  • Ferrous sulphate gel dosimetry and MRI for proton beam dose measurements
  • 1999
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 44:8, s. 1983-1996
  • Tidskriftsartikel (refereegranskat)abstract
    • Ferrous sulphate gel dosimetry has the potential for measurement of absorbed dose distributions in proton therapy. The chemical properties of the gel are altered according to the radiation dose and these changes can be evaluated in three dimensions using MRI. The purpose of this work was to investigate the properties of a ferrous gel used with clinical proton beams. The gel was irradiated with both monoenergetic and range-modulated proton beams. It was then evaluated using MRI. The depth dose by means of the 1/T1 distribution was studied and compared with data from a plane-parallel plate ionization chamber. 1/T1 was shown to be proportional to the dose at a mean proton energy of approximately 90 MeV. The dose response was no different from that obtained using photon beams. However, on normalization at the entrance, the relative 1/T1 at the Bragg peak was 15-20% lower than the corresponding ionization chamber data for the monoenergetic proton beam. Better agreement was found for the modulated beam, but with significant differences close to the distal edge of the 1/T1 distribution. The change in sensitivity with depth was explained by means of a linear energy transfer dependence. This property was further studied using Monte Carlo methods.
  •  
2.
  • Bäck, Sven (författare)
  • Implementation of MRI gel dosimetry in radiation therapy
  • 1998
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Gel dosimetry was used together with magnetic resonance imaging (MRI) to measure three-dimensional absorbed dose distributions in radiation therapy. Two different dosimeters were studied: ferrous- and monomer gel, based on the principles of radiation-induced oxidation and polymerisation, respectively. Single clinical electron and photon beams were evaluated and gel dose distributions were mainly within 2% of conventional detector results. The ferrous-gel was also used for clinical proton beams. A decrease in signal per absorbed dose was found close to the end of the range of the protons (15-20%). This effect was explained as a linear energy transfer dependence, further supported with Monte Carlo simulations. A method for analysing and comparing data from treatment planning system (TPS) and gel measurements was developed. The method enables a new pixel by pixel evaluation, isodose comparison and dose volume histogram verification. Two standard clinical radiation therapy procedures were examined using the developed TPS verification method. The treatment regimes included several beams of different radiation qualities. The TPS calculated data were in very good agreement with the dose distribution measured by the ferrous-gel. However, in a beam abutment region, larger dose difference was found. Beam adjustment errors and a minor TPS underestimation of the lateral scatter contribution outside the primary electron beam may explain the discrepancy. The overall uncertainty in the ferrous-gel dose determination was considerably reduced using an optimised MRI acquisition protocol and a new MRI scanner. The relative dose uncertainty was found to be better than 3.3% for all dose levels (95% confidence level). Using the method developed for comparing measured gel data with calculated treatment plans, the gel dosimetry method was proven to be a useful tool for radiation treatment planning verification.
  •  
3.
  • Bäck, Sven, et al. (författare)
  • Improvements in absorbed dose measurements for external radiation therapy using ferrous dosimeter gel and MR imaging (FeMRI)
  • 1998
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 43, s. 261-
  • Tidskriftsartikel (refereegranskat)abstract
    • A ferrous gel, based on ferrous (Fe) sulphate and agarose, was used with a clinical magnetic resonance imaging (MRI) scanner to obtain relative dose distribution data from therapeutic photon and electron beams. The FeMRI gel was scanned using a new MRI acquisition protocol optimized for T1 measurements. Thorough comparisons with silicon semiconductor detector and ionization chamber measurements, as well as with Monte Carlo calculations, were performed in order to quantify the improvements obtained using FeMRI for dose estimations. Most of the relative doses measured with FeMRI were within 2% of the doses measured with other methods. The larger discrepancies (2-4%) found at shallow depths are discussed. The uncertainty in relative dose measurements using FeMRI was significantly improved compared with previously reported results (5-10%, one standard deviation, 1 SD), and is today between 1.6% and 3.3% (depending on dose level, 2 SD). This corresponds to an improvement in the minimum detectable dose (3 SD above background) from approximately 2 Gy to better than 0.6 Gy. The results obtained in this study emphasize the importance of obtaining basic FeMRI dose data before the method is extended to complicated treatment regimes.
  •  