SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brännmark M) srt2:(2010-2014)"

Sökning: WFRF:(Brännmark M) > (2010-2014)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Asif, Muhammad H, et al. (författare)
  • Functionalised ZnO-nanorod-based selective electrochemical sensor for intracellular glucose
  • 2010
  • Ingår i: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 25:10, s. 2205-2211
  • Tidskriftsartikel (refereegranskat)abstract
    • In this article, we report a functionalised ZnO-nanorod-based selective electrochemical sensor for intracellular glucose. To adjust the sensor for intracellular glucose measurements, we grew hexagonal ZnO nanorods on the tip of a silver-covered borosilicate glass capillary (0.7 mu m diameter) and coated them with the enzyme glucose oxidase. The enzyme-coated ZnO nanorods exhibited a glucose-dependent electrochemical potential difference versus an Ag/AgCl reference microelectrode. The potential difference was linear over the concentration range of interest (0.5-1000 mu M). The measured glucose concentration in human adipocytes or frog oocytes using our ZnO-nanorod sensor was consistent with values of glucose concentration reported in the literature; furthermore, the sensor was able to show that insulin increased the intracellular glucose concentration. This nanoelectrode device demonstrates a simple technique to measure intracellular glucose concentration. (C) 2010 Elsevier B.V. All rights reserved.
  •  
2.
  •  
3.
  •  
4.
  • Fulati, Alimujiang, 1981-, et al. (författare)
  • An intracellular glucose biosensor based on nanoflake ZnO
  • 2010
  • Ingår i: Sensors and actuators. B, Chemical. - : Elsevier. - 0925-4005 .- 1873-3077. ; 150:2, s. 673-680
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • In this study, an improved potentiometric intracellular glucose biosensor was fabricated with immobilization of glucose oxidase on a ZnO nanoporous material. The ZnO nanoporous material with a wall thickness around 200 nm was grown on the tip of a borosilicate glass capillary and used as a selective intracellular glucose sensor for the measurement of glucose concentrations in human adipocytes and frog oocytes. The results showed a fast response within 4 s and a linear glucosedependent electrochemical response over a wide range of glucose concentration (500 nM-10 mM). The measurements of intracellular glucose concentrations with our biosensor were consistent with the values of intracellular glucose concentrations reported in the literature. The sensor also demonstrated its capability by detecting an increase in the intracellular glucose concentration induced by insulin. We found that the ZnO nanoporous material provides sensitivity as high as 1.8 times higher than that obtained using ZnO nanorods under the same conditions. Moreover, the fabrication method in our experiment is simple and the excellent performance of the developed nanosensor in sensitivity, stability, selectivity, reproducibility and anti-interference was achieved. All these advantageous features of this intracellular glucose biosensor based on functionalised ZnO nanoporous material compared to ZnO nanorods demonstrate a promising way of enhancing glucose biosensor performance to measure reliable intracellular glucose concentrations within single living cells.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy