SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brunkwall J) srt2:(2010-2014)"

Sökning: WFRF:(Brunkwall J) > (2010-2014)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brunkwall, J., et al. (författare)
  • Endovascular Repair of Acute Uncomplicated Aortic Type B Dissection Promotes Aortic Remodelling: 1 Year Results of the ADSORB Trial
  • 2014
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 48:3, s. 285-291
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Uncomplicated acute type B aortic dissection (AD) treated conservatively has a 10% 30-day mortality and up to 25% need intervention within 4 years. In complicated AD, stent grafts have been encouraging. The aim of the present prospective randomised trial was to compare best medical treatment (BMT) with BMT and Gore TAG stent graft in patients with uncomplicated AD. The primary endpoint was a combination of incomplete/no false lumen thrombosis, aortic dilatation, or aortic rupture at 1 year. Methods: The AD history had to be less than 14 days, and exclusion criteria were rupture, impending rupture, malperfusion. Of the 61 patients randomised, 80% were DeBakey type IIIB. Results: Thirty-one patients were randomised to the BMT group and 30 to the BMT+TAG group. Mean age was 63 years for both groups. The left subclavian artery was completely covered in 47% and in part in 17% of the cases. During the first 30 days, no deaths occurred in either group, but there were three crossovers from the BMT to the BMT TAG group, all due to progression of disease within 1 week. There were two withdrawals from the BMT+TAG group. At the 1-year follow up there had been another two failures in the BMT group: one malperfusion and one aneurysm formation (p = .056 for all). One death occurred in the BMT TAG group. For the overall endpoint BMT+TAG was significantly different from BMT only (p < .001). Incomplete false lumen thrombosis, was found in 13 (43%) of the TAG+BMT group and 30 (97%) of the BMT group (p < .001). The false lumen reduced in size in the BMT+TAG group (p < .001) whereas in the BMT group it increased. The true lumen increased in the BMT TAG (p < .001) whereas in the BMT group it remained unchanged. The overall transverse diameter was the same at the beginning and after 1 year in the BMT group (42.1 mm), but in the BMT+TAG it decreased (38.8 mm; p = .062). Conclusions: Uncomplicated AD can be safely treated with the Gore TAG device. Remodelling with thrombosis of the false lumen and reduction of its diameter is induced by the stent graft, but long term results are needed. (C) 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
  •  
2.
  • Verhoeven, E. L. G., et al. (författare)
  • Real-world Performance of the New C3 Gore Excluder Stent-Graft : 1-year Results from the European C3 Module of the Global Registry for Endovascular Aortic Treatment (GREAT)
  • 2014
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1078-5884 .- 1532-2165. ; 48:2, s. 131-137
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) provides "real-world" outcomes for the new C3 Gore Excluder stent-graft, and evaluates the new deployment mechanism. This report presents the 1-year results from 400 patients enrolled in this registry. Methods: Between August 2010 and December 2012, 400 patients (86.8% male, mean age 73.9 +/- 7.8 years) from 13 European sites were enrolled in this registry. Patient demographics, treatment indication, case planning, operative details including repositioning and technical results, and clinical outcome were analyzed. Results: Technical success was achieved in 396/400 (99%) patients. Two patients needed intraoperative open conversion, one for iliac rupture, the second because the stent-graft was pulled down during a cross-over catheterization in an angulated anatomy. Two patients required an unplanned chimney renal stent to treat partial coverage of the left renal artery because of upward displacement of the stent-graft. Graft repositioning occurred in 192/399 (48.1%) patients, most frequently for level readjustment with regard to the renal arteries, and less commonly for contralateral gate reorientation. Final intended position of the stent-graft below the renal arteries was achieved in 96.2% of patients. Thirty-day mortality was two (0.5%) patients. Early reintervention (<= 30 days) was required in two (0.5%) patients. Mean follow-up duration was 15.9 +/- 8.8 months (range 0-37 months). Late reintervention (>30 days) was required in 26 (6.5%) patients. Estimated freedom from reintervention at 1 year was 95.2% (95% CI 92.3-97%), and at 2 years 91.5% (95% CI 86.8-94.5%). Estimated patient survival at 1 year was 96% (95% CI 93.3-97.6%) and at 2 years 90.6% (95% CI 85.6-93.9%). Conclusions: Early real-world experience shows that the new C3 delivery system offers advantages in terms of device repositioning resulting in high deployment accuracy. Longer follow-up is required to confirm that this high deployment accuracy results in improved long-term durability.
  •  
3.
  • Breuer, Silke, et al. (författare)
  • Introduction of embryonic stem cells into vein grafts reduces intimal hyperplasia in mice.
  • 2014
  • Ingår i: The Journal of cardiovascular surgery. - 0021-9509. ; 55:2, s. 235-46
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: Atherosclerosis with its cardiovascular events including cardiac and peripheral ischemia represents the main cause of death in the developed countries. Although interventional treatments like percutaneous transluminal angioplasty (PTA) or stents are increasingly applied for the treatment of peripheral arterial disease, they are not always technically applicable or durable and bypass surgery is needed. Compared to synthetic grafts, vein grafts show a better patency especially when used for the lower leg as well as a lower risk for infection compared to synthetic grafts. Still the long-term patency rates are unsatisfactory due to accelerated intimal hyperplasia, a thickening of the vessel wall. The aim of this study was to elucidate, if the implantation of embryonic stem cells into vein grafts can reduce the development of intimal hyperplasia in a mouse in vivo model. Methods: In this study we implanted LacZ-tagged (ROSA26) murine embryonic stem cells into decellularized vein grafts. Control groups were: 1) untreated veins; 2) decellularized veins; 3) decellularized veins with gel and plastic film; and 4) decellularized veins with smooth muscle cells in gel surrounded by plastic film. Six weeks after insertion into the carotid artery of mice, the grafts were excised and analyzed immunohistochemically, morphologically, and by x-gal staining and compared to the control groups. The Mann-Whitney-U test was used to compare groups. Statistical significance was indicated by a value of P<0.05. Results: Decellularized veins with implanted stem cells showed significantly less intimal thickening compared to all control groups (intimal hyperplasia vs. luminal circumference mean±SD 7.3±3.5 µm, median 8 µm). The control groups: 1) untreated veins (60.3±25.5 µm, median 58.5 µm); 2) decellularized veins (53.9±22.4 µm, median 48.4 µm); 3) decellularized veins with gel and plastic film (70.6±22.4 µm, median 72.6 µm); and 4) decellularized veins with smooth muscle cells in gel surrounded by plastic film (73.5±18.1 µm, median 73.6 µm) all showed the same high degree of intimal hyperplasia. Conclusion: This study demonstrates that embryonic stem cells have a therapeutic competence to favourably modulate intimal hyperplasia in vivo.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy