SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Baskaran S) srt2:(2015-2019)"

Sökning: WFRF:(Baskaran S) > (2015-2019)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Arthur, Edmund, et al. (författare)
  • Central Macular Thickness in Diabetic Patients : A Sex-based Analysis
  • 2019
  • Ingår i: Optometry and Vision Science. - : American Academy of Optometry. - 1040-5488 .- 1538-9235. ; 96:4, s. 266-275
  • Tidskriftsartikel (refereegranskat)abstract
    • SIGNIFICANCE The pathological changes in clinically significant diabetic macular edema lead to greater retinal thickening in men than in women. Therefore, male sex should be considered a potential risk factor for identifying individuals with the most severe pathological changes. Understanding this excessive retinal thickening in men may help preserve vision. PURPOSE The purpose of this study was to investigate the sex differences in retinal thickness in diabetic patients. We tested whether men with clinically significant macular edema had even greater central macular thickness than expected from sex differences without significant pathological changes. This study also aimed to determine which retinal layers contribute to abnormal retinal thickness. METHODS From 2047 underserved adult diabetic patients from Alameda County, CA, 142 patients with clinically significant macular edema were identified by EyePACS-certified graders using color fundus images (Canon CR6-45NM). First, central macular thickness from spectral domain optical coherence tomography (iVue; Optovue Inc.) was compared in 21 men versus 21 women without clinically significant macular edema. Then, a planned comparison contrasted the greater values of central macular thickness in men versus women with clinically significant macular edema as compared with those without. Mean retinal thickness and variability of central macular layers were compared in men versus women. RESULTS Men without clinically significant macular edema had a 12-μm greater central macular thickness than did women (245 ± 21.3 and 233 ± 13.4 μm, respectively; t40 = −2.18, P = .04). Men with clinically significant macular edema had a 67-μm greater central macular thickness than did women (383 ± 48.7 and 316 ± 60.4 μm, P < .001); that is, men had 55 μm or more than five times more (t20 = 2.35, P = .02). In men, the outer-nuclear-layer thickness was more variable, F10,10 = 9.34. CONCLUSIONS Underserved diabetic men had thicker retinas than did women, exacerbated by clinically significant macular edema.
  •  
3.
  • Arthur, Edmund, et al. (författare)
  • Individual Retinal Layer Thickness in Diabetic Patients with Clinically Significant Macular Edema : A Gender Based Analysis
  • 2016
  • Konferensbidrag (refereegranskat)abstract
    • Purpose: To compare segmented retinal layer thicknesses between male and female diabetics with clinically significant macular edema (CSME). This study expands our earlier analysis of central macular thickness (CMT) measurements in diabetic males vs. females. Methods: Diabetic retinopathy screening of 2080 diabetics from Alameda County, CA, indicated 142 patients with CSME, as judged by EyePACS certified graders using color fundus images (Canon CR6-45NM). Of the 2080 diabetics, 1784 were imaged with SD-OCT (Optovue iVue). From the 142 patients, we selected 11 males with good fixation, CMT > 300 µm, and no other ocular complications, along with 11 females with the greatest values of CMT while controlling for age, HbA1c and diabetes duration. Manual segmentation of retinal layers using custom software (Mathworks Matlab) of the SD-OCT images of these subjects was done. We analyzed thicknesses for regions 1 deg - 2 deg for nasal and temporal retina in a B-scan centered on the fovea. A 2 X 2 ANOVA probed the differences in thickness for gender, meridian, and their interaction. We also analyzed the central 1 mm of the outer retinal layers, and performed t-tests. Results: Males had significantly thicker nerve fiber layer (NFL) (13.30 ± 2.85 µm) than females (10.13 ± 6.13 µm) and ganglion cell layer-inner plexiform layer (GCL-IPL) (62.54 ± 21.18 µm) than females (48.07 ± 25.91 µm), p < 0.05. There was no effect of meridian and no interaction (p > 0.05). All other layers except the retinal pigment epithelium (RPE) were thicker for males than females even though these were not significant (p > 0.05). There were no significant differences for the layers of the outer retina, which were highly variable and distorted by cysts. Conclusion: Outside the fovea, NFL and GCL-IPL thicknesses were significantly higher in males than females.
  •  
4.
  • Elsner, Ann E., et al. (författare)
  • Underserved diabetic patients with refractive errors insufficient to lead to seeking eyecare
  • 2015
  • Konferensbidrag (refereegranskat)abstract
    • Purpose: The increase in prevalence of diabetes is anticipated to increase the numbers of patients needing eye examinations. For our Phase II SBIR data, we reported that for > 2000 underserved diabetic patients in Alameda County, California, > 60% of patients reported no eye examination for at least 3 years despite that free photo diabetic retinopathy screenings were offered with follow on examination and eyecare. If eye screening for diabetic patients is not mandated, it becomes the responsibility of the patient or their primary care physician or endocrinologist to understand and act on the need for eye examinations. Methods: From the Alameda Health system of clinics, 197 diabetic patients agreed to be photoscreened for diabetic retinopathy. Our sample was enriched to have an increased probability of eye complications; thus, 26% had no apparent diabetic retinopathy; 38%, 17% and 4% had mild, moderate and severe non-proliferative diabetic retinopathy; and 13% had proliferative diabetic retinopathy. Of the 141 patients with diabetic retinopathy, 29% had bilateral CSME. Of the 132 diabetic patients (67 males and 65 females) returning for full eye exams, 52% were Hispanic, 21% African American, 14% Asian, and 8% NonHispanic Caucasian and Other, with an average age of 58.1 ± 9.4 years. Refractive errors were defined as spherical equivalent (SE) refraction, calculated as the spherical power plus one-half of the cylindrical power. Results: The overall mean spherical equivalent refraction M was −0.16 ± 1.50 D in the right eye (−6.0 D to +3.0 D) and +0.14 ± 1.35 D (−7.0 D to +4.0 D) in the left eye. Out of 132 patients, eight patients (6.1%) had visual acuity worse than 0.3 logMAR in both eyes. The right eyes of four patients and left eyes of eight patients had visual acuity worse than 0.3 logMAR, with fellow eyes having normal visual acuity. Conclusions: In a sample of largely minority, working age adults, there was very little refractive error and relatively good visual acuity when refracted, despite diabetic retinopathy or diabetic macular edema. Thus, working age diabetic patients may not regularly seek eye care for spectacle correction that would lead to the detection of diabetic retinopathy or diabetic macular edema.
  •  
5.
  • Hernandez-Moreno, Laura, et al. (författare)
  • Absent Foveal Pit, Also Known as Fovea Plana, in a Child without Associated Ocular or Systemic Findings
  • 2018
  • Ingår i: Case Reports in Ophthalmological Medicine. - : Hindawi Publishing Corporation. - 2090-6722 .- 2090-6730. ; , s. 1-5
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this report is to describe a case of bilateral foveal hypoplasia in the absence of other ophthalmological or systemic manifestations. We characterize the case of a 9-year-old Caucasian male who underwent full ophthalmologic examination, including functional measures of vision and structural measurements of the eye. Best corrected visual acuity was 0.50 logMAR in the right eye and 0.40 logMAR in the left eye. Ophthalmoscopy revealed a lack of foveal reflex that was further investigated. Optical coherence tomography (OCT) confirmed the absence of foveal depression (pit). OCT images demonstrated the abnormal structure of retina in a region in which we expected a fovea; these findings were decisive to determine the cause of reduced acuity in the child.
  •  
6.
  • Ingling, Allen W, et al. (författare)
  • Fixation stability readily obtained from confocal color fundus imaging
  • 2015
  • Ingår i: Investigative Ophthalmology and Visual Science. - 0146-0404 .- 1552-5783. ; 56:7, s. 515-515
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeStabile fixation underpins most visual tasks such as reading, and is important for accurate assessment of visual function and treatment. Retinal imaging instruments average images over time to improve the signal to noise ratio, discarding useful eye movement data. We determined whether the frame-to-frame motion of the retina during non-mydriatic color fundus imaging could provide fixation stability measures, e.g. Bivariate Contour Ellipse Area (BCEA). MethodsNon-mydriatic color fundus images were acquired using the Digital Light Ophthalmoscope (DLO). Twenty subjects with varied fundus pigmentation were tested without mydriasis. The DLO uses a digital light projector with LED light sources to provide the illumination for both confocal imaging and fixation stimuli. The DLO projects a series of lines across the fundus that is synchronized to the 2D CMOS sensor, providing high contrast confocal imaging. Monochromatic 40 deg images were acquired with alternating red and green LED illumination at 14.3 Hz and overlayed to present a pseudo-color image to the operator in real time. To reduce pupil constriction and patient discomfort, the green LED was long-pass filtered with a 570 nm filter. A 1.5mm entrance pupil and time-averaged power of <30 uW were used. Images were aligned automatically with custom software (MATLAB) using cross-correlation and 2D translation. A canvas of twice the image size was used to allow image alignment despite moderate eye movements. Blinks and large saccades were discarded and BCEA was computed. ResultsThe image alignment algorithm successfully aligned nearly all the frames, rejecting 3.7%, and allowing fixation stability to be computed from color fundus image data. The BCEA for 1 standard deviation was 2.97 log minarc2 for all subjects and both the red and yellow-orange illumination. There was no difference between the BCEA for red or yellow-orange illumination (t = .86). ConclusionsThe color DLO records sufficiently high quality images to reliably calculate measures of fixation stability. Despite recruiting an especially challenging population that included dark fundi, small pupils, high refractive errors, and media issues, we achieved success in all subjects tested to date.
  •  
7.
  • Muller, Matthew S, et al. (författare)
  • Non-mydriatic color fundus imaging with the Digital Light Ophthalmoscope
  • 2015
  • Konferensbidrag (refereegranskat)abstract
    • Purpose To provide non-mydriatic confocal color fundus imaging of sufficient quality for screening for diabetic retinopathy despite dark fundus pigmentation, small pupil, high refractive error, or other anterior segment issues. MethodsNon-mydriatic color fundus images of 34 volunteers (aged 39.2 ± 13.2 yr) were acquired using the Digital Light Ophthalmoscope (DLO). 10 subjects had dark fundi and/or high refractive errors, as well as other anterior segment issues. Unique to retinal cameras, the Digital Light Ophthalmoscope (DLO) uses a digital light projector with LED light sources to provide the illumination for both confocal imaging and fixation stimuli. The DLO projects a series of lines across the fundus that is synchronized to the electronic rolling shutter read-out on a 2D CMOS sensor, providing high contrast confocal imaging that is highly customizable through software. Monochromatic 40 deg field images were acquired with alternating red and green LED illumination at 14.3 Hz and overlayed to present a pseudo-color image to the operator in real time. To reduce pupil constriction and patient discomfort while maintaining strong blood absorption, the green illumination was long-pass filtered with a 570 nm filter, and a 1.5mm entrance pupil and time-averaged power of <30 uW was used. ResultsThe DLO provided gradable quality non-mydriatic fundus images in all tested subjects, including those with dark fundi or pupils < 2 mm, as judged by an EyePACS certified grader. The use of long pass filters in the green LED permitted high contrast, non-mydriatic images with illumination wavelengths >570 nm and limited pupil constriction. Retinal vessels at the 4th branch or smaller, as well as neovascularization in diabetic retinopathy, could be seen. Hyperpigmentation was clearly seen both peripherally as bear tracks and centrally at the posterior pole. The aperture width and color balance can be adjusted to provide high contrast and yet relatively uniform and natural color across the image. ConclusionsThe DLO provides confocal color fundus images in real time without the use of short (< 570nm) wavelength light. Despite recruiting an especially challenging population that included dark fundi, small pupils, high refractive errors, and media issues, we achieved a 100% success rate in obtaining gradable images for screening.
  •  
8.
  • Muller, Matthew S., et al. (författare)
  • Non-mydriatic confocal retinal imaging using a digital light projector
  • 2015
  • Ingår i: <em>Proceedings of SPIE, vol</em> 9376. - : SPIE - International Society for Optical Engineering. ; , s. 93760E-1-93760E-10
  • Konferensbidrag (refereegranskat)abstract
    • A digital light projector is implemented as an integrated illumination source and scanning element in a confocal nonmydriatic retinal camera, the Digital Light Ophthalmoscope (DLO). To simulate scanning, a series of illumination lines are rapidly projected on the retina. The backscattered light is imaged onto a 2-dimensional rolling shutter CMOS sensor. By temporally and spatially overlapping the illumination lines with the rolling shutter, confocal imaging is achieved. This approach enables a low cost, flexible, and robust design with a small footprint. The 3rd generation DLO technical design is presented, using a DLP LightCrafter 4500 and USB3.0 CMOS sensor. Specific improvements over previous work include the use of yellow illumination, filtered from the broad green LED spectrum, to obtain strong blood absorption and high contrast images while reducing pupil constriction and patient discomfort.
  •  
9.
  • Schmidt, Linnéa, et al. (författare)
  • Case-specific potentiation of glioblastoma drugs by pterostilbene
  • 2016
  • Ingår i: Oncotarget. - : Impact Journals, LLC. - 1949-2553. ; 7:45, s. 73200-73215
  • Tidskriftsartikel (refereegranskat)abstract
    • Glioblastoma multiforme (GBM, astrocytoma grade IV) is the most common malignant primary brain tumor in adults. Addressing the shortage of effective treatment options for this cancer, we explored repurposing of existing drugs into combinations with potent activity against GBM cells. We report that the phytoalexin pterostilbene is a potentiator of two drugs with previously reported anti-GBM activity, the EGFR inhibitor gefitinib and the antidepressant sertraline. Combinations of either of these two compounds with pterostilbene suppress cell growth, viability, sphere formation and inhibit migration in tumor GBM cell (GC) cultures. The potentiating effect of pterostilbene was observed to a varying degree across a panel of 41 patient-derived GCs, and correlated in a case specific manner with the presence of missense mutation of EGFR and PIK3CA and a focal deletion of the chromosomal region 1p32. We identify pterostilbene-induced cell cycle arrest, synergistic inhibition of MAPK activity and induction of Thioredoxin interacting protein (TXNIP) as possible mechanisms behind pterostilbene's effect. Our results highlight a nontoxic stilbenoid compound as a modulator of anticancer drug response, and indicate that pterostilbene might be used to modulate two anticancer compounds in well-defined sets of GBM patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy