Cryoballoon versus ...
Cryoballoon versus radiofrequency ablation for atrial fibrillation - a study of outcome and safety based on the ESC-EHRA AF ablation long-term registry and the Swedish catheter ablation registry
-
Mortsell, D. (författare)
-
Arbelo, E. (författare)
-
Dagres, N. (författare)
-
visa fler...
-
Brugada, J. (författare)
-
Trines, S. (författare)
-
Malmborg, H. (författare)
-
- Höglund, Niklas (författare)
- Umeå universitet,Kardiologi
-
Tavazzi, L. (författare)
-
Stabile, G. (författare)
-
Blomstrom Lundqvist, C. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2018-08-28
- 2018
- Engelska.
-
Ingår i: European Heart Journal. - : Oxford University Press. - 0195-668X .- 1522-9645. ; 39, s. 52-52
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: Pulmonary vein isolation (PVI), the standard for atrial fibrillation (AF) ablation, is most commonly applied with radiofrequency (RF) energy, although cryoballoon technology (CRYO) has gained widespread use.Purpose: The aim was to compare the second generation cryoballoon and the irrigated RF energy regarding outcomes and safety.Methods: In total, 4657 patients undergoing their first AF ablation were included; 982 with CRYO and 3675 with RF energy from the Swedish catheter ablation registry and the ESC- EHRA Atrial Fibrillation Ablation Long-Term registry. Primary endpoint was repeat AF ablation. Major secondary endpoints included procedural duration, tachyarrhythmia recurrence (>30 seconds duration) and complication rate.Results: The re-ablation rate after 12 months of follow-up was significantly lower in the CRYO versus the RF group, 7.8% versus 11%, p=0.0041 (Figure 1), while freedom from arrhythmia recurrence did not differ between the groups, 70.2% versus 68.2%, p=0.44. The result was not influenced by AF type and RF lesion sets. In multiple Cox regression analysis, paroxysmal AF patients had significantly lower re-ablation risk after CRYO ablation, hazard ratio 0.56 (p=0.041). Procedural duration was significantly shorter with CRYO than RF, (mean±SD) 133.6±45.2 minutes versus 174.6±58.2 minutes, p<0.001. Complication rates did not differ; 53/982 (5.4%) versus 191/3675 (5.2%), CRYO versus RF, p=0.806.Conclusion: The cryoballoon was superior to conventional RF energy by its lower re-ablation rates and shorter procedure times, irrespective of RFablation lesion set used, and with equal safety, which has important clinical and health economic implications.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)