SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Cadenas Sanchez Cristina)
 

Sökning: WFRF:(Cadenas Sanchez Cristina) > (2021) > Calibration and Cro...

Calibration and Cross-Validation of Accelerometer Cut-Points to Classify Sedentary Time and Physical Activity from Hip and Non-Dominant and Dominant Wrists in Older Adults

Migueles, Jairo Hidalgo (författare)
Linköpings universitet,Avdelningen för samhälle och hälsa,Medicinska fakulteten,Univ Granada, Spain
Cadenas-Sanchez, Cristina (författare)
Univ Granada, Spain; Univ Publ Navarra, Spain
Alcantara, Juan M. A. (författare)
Univ Granada, Spain
visa fler...
Leal-Martin, Javier (författare)
Univ Castilla La Mancha, Spain; CIBER Frailty & Hlth Aging CIBERFES, Spain
Manas, Asier (författare)
Univ Castilla La Mancha, Spain; CIBER Frailty & Hlth Aging CIBERFES, Spain
Ara, Ignacio (författare)
Univ Castilla La Mancha, Spain; CIBER Frailty & Hlth Aging CIBERFES, Spain
Glynn, Nancy W. (författare)
Univ Pittsburgh, PA 15260 USA
Shiroma, Eric J. (författare)
NIH, MD 20892 USA
visa färre...
 (creator_code:org_t)
2021-05-11
2021
Engelska.
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 21:10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Accelerometers accuracy for sedentary time (ST) and moderate-to-vigorous physical activity (MVPA) classification depends on accelerometer placement, data processing, activities, and sample characteristics. As intensities differ by age, this study sought to determine intensity cut-points at various wear locations people more than 70 years old. Data from 59 older adults were used for calibration and from 21 independent participants for cross-validation purposes. Participants wore accelerometers on their hip and wrists while performing activities and having their energy expenditure measured with portable calorimetry. ST and MVPA were defined as <= 1.5 metabolic equivalents (METs) and >= 3 METs (1 MET = 2.8 mL/kg/min), respectively. Receiver operator characteristic (ROC) analyses showed fair-to-good accuracy (area under the curve [AUC] = 0.62-0.89). ST cut-points were 7 mg (cross-validation: sensitivity = 0.88, specificity = 0.80) and 1 count/5 s (cross-validation: sensitivity = 0.91, specificity = 0.96) for the hip; 18 mg (cross-validation: sensitivity = 0.86, specificity = 0.86) and 102 counts/5 s (cross-validation: sensitivity = 0.91, specificity = 0.92) for the non-dominant wrist; and 22 mg and 175 counts/5 s (not cross-validated) for the dominant wrist. MVPA cut-points were 14 mg (cross-validation: sensitivity = 0.70, specificity = 0.99) and 54 count/5 s (cross-validation: sensitivity = 1.00, specificity = 0.96) for the hip; 60 mg (cross-validation: sensitivity = 0.83, specificity = 0.99) and 182 counts/5 s (cross-validation: sensitivity = 1.00, specificity = 0.89) for the non-dominant wrist; and 64 mg and 268 counts/5 s (not cross-validated) for the dominant wrist. These cut-points can classify ST and MVPA in older adults from hip- and wrist-worn accelerometers.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Nyckelord

sedentary behavior; movement; light intensity; exercise; sitting; elderly; counts; ENMO

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy