1.
  • Affatato, S., et al. (författare)
  • Larger diameter bearings reduce wear in metal-on-metal hip implants
  • 2007
  • Ingår i: Clinical Orthopaedics and Related Research. - : Ovid Technologies (Wolters Kluwer Health). - 0009-921X .- 1528-1132. ; :456, s. 153-158
  • Tidskriftsartikel (refereegranskat)abstract
    • Metal-on-metal hip arthroplasty has the longest clinical history of all total arthroplasties. We asked whether large diameter femoral heads would result in less wear than those with small diameters. We also asked if there is a threshold diameter that ensures good wear behavior. We tested three batches of cast high-carbon cobalt-chromium-molybdenum hip implants (28 mm, 36 min, and 54 min diameters) in a hip simulator for 5 million cycles. We used bovine serum as lubricant and weighed the samples at regular intervals during testing. The 28-mm configuration had almost twice the wear of the 54-mm configuration, but we observed no difference between the 36-mm and the 54-mm configurations. The similarity in the wear performances of the larger configurations supports the presence of a threshold diameter that ensures good wear behavior.
  •  
2.
  • Benoit, Daniel L, et al. (författare)
  • In vivo knee kinematics during gait reveals new rotation profiles and smaller translations
  • 2007
  • Ingår i: Clinical Orthopaedics and Related Research. - : Lippincott Williams & Wilkins. - 0009-921X .- 1528-1132. ; 454, s. 81-88
  • Tidskriftsartikel (refereegranskat)abstract
    • In order to identify abnormal or pathological motions associated with clinically relevant questions such as injury mechanisms or factors leading to joint degeneration, it is essential to determine the range of normal tibiofemoral motion of the healthy knee. In this study we measured in vivo 3D tibiofemoral motion of the knee during gait and characterized the nonsagittal plane rotations and translations in a group of six healthy young adults. The subjects were instrumented with markers placed on intracortical pins inserted into the tibia and femur as well as marker clusters placed on the skin of the thigh and shank. The secondary rotations and translation excursions of the knee were much smaller than those derived from skin markers and previously described in the literature. Also, for a given knee flexion angle, multiple combinations of transverse and frontal plane knee translation or rotation positions were found. This represents normal knee joint motions and ensemble averaging of gait data may mask this important subject-specific information.
  •  
3.
  • Bottner, F, et al. (författare)
  • Implant migration after early weightbearing in cementless hip replacement
  • 2005
  • Ingår i: Clinical Orthopaedics and Related Research. - 0009-921X .- 1528-1132. ; :436, s. 132-137
  • Tidskriftsartikel (refereegranskat)abstract
    • Twenty-nine patients (five women and 24 men) with an average age of 47 years (range, 24-59 years) had 37 total hip arthroplasties using a hydroxyapatite-coated double-wedge press-fit femoral component. All patients had a Type A bone quality. Patients were either mobilized with weightbearing as tolerated or toe-touch weightbearing for 6 weeks postoperatively. After 6 weeks all patients were advanced to weightbearing as tolerated. Radiostereometric analysis radiographs were taken at 3 days, 6 weeks, and 6 months postoperatively to measure migration of the femoral component. Radiostereometric analysis revealed no difference in stem migration between the two groups as defined by maximal total point migration. There was a difference in the vertical (proximal-distal) migration within the first 6 weeks between groups (0.81 mm versus 0.13 mm), but not afterwards (0.17 mm versus 0.18 mm). Continuous migration after 6 weeks was observed in three patients from each group. There was no loosening in either group within a 2-year followup. Weightbearing as tolerated is recommended for young patients with excellent bone quality after cementless total hip arthroplasty with a double-wedge press-fit femoral component. Level of Evidence: Diagnostic study, Level I (testing of previously developed diagnostic criteria in series of consecutive patients-with previously applied reference gold standard). See the Guidelines for Authors for a complete description of levels of evidence.
  •  
4.
  • Eliasson, Pernilla, et al. (författare)
  • Mechanical load and BMP signaling during tendon repair : A role for follistatin?
  • 2008
  • Ingår i: Clinical Orthopaedics and Related Research. - : Ovid Technologies (Wolters Kluwer Health). - 0009-921X .- 1528-1132. ; 466:7, s. 1592-1597
  • Tidskriftsartikel (refereegranskat)abstract
    • Healing of the rat Achilles tendon is sensitive to mechanical loading, and the callus strength is reduced by 3/4 after 14 days, if loading is prevented. Exogenous GDFs stimulate tendon healing. This response is influenced by loading: without loading, cartilage and bone formation is initiated. This implies BMP signaling is crucial during tendon healing and influenced by mechanical loading. We therefore asked if mechanical loading influences the gene expression of the BMP signaling system in intact and healing tendons, and how the BMP signaling system changes during healing. The genes were four BMPs (OP-1/BMP-7, GDF-5/CDMP-1/BMP-14, GDF-6/CDMP2/BMP-13, and GDF-7/CDMP-3/BMP-12), two receptors (BMPR1b and BMPR2), and the antagonists follistatin and noggin. The Achilles tendon was transected in rats and left to heal. Half of the rats had one Achilles tendon unloaded by injection of Botox in the calf muscles. Ten tendons were analyzed before transection and for each of four time points. All genes except noggin were expressed at all points, but followed different patterns during healing. Loading strongly decreased the expression of follistatin, which could lead to increased signaling. The BMP system appears involved in tendon maintenance and healing, and may respond to mechanical loading.
  •  
5.
  •  
6.
  • Hannink, G, et al. (författare)
  • High doses of OP-1 inhibit fibrous tissue ingrowth in impaction grafting
  • 2006
  • Ingår i: Clinical Orthopaedics and Related Research. - : Ovid Technologies (Wolters Kluwer Health). - 0009-921X .- 1528-1132. ; :452, s. 250-259
  • Tidskriftsartikel (refereegranskat)abstract
    • A major concern in using growth factors in impaction grafting is the potential stimulation of the osteoclastic lineage. A solution would be using an osteoconductive material resistant to resorption and providing initial stability after reconstruction. Growth factors may promote bone formation in combination with such graft materials. We determined whether OP-1 would promote the incorporation of impacted morselized allografts and tricalcium phosphate/hydroxyapatite (TCP/HA) into host bone, whether bone formation would be preceded by an initial process of accelerated resorption, and whether the response to OP-1 remodeling/incorporation would be dose-related. We performed two bone chamber studies in goats to ascertain the early effects of OP-1 dose on resorption and incorporation of impacted morselized allografts and TCP/HA. After 4 weeks, the incorporation process of impacted morselized allografts and TCP/HA was not promoted by OP-1. We observed no signs of accelerated resorption preceding bone formation. An increase in OP-1 dose resulted in an inhibition of fibrous tissue formation but OP-1 did not promote bone formation. Early failures in impaction grafting, using mixes with OP-1, might be explained by the lack of fibrous tissue ingrowth and not by increased resorption and remodeling. © 2006 Lippincott Williams & Wilkins, Inc.
  •  
7.
  • Henricson, Anders, 1944-, et al. (författare)
  • Mobile bearings do not improve fixation in cemented total knee arthroplasty
  • 2006
  • Ingår i: Clinical Orthopaedics and Related Research. - : Ovid Technologies (Wolters Kluwer Health). - 0009-921X .- 1528-1132. ; 448, s. 114-121
  • Tidskriftsartikel (refereegranskat)abstract
    • Mobile bearings were introduced to improve wear and knee kinematics. By uncoupling the forces generated at the articulation from the implant-bone interface this would, theoretically, also improve the fixation of the implant to bone. We did this study to evaluate whether mobile bearings improve the fixation of the tibial component to bone. Fifty-two consecutive knees in 47 patients (average age, 72 years; range, 62-84 years) with primary osteoarthrosis were randomized into two groups to receive a cemented total knee arthroplasty with either a fixed-bearing or mobile-bearing tibial component. The quality of fixation was analyzed with radiostereometric analysis for up to 2 years. Mobile bearings did not improve fixation. Both magnitudes and directions of component rotations were similar, and the number of implants with continuous migration was almost identical. Both implant types had a combination of subsidence and lift-off, but where the mobile bearing implants displayed more of subsidence, the fixed bearing knees showed more lift-off. It might be that the somewhat stiffer cobalt-chromium baseplate or the different joint conformity used in the mobile-bearing knees counteracts any potential effects of the mobile bearing.
  •  
8.
  • Nilsson, Kjell G, 1953-, et al. (författare)
  • Uncemented HA-coated implant is the optimum for the TKA in the young patient
  • 2006
  • Ingår i: Clinical Orthopaedics and Related Research. - : Ovid Technologies (Wolters Kluwer Health). - 0009-921X .- 1528-1132. ; 448, s. 129-139
  • Tidskriftsartikel (refereegranskat)abstract
    • Fixation of the tibial component in total knee arthroplasty in younger patients remains controversial. We evaluate the results of three different types of fixation of the Profix total knee arthroplasty in a randomized controlled trial of 97 consecutive knees (85 patients) with osteoarthrosis or inflammatory arthritis with 2-year followup of all patients. We randomized patients to three different types of fixation of the tibial component: cemented, uncemented (HA coated) with screws, or uncemented (HA coated) without screws. We performed clinical evaluations and radiostereometric analysis at 6 weeks, and 3, 6, 12 and 24 months postoperatively. The knees in the uncemented groups migrated more than those in the cemented group during the first 3 months, but at 2 years we observed no differences. The uncemented implants displayed all migration within the first 3 months. The cemented implants did not stabilize but had continuously increasing migration during the followup. Cementless implants without screws did not migrate more than implants with screws and displayed similar pattern of migration, indicating screws do not improve fixation. Uncemented fixation using hydroxyapatite-coated implants without screws seems to be the best solution for the younger patient.
  •  
9.
  • Rahme, Hans, et al. (författare)
  • Cement and press-fit humeral stem fixation provides similar results in rheumatoid patients
  • 2006
  • Ingår i: Clinical Orthopaedics and Related Research. - : Ovid Technologies (Wolters Kluwer Health). - 0009-921X .- 1528-1132. ; :448, s. 28-32
  • Tidskriftsartikel (refereegranskat)abstract
    • It is unclear whether humeral stems should be fixed with or without cement. We question whether press-fit fixation would provide similar results to cemented stem fixation. We prospectively randomized 26 shoulders in 24 patients with rheumatoid arthritis (20 women, 4 men) to have either a cemented or press-fit stem. In the press-fit group, stems were matched to the medullary canal, while lavage, pressurizing and distal plugging were used in the cemented group. We followed patients with conventional radiographs and radiostereometric analysis (RSA) at 5 to 7 days, 4 months, 1 year, and 2 years after surgery. One patient died from unrelated causes before the 1-year followup, while the remaining patients were followed according to the protocol. All but two patients were very satisfied or satisfied at 2 years. No stem was radiographically loose. There was no difference in micromotion between groups. The average rotation for all axes was less than 0.25° for both groups and the average translation was less than 0.32 mm for all three axes including subsidence, which was less than 0.1 mm for the uncemented stems. We concluded at 2 years these stems provided similar fixation in rheumatoid shoulders.
  •  
10.
  • Röhrl, Stephan, et al. (författare)
  • Migration pattern of a short femoral neck preserving stem
  • 2006
  • Ingår i: Clinical Orthopaedics and Related Research. - : Wolters Kluwer. - 0009-921X .- 1528-1132. ; 448:July, s. 73-78
  • Tidskriftsartikel (refereegranskat)abstract
    • AB The CFP stem represents a short collared neck-retaining stem with very proximal metaphyseal anchoring along the calcar combined with up-to-date metallurgy. Despite theoretical advantages, the stability and clinical outcome are unknown. We prospectively measured the migration pattern of this new stem and cup. Twenty-six patients (26 hips) with a mean age of 54 years (range, 40-66 years) underwent THA and were followed for 2 years with radiostereometry, radiographs, and clinical scores. The stem showed some early retroversion (mean, SEM 0.6[degrees], 0.3), but stabilized before 1 year. Subsidence (0.05 mm, 0.06) and varus-valgus tilting (0.03[degrees], 0.01) were low. We observed no bone loss in the calcar region. Factors related to patients, implant design, and implantation did not predict migration patterns. The two-dimensional wear of the ceramic/conventional articulation was 0.09 mm at 2-24 months. The low migration of this short neck preserving stem suggests a favorable long-term outcome but longer followup is needed to substantiate this prediction. This design might become an alternative to standard stems and hip resurfacing. Level of Evidence: Therapeutic Level IV. See The Guidelines for Authors for a complete description of levels of evidence.
  •  
11.
  • Ström, Håkan, et al. (författare)
  • Early migration pattern of the uncemented CLS stem in total hip arthroplasties
  • 2007
  • Ingår i: Clinical Orthopaedics and Related Research. - : Ovid Technologies (Wolters Kluwer Health). - 0009-921X .- 1528-1132. ; :454, s. 127-132
  • Tidskriftsartikel (refereegranskat)abstract
    • We performed this investigation to determine the possible migration starting immediately after surgery and the effect of different weightbearing regimens on the migration pattern of an uncemented hip stem (CLS). Stem migration was determined with radiostereometry analysis with baseline when the patients still were anesthetized. Subsequent examinations were done up to 1 year. Twenty-nine patients (mean age, 55 years; range, 26-63 years) were randomized to either unrestricted weightbearing combined with intensive physiotherapy from the first day after surgery or to partial weightbearing and a conservative training regimen for the first 3 months after surgery. At 1 week, subsidence was -0.03 mm in the unrestricted weightbearing group and 0.01 mm in the partial weightbearing group. At 1 year, subsidence was 1.01 mm in the unrestricted weightbearing group and 0.51 mm in the partial weightbearing group. One patient in the unrestricted weightbearing group had revision surgery because of aseptic loosening at 1.5 years after surgery. The CLS stem did not have any migration from the end the surgery until 1 week, but there was small migration from 1 week to 3 months after which the stem remained stable. The degree of early weightbearing did not affect the migration pattern.
  •  
12.
  • Vasara, Anna I, et al. (författare)
  • Persisting high levels of synovial fluid markers after cartilage repair: a pilot study.
  • 2009
  • Ingår i: Clinical orthopaedics and related research. - : Ovid Technologies (Wolters Kluwer Health). - 1528-1132 .- 0009-921X. ; 467:1, s. 267-72
  • Tidskriftsartikel (refereegranskat)abstract
    • Local attempts to repair a cartilage lesion could cause increased levels of anabolic and catabolic factors in the synovial fluid. After repair with regenerated cartilage, the homeostasis of the cartilage ideally would return to normal. In this pilot study, we first hypothesized levels of synovial fluid markers would be higher in patients with cartilage lesions than in patients with no cartilage lesions, and then we hypothesized the levels of synovial fluid markers would decrease after cartilage repair. We collected synovial fluid samples from 10 patients before autologous chondrocyte transplantation of the knee. One year later, a second set of samples was collected and arthroscopic evaluation of the repair site was performed. Fifteen patients undergoing knee arthroscopy for various symptoms but with no apparent cartilage lesions served as control subjects. We measured synovial fluid matrix metalloproteinase-3 (MMP-3) and insulinlike growth factor-I (IGF-I) concentrations with specific activity and enzyme-linked immunosorbent assays, respectively. The levels of MMP-3 and IGF-I were higher in patients having cartilage lesions than in control subjects with no cartilage lesions. One year after cartilage repair, the lesions were filled with repair tissue, but the levels of MMP-3 and IGF-I remained elevated, indicating either graft remodeling or early degeneration. Level of Evidence: Level III, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.
  •  
13.
  • Zhou, Zong-ke, et al. (författare)
  • No Increased Migration in Cups with Ceramic-on-Ceramic Bearing : An RSA Study
  • 2006
  • Ingår i: Clinical Orthopaedics and Related Research. - : Ovid Technologies (Wolters Kluwer Health). - 0009-921X .- 1528-1132. ; :448, s. 39-45
  • Tidskriftsartikel (refereegranskat)abstract
    • Ceramic-on-ceramic hip replacements might stress the bone interface more than a metal-polyethylene because of material stiffness, microseparation, and sensitivity to impingement. To ascertain whether this potentially increased stress caused an increased cup migration we compared a ceramic-on-ceramic with a metal-on-polyethylene implant for cup migration. Sixty one patients (61 hips) undergoing THA for osteoarthritis were randomized to ceramic on ceramic (Ce/Ce) or cobalt-chromium on cross-linked polyethylene bearings (PE) in the same uncemented cup shell. Migrationwas followed with RSA. At 2 years we observed similar mean cup translations in the 3 directions (0.07–0.40 mm vs. 0.05–0.31 mm, Ce/Ce vs. PE), as well as similar rotations around the 3 axes (0.31–0.92° vs. 0.57–1.40°). WOMAC and SF-36 scores were also similar and no radiolucent lines or osteolysis found. The large migration seen in some cups in both implant groups will require close monitoring to ascertain the reasons. Mean proximal wear of the polyethylene liners measured 0.016 mm between 2 and 24 months. Our data suggest there is no increased cup migration in the ceramic-on-ceramic implant compared with the metal-on-polyethylene, and they seem an equally safe choice. However, the low wear measured with the more versatile and less expensive cross-linked polyethylene makes it a strong contender. Levels of Evidence: Therapeutic Level I. See the Guidelinesfor Authors for a complete description of levels of evidence.
  •  