SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1399 6576 OR L773:0001 5172 srt2:(1976-1979)"

Sökning: L773:1399 6576 OR L773:0001 5172 > (1976-1979)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ask, Per, 1950-, et al. (författare)
  • ECG Electrodes : A Study of Electrical and Mechanical Long-term Properties
  • 1979
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 23:2, s. 189-206
  • Tidskriftsartikel (refereegranskat)abstract
    • The long-term properties of commercially available ECG-electrodes were studied by investigating the parameters: polarization potential, electrical impedance, adhesion, and skin reactions during a period of 7 days. As expected, the most stable polarization potentials were obtained for Ag/AgCl electrodes. Certain simple disposable electrodes showed large polarization potential variations. The most stable electrode impedance was obtained for disposable electrodes with stable adhesion and equipped with an electrode cup or similar. Unchanged adhesion and mechanical properties during the test period were shown by the disposable electrodes with a large self-adhesive collar.
  •  
2.
  • Hedenstierna, G, et al. (författare)
  • Airway closure and distribution of inspired gas in the extremely obese, breathing spontaneously and during anaesthesia with intermittent positive pressure ventilation.
  • 1976
  • Ingår i: Acta Anaesthesiologica Scandinavica. - 0001-5172 .- 1399-6576. ; 20:4, s. 334-42
  • Tidskriftsartikel (refereegranskat)abstract
    • Airway closure (closing capacity, CC), FRC, total efficiency of ventilation (lung clearance index, LCI) and distribution of inspired gas (nitrogen washout declay percentage, NWOD) were determined by nitrogen washout techniques and arterial PO2and PCO2 measured by standard electrodes in 10 extremely obese subjects, prior to an during anaesthesia and artifical ventilation. CC was normal, but because of small FRC, airway closure occurred within a tidal breath in 9 out of 10 subjects during spontaneous breathing, when awake. PO2 was reduced, the hypoxaemia correlating to the magnitude of airway closure. LCI was normal, but NWOD was borderline. During anaesthesia, CC was unaltered by FRC was further reduced, so that in nine subjects sirway closure occurred above FRC and tidal volume together. A marked increase in relative hypoxaemia was recorded. LCI and NWOD rose, indicating less efficient and less even ventilation. It is concluded that airway closure reasonably explains the marked hypoxaemia in obese subjects during anaesthesia, and that it may also be the reason for the uneven distribution of inspired gas.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Ask, Per, 1950- (1)
Öberg, Åke (1)
Hedenstierna, G (1)
Ödman, S. (1)
Tenland, T. (1)
Skogh, M. (1)
visa fler...
Santesson, J (1)
Norlander, O (1)
visa färre...
Lärosäte
Uppsala universitet (1)
Linköpings universitet (1)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy