Response Regime Studies on Standard Detectors for Decay Time Determination in Phosphor Thermometry

Knappe, Christoph (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Abou Nada, Fahd Jouda (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Lindén, Johannes (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Richter, Mattias (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Aldén, Marcus (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
AIP, 2013
2013
Engelska.
Ingår i: Temperature: Its Measurement and Control in Science and Industry, Vol 8. - : AIP. - 1551-7616 .- 0094-243X. ; 1552, s. 879-884
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • This work compares the extent of linear response regimes from standard time-resolving optical detectors for phosphor thermometry. Different types of Photomultipliers (ordinary and time-gated) as well as an Avalanche Photodiode are tested and compared using the phosphorescent time decay of CdWO4 that ranges from 10 mu s down to a few ns within a temperature span of 290 to 580 K. Effects originating from incipient detector saturation, far from obvious to the operator's eye, are revealed as a change in evaluated phosphorescence decay time. Since the decay time of thermographic phosphors itself is used for temperature determination - systematic temperature errors up to several tens of Kelvins may be introduced by such detector saturation. A detector mapping procedure is suggested in order to identify linear response regions where the decay-to-temperature evaluation can be performed unbiased. Generation of such a library is highly recommended prior to any quantitative measurement attempt. Using this detector library, even signals collected in the partly saturated regime can be corrected to their unbiased value extending the usable detector operating range significantly. Further, the use of an external current-to-voltage amplifier proved useful for most applications in time-based phosphor thermometry helping to limit saturation effects whilst maintaining a reasonable bandwidth and signal outputs.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

thermographic phosphor
laser-induced phosphorescence
lifetime
decay
time
time-resolved
saturation

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy