true gestational age at delivery in IVF pregnancies with spontaneous start of labor was 279 days (SD 12.9); excluding preterm deliveries it was 2 81 days (SD 8.1). Conclusions Ultrasound dating formulae originally intended for use in the middle of the second trimester do not necessarily perform well when used for dating earlier in gestation. The systematic and random error of any dating formula must be assessed for the gestational age interval in which the formula is intended to be used. Copyright (C) 2004 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
29.
  •  
30.
  • Starck-Söndergaard, Marianne, et al. (författare)
  • Results of endosonographic imaging of the anal sphincter 2-7 days after primary repair of third- or fourth-degree obstetric sphincter tears.
  • 2003
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 22:6, s. 609-615
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To describe the endosonographic image of the anal sphincter 2-7 days after delivery in women who had undergone a primary repair of an obstetric sphincter tear. Methods Forty-eight women who had suffered a third- or fourth-degree sphincter tear at delivery and had undergone primary sphincter repair were examined with endoanal sonography 2-7 days after delivery. A score from 0 to 16 was used to describe the extent of the endosonographic defects, a score of 0 indicating no defect and a score of 16 a defect > 180° involving the whole length and depth of the sphincter. Clinical information was retrieved from the delivery and operation records after the analysis of the ultrasound images and the classification of the sonographic defects had been completed. Results Clinically, 34 (71%) women had a partial third-degree tear, 11 (23%) had a total third-degree tear, and three (6%) had a fourth-degree tear. Forty-three (90%; 95% CI, 77-97%) women had sonographic defects, all hypoechoic. Twenty-three (54%) sonographic defects were confined to the proximal part of the anal canal and involved less than half of the length of the anal canal. Thirty (63%) defects were confined to the external sphincter. Five of nine women (56%) with an endosonographic sphincter defect score 8 had undergone primary sphincter repair by a doctor in training vs. 9 of 39 women (23%) with an endosonographic sphincter score < 8 (P = 0.05), despite the fact that 86% (12/14) of the tears sutured by doctors in training were clinically partial third-degree tears vs. 65% (22/34) of those sutured by specialists (P = 0.15). Five (15%) of 34 women with a clinical partial third-degree tear had an endosonographic sphincter score 8 vs. four (29%) of 14 with a clinical total third- or fourth-degree sphincter tear (P = 0.26). Conclusions Most women (90%) with a clinical third- or fourth-degree obstetric sphincter tear have endosonographic sphincter defects if they are examined 2-7 days after primary repair. The extent of the endosonographic defects seems to be determined mainly by the surgical experience of the doctor performing the repair, and not by the clinical degree of the tear.
  •  
31.
  •  
32.
  •  
33.
  •  
34.
  • Valentin, Lil (författare)
  • Comparison of Lerner score, Doppler ultrasound examination, and their combination for discrimination between benign and malignant adnexal masses
  • 2000
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 15:2, s. 143-147
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To determine whether the combined use of Lerner's morphologic score and color Doppler ultrasound examination results in better discrimination of benign and malignant adnexal masses than the use of Lerner's score alone or Doppler variables alone. DESIGN: One hundred and seventy-three consecutive women with a pelvic mass judged clinically to be of adnexal origin underwent preoperative ultrasound examination including color and spectral Doppler techniques. One hundred and forty-nine tumors were benign and 24 malignant. The sensitivity and false-positive rate with regard to malignancy were calculated for Lerner's score, six Doppler variables and combinations of Lerner's score and Doppler variables. Previously defined gray scale and Doppler criteria of malignancy were used and tested prospectively. The best method was defined as that detecting most malignancies with the lowest false-positive rate. RESULTS: Lerner's score had a sensitivity of 92% and a false-positive rate of 36%. The best Doppler variable--time-averaged maximum velocity--had similar diagnostic properties with a sensitivity of 100% and a false-positive rate of 41%. Combining Lerner's score with Doppler measurement of time-averaged maximum velocity--i.e. requiring both Lerner's score and time-averaged maximum velocity to indicate malignancy for a malignant diagnosis to be made--had a sensitivity of 92% and a false-positive rate of 19%. CONCLUSIONS: The combined use of Lerner's score and measurement of time-averaged maximum velocity is a better method for discrimination of benign and malignant adnexal masses than the use of Lerner's score alone or Doppler ultrasound examination alone. The clinical value of the combined method needs to be cross-validated prospectively in a new series of tumors.
  •  
35.
  •  
36.
  •  
37.
  • Valentin, Lil, et al. (författare)
  • Intraobserver reproducibility of Doppler measurements of uterine artery blood flow velocity in premenopausal women
  • 2001
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 17:5, s. 431-433
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To determine the intraobserver repeatability of Doppler measurements of uterine artery blood flow velocity and the contribution of various factors to within-subject variance. DESIGN: Seventeen healthy premenopausal women underwent vaginal Doppler ultrasound examination of the uterine artery by the same observer. Three measurements were taken at each of three sites: 1) the currently recommended sampling site; 2) the ascending branch of the uterine artery at a level between the lower and middle third of the corpus uteri; 3) 1.5 cm lateral to the recommended sampling site. Three measurements were taken at each site. For each measurement, three uniform consecutive cardiac cycles were analyzed. Peak systolic velocity, time-averaged maximum velocity, and pulsatility index were calculated. Each Doppler shift spectrum was analyzed twice. Thus, for each women, 18 measurement results per sampling site were obtained. Analysis of variance was used. RESULTS: The effect of sampling site on measurements of peak systolic velocity and time-averaged maximum velocity was non-significant, but pulsatility index values obtained at the distal sampling site were slightly higher than those obtained at the other sites (P = 0.01). Repetition accounted for most of the within-subject variance. Averaging the results of the three repeat measurements yielded increased intraclass correlation coefficients: 0.79-0.89 for peak systolic velocity, 0.80-0.92 for time-averaged maximum velocity and 0.86-0.93 for pulsatility index. CONCLUSION: As the effect of repetition on the results of Doppler measurements of uterine artery blood flow velocity is large, the average of several repeat measurements should be used to enhance measurement reproducibility. However, it is not worth doing more than one analysis of a Doppler shift spectrum, and it is not worth analyzing more than one cardiac cycle per spectrum.
  •  
38.
  • Valentin, Lil, et al. (författare)
  • The natural history of adnexal cysts incidentally detected at transvaginal ultrasound examination in postmenopausal women
  • 2002
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 20:2, s. 174-180
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To determine the natural history of adnexal cysts incidentally detected at transvaginal ultrasound examination and judged to be benign in postmenopausal women.METHODS: One hundred and thirty-four postmenopausal women referred for ultrasound examination and found to have an adnexal cyst judged to be benign and not causing any symptoms were followed with transvaginal ultrasound at 3, 6 and 12 months, and then every 12 months. The referring physician treated the patient at his/her own discretion.RESULTS: One hundred and sixty cysts were found, 121 (76%) being unilocular and 39 more complicated. Seventy-two cysts (45%) had a largest diameter of 3-19 mm and 88 (55%) had a largest diameter of 20-80 mm. Median follow-up time was 3 (range, 0.3-8) years. In twelve women (9%) the cysts were removed during follow-up, all their cysts (n = 14) being benign. The indication to operate was a change in cyst morphology or increased cyst size in five (4%) women. In 39 (29%) women, the cysts disappeared; in 18 (13%), new cysts developed; and, in 65 (49%), the number of cysts and their location remained unchanged. Regression of cysts was observed in 54% (33/61) of women < 60 years vs. in 8% (6/73) of those > or = 60 years (P = 0.0001). Ultrasound findings remained unchanged in 34% (21/61) of women < 60 years vs. in 77% (56/73) of those > or = 60 years (P = 0.0001).CONCLUSIONS: The results support conservative management of adnexal cysts incidentally detected at transvaginal ultrasound examination and judged to be benign in postmenopausal women. Whether such cysts need to be followed-up at all and, if they do, how often and for how long, remains an open question.
  •  
39.
  •  
40.
  • Westergaard, H.B., et al. (författare)
  • A critical appraisal of the use of umbilical artery Doppler ultrasound in high-risk pregnancies: use of meta-analyses in evidence-based obstetrics
  • 2001
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 17:6, s. 466-476
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To reanalyze randomized controlled trials on the use of umbilical artery Doppler velocimetry in high-risk pregnancies and determine which high-risk pregnancies benefit from the use of Doppler velocimetry, Methods Searching Medline, the Cochrane Library and Embase we found 13 randomized controlled trials on the use of Doppler velocimetry in high-risk pregnancies. Of these, six included pregnancies with strictly defined suspected intrauterine growth restriction and/or hypertensive disease of pregnancy ('well-defined studies;); the rest included a great variety of high-risk pregnancies (general risk studies'). The studies were analyzed with particular regard 50 the heterogeneity and to outcome. Audits of the perinatal deaths reported in the randomized controlled trials were performed by a panel of 32 international experts. Results The 'well-defined studies ' had a more uniform study design as compared to the 'general risk studies' and they showed a significant reduction in antenatal admissions (odds ratio, 0.56; 95% confidence interval, 0.43 - 0. 72), inductions of labor (0. 78; 0.63 -0. 96), elective deliveries (inductions of labor and elective Cesarean sections) (0. 73; 0.61-0.88) and Cesarean sections (0. 78; 0, 65 - 0. 94). By perinatal audit it was found that more perinatal deaths in the 'well-defined studies' were potentially avoidable by use of Doppler velocimetry (P < 0.0005) and the rate of avoidable perinatal deaths was higher among controls (50%) than cases (20%) in this group. Conclusion The randomized controlled trials on umbilical artery Doppler velocimetry show major differences regarding study design and technical and clinical issues and, therefore, they should not be pooled in a simple meta-analysis. By stratification it was found that only in pregnancies with suspected intrauterine growth restriction and/or hypertensive disease of pregnancy will the use of umbilical artery Doppler velocimetry reduce the number of perinatal deaths and unnecessary obstetric interventions.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-40 av 40

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy