1.
  • Kamp, A., et al. (författare)
  • A revised compartmental model for biokinetics and dosimetry of 2- F-18 FDG
  • 2023
  • Ingår i: EJNMMI Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundThe aim was to review available biokinetic data, collect own experimental data, and propose an updated compartmental model for 2-[F-18]FDG in the frame of the revision of the ICRP report on dose coefficients for radiopharmaceuticals used in diagnostic nuclear medicine.MethodsThe compartmental model was developed based on published biokinetic data for 2-[F-18]FDG. Additional data on urinary excretion in 23 patients (11 males, 12 females) undergoing whole-body PET/CT examinations were obtained within this study. The unknown biokinetic model parameters were derived using the software SAAM II and verified with a modified version of IDAC-Iodide. Dose coefficients for reference adults were calculated with the programme IDAC-Dose 2.1. A dynamic bladder model was employed for urinary bladder dosimetry.ResultsThe proposed model consists of following compartments: blood, heart wall, brain, liver, lungs, pancreas, spleen, kidneys, urinary bladder content and a generic pool compartment "Other". The latter was introduced to account for 2-[F-18]FDG in body organ and tissues besides the explicitly modelled ones. The model predictions showed a good agreement with experimental data. Urinary bladder wall received the highest absorbed dose coefficient of 7.5E-02 mGy/MBq under the assumption of initial urine volume of 100 ml, first voiding at 45 min p.i. and 3.75 h voiding intervals thereafter. The effective dose coefficient calculated according to the current dosimetry framework of ICRP amounted to 1.7E-02 mSv/MBq, compared to 1.9E-02 mSv/MBq in ICRP Publication 128.ConclusionA compartmental model for 2-[F-18]FDG was proposed and will be used to replace the descriptive biokinetic model of ICRP Publication 128. The revised model and the provided dose coefficients are expected to improve reference dosimetry for patients administered with 2-[F-18]FDG.
  •  
2.
  •  
3.
  •  
4.
  • Siebinga, Hinke, et al. (författare)
  • Predicting [177Lu]Lu-HA-DOTATATE kidney and tumor accumulation based on [68Ga]Ga-HA-DOTATATE diagnostic imaging using semi-physiological population pharmacokinetic modeling
  • 2023
  • Ingår i: EJNMMI Physics. - : Springer. - 2197-7364. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundPrediction of [177Lu]Lu-HA-DOTATATE kidney and tumor uptake based on diagnostic [68Ga]Ga-HA-DOTATATE imaging would be a crucial step for precision dosing of [177Lu]Lu-HA-DOTATATE. In this study, the population pharmacokinetic (PK) differences between [177Lu]Lu-HA-DOTATATE and [68Ga]Ga-HA-DOTATATE were assessed and subsequently [177Lu]Lu-HA-DOTATATE was predicted based on [68Ga]Ga-HA-DOTATATE imaging.MethodsA semi-physiological nonlinear mixed-effects model was developed for [68Ga]Ga-HA-DOTATATE and [177Lu]Lu-HA-DOTATATE, including six compartments (representing blood, spleen, kidney, tumor lesions, other somatostatin receptor expressing organs and a lumped rest compartment). Model parameters were fixed based on a previously developed physiologically based pharmacokinetic model for [68Ga]Ga-HA-DOTATATE. For [177Lu]Lu-HA-DOTATATE, PK parameters were based on literature values or estimated based on scan data (four time points post-injection) from nine patients. Finally, individual [177Lu]Lu-HA-DOTATATE uptake into tumors and kidneys was predicted based on individual [68Ga]Ga-HA-DOTATATE scan data using Bayesian estimates. Predictions were evaluated compared to observed data using a relative prediction error (RPE) for both area under the curve (AUC) and absorbed dose. Lastly, to assess the predictive value of diagnostic imaging to predict therapeutic exposure, individual prediction RPEs (using Bayesian estimation) were compared to those from population predictions (using the population model).ResultsPopulation uptake rate parameters for spleen, kidney and tumors differed by a 0.29-fold (15% relative standard error (RSE)), 0.49-fold (15% RSE) and 1.43-fold (14% RSE), respectively, for [177Lu]Lu-HA-DOTATATE compared to [68Ga]Ga-HA-DOTATATE. Model predictions adequately described observed data in kidney and tumors for both peptides (based on visual inspection of goodness-of-fit plots). Individual predictions of tumor uptake were better (RPE AUC –40 to 28%) compared to kidney predictions (RPE AUC –53 to 41%). Absorbed dose predictions were less predictive for both tumor and kidneys (RPE tumor and kidney –51 to 44% and –58 to 82%, respectively). For most patients, [177Lu]Lu-HA-DOTATATE tumor accumulation predictions based on individual PK parameters estimated from diagnostic imaging outperformed predictions based on population parameters.ConclusionOur semi-physiological PK model indicated clear differences in PK parameters for [68Ga]Ga-HA-DOTATATE and [177Lu]Lu-HA-DOTATATE. Diagnostic images provided additional information to individually predict [177Lu]Lu-HA-DOTATATE tumor uptake compared to using a population approach. In addition, individual predictions indicated that many aspects, apart from PK differences, play a part in predicting [177Lu]Lu-HA-DOTATATE distribution.
  •  
5.
  • Tran-Gia, Johannes, et al. (författare)
  • On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration : a European multi-centre evaluation
  • 2023
  • Ingår i: EJNMMI Physics. - 2197-7364. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. Materials and methods: Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68–107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. Results: As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12–1.5%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. Conclusion: This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.
  •  
6.
  • Wikberg, Emma, et al. (författare)
  • Evaluation of reconstruction methods and image noise levels concerning visual assessment of simulated liver lesions in In-111-octreotide SPECT imaging
  • 2023
  • Ingår i: EJNMMI Physics. - 2197-7364. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Early cancer detection is crucial for patients' survival. The image quality in In-111-octreotide SPECT imaging could be improved by using Monte Carlo (MC)-based reconstruction. The aim of this observational study was to determine the detection rate of simulated liver lesions for MC-based ordered subset expectation maximization (OSEM) reconstruction compared to conventional attenuation-corrected OSEM reconstruction.MethodsThirty-seven SPECT/CT examinations with In-111-octreotide were randomly selected. The inclusion criterion was no liver lesions at the time of examination and for the following 3 years. SPECT images of spheres representing lesions were simulated using MC. The raw data of the spheres were added to the raw data of the established healthy patients in 26 of the examinations, and the remaining 11 examinations were not modified. The images were reconstructed using conventional OSEM reconstruction with attenuation correction and post filtering (fAC OSEM) and MC-based OSEM reconstruction without and with post filtering (MC OSEM and fMC OSEM, respectively). The images were visually and blindly evaluated by a nuclear medicine specialist. The criteria evaluated were liver lesion yes or no, including coordinates if yes, with confidence level 1-3. The percentage of detected lesions and accuracy (percentage of correctly classified cases), as well as tumor-to-normal tissue concentration (TNC) ratios and signal-to-noise ratios (SNRs), were evaluated.ResultsThe detection rates were 30.8% for fAC OSEM, 42.3% for fMC OSEM, and 50.0% for MC OSEM. The accuracies were 45.9% for fAC OSEM, 45.9% for fMC OSEM, and 54.1% for MC OSEM. The number of false positives was higher for fMC and MC OSEM. The observer's confidence level was higher in filtered images than in unfiltered images. TNC ratios were significantly higher, statistically, with MC OSEM and fMC OSEM than with AC OSEM, but SNRs were similar due to higher noise with MC OSEM.ConclusionOne in two lesions were found using MC OSEM versus one in three using conventional reconstruction. TNC ratios were significantly improved, statistically, using MC-based reconstruction, but the noise levels increased and consequently the confidence level of the observer decreased. For further improvements, image noise needs to be suppressed.
  •  
7.
  • Young, Peter N E, et al. (författare)
  • Image-derived input functions from dynamic O-15-water PET scans using penalised reconstruction
  • 2023
  • Ingår i: EJNMMI Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundQuantitative positron emission tomography (PET) scans of the brain typically require arterial blood sampling but this is complicated and logistically challenging. One solution to remove the need for arterial blood sampling is the use of image-derived input functions (IDIFs). Obtaining accurate IDIFs, however, has proved to be challenging, mainly due to the limited resolution of PET. Here, we employ penalised reconstruction alongside iterative thresholding methods and simple partial volume correction methods to produce IDIFs from a single PET scan, and subsequently, compare these to blood-sampled input curves (BSIFs) as ground truth. Retrospectively we used data from sixteen subjects with two dynamic O-15-labelled water PET scans and continuous arterial blood sampling: one baseline scan and another post-administration of acetazolamide.ResultsIDIFs and BSIFs agreed well in terms of the area under the curve of input curves when comparing peaks, tails and peak-to-tail ratios with R-2 values of 0.95, 0.70 and 0.76, respectively. Grey matter cerebral blood flow (CBF) values showed good agreement with an average difference between the BSIF and IDIF CBF values of 2% +/- and a coefficient of variation (CoV) of 7.3%.ConclusionOur results show promising results that a robust IDIF can be produced for dynamic O-15-water PET scans using only the dynamic PET scan images with no need for a corresponding MRI or complex analytical techniques and thereby making routine clinical use of quantitative CBF measurements with O-15-water feasible.
  •  