SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1619 7089 OR L773:1619 7070 srt2:(2000-2004)"

Sökning: L773:1619 7089 OR L773:1619 7070 > (2000-2004)

  • Resultat 1-50 av 56
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Benjegård, S A, et al. (författare)
  • Intraoperative tumour detection using 111In-DTPA-D-Phe1-octreotide and a scintillation detector.
  • 2001
  • Ingår i: European journal of nuclear medicine. - : Springer Science and Business Media LLC. - 0340-6997 .- 1619-7070 .- 1619-7089. ; 28:10, s. 1456-62
  • Tidskriftsartikel (refereegranskat)abstract
    • Intraoperative tumour detection has been used in many applications. The examined tumour forms have varied and different detector systems and radiopharmaceuticals have also been used. The aim of this study was to evaluate and compare the ability of an NaI(T1) scintillation detector to detect primary tumours and metastases in patients with different endocrine tumour types (e.g. carcinoid tumours, endocrine pancreatic tumours and thyroid tumours) and in patients with breast carcinoma or benign thyroid lesions, on the basis of their somatostatin receptor expression after i.v. injection of 111In-DTPA-D-Phe1-octreotide. Thirty patients were injected with 111In-DTPA-D-Phe1-octreotide intravenously. Scintigraphic images were taken 1 day after injection of the radiopharmaceutical, and surgery was performed 1-7 days post injection. An NaI(T1) scintillation detector was used for intraoperative tumour detection. Tissue samples were collected during surgery for determination of 111In activity concentration and histopathological examination. The scintigraphic images were positive in 29 out of 30 patients. Intraoperative tumour detection was successful in 43 of 66 collected biopsies: 10 out of 11 for carcinoid tumours, 7 out of 10 for medullary thyroid carcinoma (MTC) and 14 out of 22 for breast cancer. On the basis of our findings we conclude that intraoperative tumour detection with 111In-DTPA-D-Phe1-octreotide using this NaI(T1) detector can be successful especially for carcinoid tumours and endocrine pancreatic tumours, due to the relatively high activity concentrations in these tumour types, but is less successful in other forms of thyroid cancer, including MTC, and breast cancer. For successful intraoperative detection, the detector characteristics are also very important, and further improvement of the detector systems is required to increase the sensitivity and specificity.
  •  
2.
  •  
3.
  •  
4.
  • Elgh, Eva, et al. (författare)
  • Memory functions and rCBF (99m)Tc-HMPAO SPET : developing diagnostics in Alzheimer's disease
  • 2002
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 29:9, s. 1140-1148
  • Tidskriftsartikel (refereegranskat)abstract
    • Alzheimer's disease (AD) is a primary degenerative disease of the brain. The prevalence increases with age, with devastating consequences for the individual and society. The aim of this study was to evaluate whether patients with early AD show an altered regional cerebral blood flow (rCBF) compared with control persons. Furthermore, we aimed to investigate the correlation between rCBF in sublobar volumes of the brain and performance on memory tests. Memory tests were chosen to evaluate episodic and semantic memory. Fourteen patients (aged 75.2+/-8.8 years) with early AD and 15 control persons (aged 71.4+/-3.2 years) were included. rCBF measurements with single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO) were performed. The rCBF (99m)Tc-HMPAO SPET images were spatially transformed to fit a brain atlas and normalised for differences in rCBF (Computerised Brain Atlas software). Cortical and subcortical volumes of interest (VOIs) were analysed and compared. Compared with the controls, AD patients showed a significantly lower rCBF ratio in temporoparietal regions, including the left hippocampus. The diagnostic sensitivity and specificity for AD were high in temporoparietal regions. AD patients had significantly reduced performance on semantic and, in particular, episodic memory tests compared with age-matched normative data, and their performance on several episodic tests correlated with rCBF ratios in parietal and temporal regions, including the left hippocampus. The correlation between rCBF ratio and level of episodic memory performance suggests that abnormalities in rCBF pattern underlie impaired episodic memory functioning in AD.
  •  
5.
  •  
6.
  •  
7.
  • Eriksson, David, et al. (författare)
  • Combined low dose radio- and radioimmunotherapy of experimental HeLa Hep 2 tumours.
  • 2003
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 30:6, s. 895-906
  • Tidskriftsartikel (refereegranskat)abstract
    • Radiation therapy of malignant tumours can be delivered by external beam radiation (RT) or radioimmunotherapy (RIT), using nuclides attached to monoclonal antibodies (mAbs). These treatment modalities have now been combined in order to investigate putative therapeutic advantages and elucidate the biological responses involved. Nude mice were transplanted subcutaneously on the back with human HeLa Hep2 tumour cells. RT (3x5 Gy) and/or 100 microg (131)I-labelled mAb H7, against placental alkaline phosphatase, or (131)I-labelled mAb TS1, against cytokeratin, was administered separately or in combination (specific activity of 120-200 MBq/mg antibody). Significant tumour growth retardation was observed both with RT alone and with RIT alone. Combining these regimens enhanced the therapeutic effects further, and a significant reduction in tumour volume could be demonstrated. The tumours were subjected to extensive histochemical and immunohistochemical investigations in order to elucidate changes in biology and histology within them. The following stainings were used: haematoxylin-eosin (morphology), Ki67 (proliferation), M30 (apoptosis), TUNEL (apoptosis) and endoglin (vascularisation). Tumours in the control group grew fast, with an average tumour doubling time of 9 days. These tumours contained large viable tumour cell masses displaying vast proliferation zones of Ki67-positive tumour cells, as well as necrotic regions and small amounts of connective tissue. Apoptotic cells could be identified both with M30 and TUNEL staining. When RT was applied, the growth rate was significantly reduced (doubling time 19 days) and typical alterations in morphology were seen, with a relative increase in connective tissue and a decrease in necrotic regions. Apoptotic cells were identified and a decrease in cell density was also observed. When RIT alone was applied, the growth parameters indicated a longer lasting growth reduction, especially when TS1 was used separately or in combination with H7. The histological appearances of these tumours were somewhat different from the RT-treated tumours, with a larger portion of intratumoural cysts. These tumours also presented a reduced tumour cell density. Dramatic effects were observed when RT was combined with RIT, with a pronounced growth reduction seen in all combination treatment groups. Pronounced tumour volume reduction was also evident in both the RT + RIT ((131)I-TS1) group and RT + RIT ((131)I-TS1/(131)I-H7) group, and in some animals no tumour remained at all. The morphology of the tumour remnants at day 22 was chaotic with a drastically changed histology, with presence of abundant cysts, low fractions of Ki67-positive cells, reduction in cell density, increased amounts of connective tissue and a decrease in necrotic regions. Again, apoptotic cells could be identified, scattered throughout the viable regions. Combining RT and RIT seems to generate an efficient treatment with convincing and long-lasting tumour growth inhibition, which is reflected in a highly aberrant histology within the tumour. Results obtained in this study indicate that both necrosis and apoptosis may be involved in the process leading to this efficient therapy of epithelially derived tumours.
  •  
8.
  • Evander, Eva, et al. (författare)
  • Role of ventilation scintigraphy in diagnosis of acute pulmonary embolism: an evaluation using artificial neural networks.
  • 2003
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 30:7, s. 961-965
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to assess the value of the ventilation study in the diagnosis of acute pulmonary embolism using a new automated method. Either perfusion scintigrams alone or two different combinations of ventilation/perfusion scintigrams were used as the only source of information regarding pulmonary embolism. A completely automated method based on computerised image processing and artificial neural networks was used for the interpretation. Three artificial neural networks were trained for the diagnosis of pulmonary embolism. Each network was trained with 18 automatically obtained features. Three different sets of features originating from three sets of scintigrams were used. One network was trained using features obtained from each set of perfusion scintigrams, including six projections. The second network was trained using features from each set of (joint) ventilation and perfusion studies in six projections. A third network was trained using features from the perfusion study in six projections combined with a single ventilation image from the posterior view. A total of 1,087 scintigrams from patients with suspected pulmonary embolism were used for network training. The test group consisted of 102 patients who had undergone both scintigraphy and pulmonary angiography. Performances in the test group were measured as area under the receiver operation characteristic curve. The performance of the neural network in interpreting perfusion scintigrams alone was 0.79 (95% confidence limits 0.71–0.86). When one ventilation image (posterior view) was added to the perfusion study, the performance was 0.84 (0.77–0.90). This increase was statistically significant (P=0.022). The performance increased to 0.87 (0.81–0.93) when all perfusion and ventilation images were used, and the increase in performance from 0.79 to 0.87 was also statistically significant (P=0.016). The automated method presented here for the interpretation of lung scintigrams shows a significant increase in performance when one or all ventilation images are added to the six perfusion images. Thus, the ventilation study has a significant role in the diagnosis of acute lung embolism.
  •  
9.
  •  
10.
  •  
11.
  •  
12.
  •  
13.
  •  
14.
  •  
15.
  •  
16.
  •  
17.
  •  
18.
  • Khan, Tanweera Shaheena, et al. (författare)
  • 11C-metomidate PET imaging of adrenocortical cancer
  • 2003
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - 1619-7070 .- 1619-7089. ; 30:3, s. 403-410
  • Tidskriftsartikel (refereegranskat)
  •  
19.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  •  
25.
  •  
26.
  •  
27.
  • Ribom, Dan, et al. (författare)
  • Potential significance of 11C-methionine PET as a marker for the radiosensitivity of low-grade gliomas
  • 2002
  • Ingår i: European Journal of Nuclear Medicine. - : Springer Science and Business Media LLC. - 0340-6997 .- 1432-105X .- 1619-7070 .- 1619-7089. ; 29:5, s. 632-640
  • Tidskriftsartikel (refereegranskat)abstract
    • The role for radiotherapy in patients with low-grade gliomas remains controversial. Two large prospective studies have failed to demonstrate a radiotherapeutic dose-response effect, and EORTC trial 22845 found no difference in survival between patients receiving adjuvant radiotherapy and those who received radiotherapy at tumour progression. The aim of this retrospective study was to analyse the patterns of carbon-11 methionine (MET) uptake on positron emission tomography (PET) in tumours treated with immediate radiotherapy and in those treated with delayed radiotherapy at the time of tumour progression. The 21 adult patients studied had histologically confirmed low-grade gliomas and had undergone a pre-treatment PET scan and a follow-up PET scan at the time of progression. Eleven of the patients had undergone initial radiotherapy a median of 5 weeks after the surgical procedure. The median time to progression was 3.5 years for this group, compared with 1.6 years for the group with delayed radiotherapy ( P=0.06). At the time of progression, non-irradiated tumours had a significantly higher MET uptake ( P=0.02) and a larger uptake volume ( P=0.008) compared with baseline, whereas irradiated tumours showed no statistically significant change. We observed a correlation between high pre-treatment uptake of MET and reduction in MET uptake in response to radiotherapy ( P=0.008). All irradiated tumours recurred within the radiation field. In conclusion, our results demonstrate signs of a residual radiation effect at the time of tumour progression in low-grade gliomas with high pre-treatment uptake of MET. Pre-treatment methionine uptake may be a marker for the radiosensitivity of low-grade gliomas.
  •  
28.
  •  
29.
  •  
30.
  •  
31.
  • Sundberg, Åsa Liljegren, et al. (författare)
  • Combined effect of gefitinib ('Iressa', ZD1839) and targeted radiotherapy with 211At-EGF
  • 2003
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 30:10, s. 1348-56
  • Tidskriftsartikel (refereegranskat)abstract
    • The EGFR-TKI (epidermal growth factor receptor tyrosine kinase inhibitor) gefitinib ['Iressa' (trademark of the AstraZeneca group of companies), ZD1839] increases the cellular uptake of radiolabelled epidermal growth factor (EGF). We investigated gefitinib treatment combined with astatine-211 EGF targeting in vitro using two cell lines expressing high levels of EGFR: A431 (sensitive to gefitinib) and U343MGaCl2:1 (resistant to gefitinib). In both cell lines, the uptake of 211At-EGF was markedly increased by concomitant treatment with gefitinib. Survival was investigated using both a clonogenic survival assay and a cell growth assay. Combined gefitinib and 211At-EGF treatment reduced the survival of U343 cells 3.5-fold compared with 211At-EGF alone. In A431 cells, 211At-EGF treatment resulted in very low survival, but combined treatment with gefitinib increased the survival by about 20-fold. These results indicate that combined treatment with gefitinib might increase the effect of ligand-mediated radionuclide therapy in gefitinib-resistant tumours and decrease the effect of such therapy in gefitinib-sensitive tumours.
  •  
32.
  • Sundberg, Åsa Liljegren, et al. (författare)
  • Treatment of cultured glioma cells with EGFR-TKI gefitinib (‘Iressa’, ZD1839) increases the uptake of astatinated EGF despite absence of gefitinib-mediated growth inhibition
  • 2003
  • Ingår i: European Journal of Nuclear Medicine. - : Springer Science and Business Media LLC. - 0340-6997 .- 1432-105X .- 1619-7070 .- 1619-7089. ; 30:5, s. 727-9
  • Tidskriftsartikel (refereegranskat)abstract
    • The EGFR-TKI (epidermal growth factor receptor tyrosine kinase inhibitor) gefitinib ("Iressa", ZD1839), a reversible growth inhibitor of EGFR-expressing tumour cells, has been shown to enhance the antitumour effect of ionising radiation, and also to increase the uptake of radioiodinated EGF. Thus, combination of gefitinib treatment and radionuclide targeting is an interesting option for therapy of brain tumours that are difficult to treat with conventional methods. The aim of this study was to evaluate how pre-treatment with gefitinib affects binding of astatinated EGF ((211)At-EGF) to cultured glioma U343 cells, which express high levels of EGFR. The growth of U343 cells in the presence of gefitinib was investigated, and it was found that gefitinib does not significantly inhibit the growth of these cells. Nevertheless, the uptake of (211)At-EGF in U343 cells was markedly increased (up to 3.5 times) in cells pre-treated with gefitinib (1 microM). This indicates that a combination of gefitinib treatment and radionuclide targeting to EGFR might be a useful therapeutic modality, even for patients who do not respond to treatment with gefitinib alone.
  •  
33.
  • Svensson, Annmarie, et al. (författare)
  • Quantification of myocardial perfusion defects using three different software packages.
  • 2004
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 31:2, s. 229-232
  • Tidskriftsartikel (refereegranskat)abstract
    • Software packages are widely used for quantification of myocardial perfusion defects. The quantification is used to assist the physician in his/her interpretation of the study. The purpose of this study was to compare the quantification of reversible perfusion defects by three different commercially available software packages. We included 50 consecutive patients who underwent myocardial perfusion single-photon emission tomography (SPET) with a 2-day technetium-99m tetrofosmin protocol. Two experienced technologists processed the studies using the following three software packages: Cedars Quantitative Perfusion SPECT, Emory Cardiac Toolbox and 4D-MSPECT. The same sets of short axis slices were used as input to all three software packages. Myocardial uptake was scored in 20 segments for both the rest and the stress studies. The summed difference score (SDS) was calculated for each patient and the SDS values were classified into: normal (<4), mildly abnormal (4–8), moderately abnormal (9–13), and severely abnormal (>13). All three software packages were in agreement that 21 patients had a normal SDS, four patients had a mildly abnormal SDS and one patient had a severely abnormal SDS. In the remaining 24 patients (48%) there was disagreement between the software packages regarding SDS classification. A difference in classification of more than one step between the highest and lowest scores, for example from normal to moderately abnormal or from mildly to severely abnormal, was found in six of these 24 patients. Widely used software packages commonly differ in their quantification of myocardial perfusion defects. The interpreting physician should be aware of these differences when using scoring systems.
  •  
34.
  •  
35.
  • Xu, Jiahua, et al. (författare)
  • Quantitative analysis of inhomogeneity in ventilation SPET
  • 2001
  • Ingår i: European Journal of Nuclear Medicine. - : Springer. - 0340-6997 .- 1432-105X .- 1619-7070 .- 1619-7089. ; 28:12, s. 1795-1800
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to evaluate a method for quantification of inhomogeneity in ventilation single-photon emission tomography (SPET). Nine emphysematous patients, nine life-long non-smokers and nine smokers were included in the study. The SPET investigation was performed after 50 MBq (99m)Tc-Technegas had been inhaled by each subject in the supine position. A single-head gamma camera, equipped with a general-purpose parallel-hole collimator using 64 projections (20 s each) over 360 degrees, was used. Data were acquired in 128x128 matrices. Attenuation correction was applied based upon computed tomography (CT) density maps. Lung regions of interest were delineated manually on CT images and then positioned on SPET images. Several attenuation-corrected transaxial SPET slices (thickness 1 cm, spacing 3.5 cm) were reconstructed. Each SPET slice was divided into several 2x2x1 cm(3) elements. Inhomogeneity was assessed by the coefficient of variation (CV) of the pixel counts within these elements (micro-level) and the CV of the total counts of the elements (macro-level). Micro-level CVs in non-smokers varied between 1% and 41%, whereas they were dispersed over a wide range (1%-600%) in emphysematous patients. In seven smokers, the frequency distribution of micro-level CVs was within the normal range, whereas in the other two smokers the values were between the normal range and the range in emphysematous patients. The pooled mean values of micro-level CVs and macro-level CVs in each subject clearly separated the patients from the others. Parametric images of micro-level CV indicated the localisation and severity of ventilation inhomogeneity. We conclude that the present method enables quantification and localisation of regional inhomogeneity in ventilation SPET images.
  •  
36.
  •  
37.
  •  
38.
  •  
39.
  •  
40.
  •  
41.
  • Dewaraja, Yuni K., et al. (författare)
  • Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification
  • 2001
  • Ingår i: European Journal Of Nuclear Medicine. - : Springer Science and Business Media LLC. - 1432-105X .- 0340-6997 .- 1619-7089. ; 28:7, s. 900-906
  • Tidskriftsartikel (refereegranskat)abstract
    • In our clinical iodine-131 single-photon emission tomography (SPET) quantification for radioimmunotherapy, calibration and partial volume correction are based on measurements with phantoms containing spheres to simulate patient tumors even though real tumors are frequently nonspherical. In this study, Monte Carlo simulation was used to evaluate how object shape influences "spill-out" and "spill-in", which are major sources of quantification error associated with the poor spatial resolution of 131I SPET. Objects that varied in shape (spheres, cylinders, and an irregular structure) but were identical in activity and volume were simulated. Iterative reconstruction employed both attenuation and triple-energy-window scatter compensation. VOIs were defined in the reconstructed images both using physical boundaries and using expanded boundaries to allow for the limited resolution. When physical boundaries were used, both spill-out and spill-in were more significant for nonspherical structures than for spherical structures. Over the range of object volumes (50-200 ml) and at all background levels, VOI counts in cylinders were lower than VOI counts in spheres. This underestimation increased with decrease in object size (for the cold background -18% at 200 ml and -39% at 50 ml). It also decreased with increase in background activity because spill-in partially compensated for spill-out. It was shown that with a VOI larger than physical size, the results are independent of object shape and size only in the case of cold background. Activity quantification was carried out using a procedure similar to that used in our clinic. Quantification of nonspherical objects was improved by simple sphere-based partial volume correction, but the error was still large in some cases (for example, -39% for a 50-ml cylinder in a cold background and -35% for a 200-ml irregular structure defined on the basis of a typical tumor outlined on an X-ray computed tomography scan of a patient with non-Hodgkin's lymphoma). Partial volume correction by patient-specific Monte Carlo simulation may provide better quantification accuracy.
  •  
42.
  •  
43.
  •  
44.
  •  
45.
  • Holst, Holger, et al. (författare)
  • An independent evaluation of a new method for automated interpretation of lung scintigrams using artificial neural networks
  • 2001
  • Ingår i: European Journal Of Nuclear Medicine. - : Springer Science and Business Media LLC. - 0340-6997 .- 1619-7089. ; 28:1, s. 33-38
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to evaluate a new automated method for the interpretation of lung perfusion scintigrams using patients from a hospital other than that where the method was developed, and then to compare the performance of the technique against that of experienced physicians. A total of 1,087 scintigrams from patients with suspected pulmonary embolism comprised the training group. The test group consisted of scintigrams from 140 patients collected in a hospital different to that from which the training group had been drawn. An artificial neural network was trained using 18 automatically obtained features from each set of perfusion scintigrams. The image processing techniques included alignment to templates, construction of quotient images based on the perfusion/template images, and finally calculation of features describing segmental perfusion defects in the quotient images. The templates represented lungs of normal size and shape without any pathological changes. The performance of the neural network was compared with that of three experienced physicians who read the same test scintigrams according to the modified PIOPED criteria using, in addition to perfusion images, ventilation images when available and chest radiographs for all patients. Performances were measured as area under the receiver operating characteristic curve. The performance of the neural network evaluated in the test group was 0.88 (95% confidence limits 0.81–0.94). The performance of the three experienced experts was in the range 0.87–0.93 when using the perfusion images, chest radiographs and ventilation images when available. Perfusion scintigrams can be interpreted regarding the diagnosis of pulmonary embolism by the use of an automated method also in a hospital other than that where it was developed. The performance of this method is similar to that of experienced physicians even though the physicians, in addition to perfusion images, also had access to ventilation images for most patients and chest radiographs for all patients. These results show the high potential for the method as a clinical decision support system.
  •  
46.
  •  
47.
  •  
48.
  •  
49.
  •  
50.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-50 av 56

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy