SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Alcantara Juan M. A.) srt2:(2021)"

Sökning: WFRF:(Alcantara Juan M. A.) > (2021)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Fernandez-Verdejo, Rodrigo, et al. (författare)
  • Deciphering the constrained total energy expenditure model in humans by associating accelerometer-measured physical activity from wrist and hip
  • 2021
  • Ingår i: Scientific Reports. - : Nature Research. - 2045-2322. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The constrained total energy expenditure (TEE) model posits that progressive increases in physical activity (PA) lead to increases in TEE; but after certain PA threshold, TEE plateaus. Then, a compensatory reduction in the expenditure of non-essential activities constrains the TEE. We hypothesized that high PA levels as locomotion associate with a compensatory attenuation in arm movements. We included 209 adults (64% females, mean [SD] age 32.1 [15.0] years) and 105 children (40% females, age 10.0 [1.1] years). Subjects wore, simultaneously, one accelerometer in the non-dominant wrist and another in the hip for >= 4 days. We analyzed the association between wrist-measured (arm movements plus locomotion) and hip-measured PA (locomotion). We also analyzed how the capacity to dissociate arm movements from locomotion influences total PA. In adults, the association between wrist-measured and hip-measured PA was better described by a quadratic than a linear model (Quadratic-R-2=0.54 vs. Linear-R-2=0.52; P=0.003). Above the 80th percentile of hip-measured PA, wrist-measured PA plateaued. In children, there was no evidence that a quadratic model fitted the association between wrist-measured and hip-measured PA better than a linear model (R-2=0.58 in both models, P=0.25). In adults and children, those with the highest capacity to dissociate arm movements from locomotion-i.e. higher arm movements for a given locomotion-reached the highest total PA. We conclude that, in adults, elevated locomotion associates with a compensatory reduction in arm movements (probably non-essential fidgeting) that partially explains the constrained TEE model. Subjects with the lowest arm compensation reach the highest total PA.
  •  
2.
  • Migueles, Jairo Hidalgo, et al. (författare)
  • Calibration and Cross-Validation of Accelerometer Cut-Points to Classify Sedentary Time and Physical Activity from Hip and Non-Dominant and Dominant Wrists in Older Adults
  • 2021
  • Ingår i: Sensors. - : MDPI. - 1424-8220. ; 21:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Accelerometers accuracy for sedentary time (ST) and moderate-to-vigorous physical activity (MVPA) classification depends on accelerometer placement, data processing, activities, and sample characteristics. As intensities differ by age, this study sought to determine intensity cut-points at various wear locations people more than 70 years old. Data from 59 older adults were used for calibration and from 21 independent participants for cross-validation purposes. Participants wore accelerometers on their hip and wrists while performing activities and having their energy expenditure measured with portable calorimetry. ST and MVPA were defined as <= 1.5 metabolic equivalents (METs) and >= 3 METs (1 MET = 2.8 mL/kg/min), respectively. Receiver operator characteristic (ROC) analyses showed fair-to-good accuracy (area under the curve [AUC] = 0.62-0.89). ST cut-points were 7 mg (cross-validation: sensitivity = 0.88, specificity = 0.80) and 1 count/5 s (cross-validation: sensitivity = 0.91, specificity = 0.96) for the hip; 18 mg (cross-validation: sensitivity = 0.86, specificity = 0.86) and 102 counts/5 s (cross-validation: sensitivity = 0.91, specificity = 0.92) for the non-dominant wrist; and 22 mg and 175 counts/5 s (not cross-validated) for the dominant wrist. MVPA cut-points were 14 mg (cross-validation: sensitivity = 0.70, specificity = 0.99) and 54 count/5 s (cross-validation: sensitivity = 1.00, specificity = 0.96) for the hip; 60 mg (cross-validation: sensitivity = 0.83, specificity = 0.99) and 182 counts/5 s (cross-validation: sensitivity = 1.00, specificity = 0.89) for the non-dominant wrist; and 64 mg and 268 counts/5 s (not cross-validated) for the dominant wrist. These cut-points can classify ST and MVPA in older adults from hip- and wrist-worn accelerometers.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy