Pharyngeal solid-state manometry catheter movement during swallowing in dysphagic and nondysphagic participants

Olsson, R (författare)
Nilsson, H (författare)
Ekberg, Olle (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
 (creator_code:org_t)
1994
1994
Engelska.
Ingår i: Academic Radiology. - 1878-4046. ; 1:4, s. 339-344
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • RATIONALE AND OBJECTIVES: The movements of the soft palate and the larynx are crucial in pharyngeal manometry because of the potential risk of manometry sensor dislocation. METHODS: Twenty dysphagic patients and 20 nondysphagic volunteers were examined with simultaneous videoradiography and intraluminal pharyngeal solid-state manometry. The movements of the manometric sensors were analyzed from lateral videorecording. RESULTS: Two different types of catheter movement were found. The sensor in the upper esophageal sphincter (UES) could either be lifted cranially during the closure of the soft palate (type 1) or stay unaltered in the sphincter until the beginning of the laryngeal elevation and then follow the sphincter cranially during laryngeal elevation with no previous response to soft palate closure (type 2). Type 1 movement was found in eight of 20 patients but in only one of the 20 volunteers. The resting pressure of the upper esophageal sphincter was significantly higher in type 2 (P = 0.004). Nineteen of the 20 patients with a high resting pressure of the UES (83+ mm Hg) were found to have the type 2 movement. CONCLUSION: High resting pressure in the UES permitted the sphincter to grasp the manometry catheter and caused the sensor to follow the cranial movement during laryngeal elevation. Sensor movement is important during pharyngeal manometry, and sensor dislocation out of the sphincter can be misinterpreted as sphincter relaxation. Simultaneous videoradiography provides control of sensor positioning and allows for correction.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Olsson, R
Nilsson, H
Ekberg, Olle
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Academic Radiolo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy