SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ödkvist Lars) srt2:(1990-1994)"

Sökning: WFRF:(Ödkvist Lars) > (1990-1994)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  • Ledin, Torbjörn, et al. (författare)
  • Chronic toxic encephalopathy investigated using dynamic posturography
  • 1991
  • Ingår i: American Journal of Otolaryngology. - 0196-0709 .- 1532-818X. ; 12:2, s. 96-100
  • Tidskriftsartikel (refereegranskat)abstract
    • Seven male patients previously exposed to industrial solvents and diagnosed with chronic toxic encephalopathy (aged 38 to 69 years; mean age, 56 years) were investigated by dynamic posturography and compared with healthy, age-matched male control patients. Dynamic posturography comprises two phases: a sensory organization (SO) phase, in which the support surface and visual surround are either stable or referenced to the patient's sway, with eyes open or closed, and a movement coordination (MC) phase, in which the platform makes active movements. In SO testing, the patient group showed significantly impaired equilibrium performance compared with the control group in most test conditions. The MC test revealed no differences between groups. A relationship was found between the equilibrium score resulting from SO testing with stable support and visual surround and the sway area of the confidence ellipse elicited 3 years previously by static posturography with eyes open. We conclude that patients with chronic toxic encephalopathy have impaired equilibrium, as demonstrated by dynamic posturography testing.
  •  
5.
  • Möller, Claes, 1950-, et al. (författare)
  • Otoneurological findings in workers exposed to styrene
  • 1990
  • Ingår i: Scandinavian Journal of Work, Environment and Health. - : Scandinavian Journal of Work, Environment and Health. - 0355-3140 .- 1795-990X. ; 16:3, s. 189-194
  • Tidskriftsartikel (refereegranskat)abstract
    • An otoneurological test battery was administered to 18 workers with long-term exposure (6-15 years) to styrene at levels well below the current Swedish limit (110 mg/m3). The results were compared with those of a reference group. Disturbances were found in the central auditory pathways of seven workers. Tests reflecting central processing of impulses from different sensory equilibrium organs were abnormal for 16 workers. The most relevant tests seemed to be static posturography and the rotatory visual suppression test. In the posturography the styrene group had a significantly larger sway area than the reference group. In the visual suppression test, the styrene workers displayed a significantly poorer ability to suppress vestibular nystagmus than the reference group. It was concluded that styrene exposure in industrial environments at moderate or low levels causes central nervous system disturbances which are not always diagnosable with psychometric tests but can be apparent in special otoneurological tests.
  •  
6.
  • Möller, Claes, 1950-, et al. (författare)
  • The plasticity of compensatory eye movements in rotatory tests: 1 : the effect of alertness and eye closure
  • 1990
  • Ingår i: Acta Oto-Laryngologica. - : Informa UK Limited. - 0001-6489 .- 1651-2251. ; 109:1-2, s. 15-24
  • Tidskriftsartikel (refereegranskat)abstract
    • Fifteen voluntary subjects with a mean age of 26 years (17–39), participated in two rotatory experiments. The rotatory test used was sinusoidal harmonic acceleration (SHA) test at frequencies of 0.01–0.32 Hz. Compensatory eye movements were measured by means of EOG. Experiment A included rotation in darkness during alerting tasks (day 1), rotation in darkness with no tasks (day 2) and rotation in darkness during alerting tasks (day 3). In the altertness tests, the gain varied between 0.5 and 0.77. Phase values decreased with increasing frequency. The alertness results between days 1 and 3 did not differ in gain or phase. The gain of day 2 (no tasks) displayed significantly reduced gain at all frequencies, and a more pronounced decrease in phase than in the alertness tests. Experiment B compared testing with eyes open (day 1) and eyes closed (day 2) during alerting tasks. These tests displayed significantly decreased gain at all frequencies with eyes closed compared with eyes open and with more negative phase at 0.08–0.32 Hz with eyes closed. The results indicate a central effect of the alertness level on compensatory eye movements, and the effect of eye closure might be explained by bio-mechanical and possibly even central effects on the eye movements. In low-frequency testing, as short a test time as possible should be used, and due to different alertness levels, the results should be evaluated with great caution.
  •  
7.
  • Tham, Richard, et al. (författare)
  • Vestibulotoxicity of organic solvents
  • 1991
  • Ingår i: Fourth international conference on combined effect of environmental factors. - : Johns Hopkins University. ; , s. 101-105
  • Konferensbidrag (refereegranskat)
  •  
8.
  • Vrethem, Magnus, et al. (författare)
  • Correlation between dynamic posturography, clinical investigation, and neurography in patients with polyneuropathy
  • 1991
  • Ingår i: Journal for Oto-Rhino-Laryngology. - : S. Karger AG. - 0301-1569 .- 1423-0275. ; 53:5, s. 294-298
  • Tidskriftsartikel (refereegranskat)abstract
    • Dynamic posturography (PG) is a new objective method to study functional performance in diseases affecting balance. It measures muscle response latencies and sway angles to standardized alterations of a moveable platform and moveable surroundings. Twenty-eight patients with polyneuropathy (PN) were studied by clinical investigation, vibrametry, neurography, and dynamic PG. The results of dynamic PG and vibrametry were compared with those of 29 healthy controls. In the patients with PN, clinical scores correlated to the latencies of the muscle response when the platform was suddenly moved forward, and to equilibrium performance (sway angles) in dynamic PG test conditions with eyes closed and the platform either stable or ‘sway-referenced’. That is, the platform moves in response to the patient’s anterior-posterior sway, creating a disturbed proprioceptive input to the brain. Clinical scores also correlated to the equilibrium performance when both platform and surroundings were sway-referenced. In conclusion dynamic PG, in addition to clinical investigations and neurophysiology, is a valuable and objective method for estimating the equilibrium performance in patients with PN.
  •  
9.
  •  
10.
  • Ödkvist, Lars, et al. (författare)
  • Rotatory tests
  • 1993
  • Ingår i: NES 1993.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy