1.
  • Svalkvist, Angelica, et al. (författare)
  • Investigation of the effect of varying scatter-to-primary ratios on nodule contrast in chest tomosynthesis
  • 2011
  • Ingår i: Medical Imaging 2011. - : SPIE - International Society for Optical Engineering. - 9780819485038 ; 7961
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The primary aim of the present work was to analyze the effects of varying scatter-to-primary ratios on the appearance of simulated nodules in chest tomosynthesis section images. Monte Carlo simulations of the chest tomosynthesis system GE Definium 8000 VolumeRAD (GE Healthcare, Chalfont St. Giles, UK) were used to investigate the variation of scatter-to-primary ratios between different angular projections. The simulations were based on a voxel phantom created from CT images of an anthropomorphic chest phantom. An artificial nodule was inserted at 80 different positions in the simulated phantom images, using five different approaches for the scatter-to-primary ratios in the insertion process. One approach included individual determination of the scatter-to primary-ratio for each projection image and nodule location, while the other four approaches were using mean value, median value and zero degree projection value of the scatter-to-primary ratios at each nodule position as well as using a constant scatter-to-primary ratio of 0.5 for all nodule positions. The results indicate that the scatter-to-primary ratios vary up to a factor of 10 between the different angular tomosynthesis projections (±15°). However, the error in the resulting nodule contrast introduced by not taking all variations into account is in general smaller than 10 %.
  •  
2.
  •  
3.
  • Ullman, Gustaf, et al. (författare)
  • A Monte Carlo-based model for simulation of digital chest tomosynthesis
  • 2010
  • Ingår i: Radiation Protection Dosimetry. - Oxford : Oxford University Press. - 0144-8420 .- 1742-3406. ; 139:1-3, s. 159-163
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this work was to calculate synthetic digital chest tomosynthesis projections using a computer simulation model based on the Monte Carlo method. An anthropomorphic chest phantom was scanned in a computed tomography scanner, segmented and included in the computer model to allow for simulation of realistic high-resolution X-ray images. The input parameters to the model were adapted to correspond to the VolumeRAD chest tomosynthesis system from GE Healthcare. Sixty tomosynthesis projections were calculated with projection angles ranging from +15 to −15°. The images from primary photons were calculated using an analytical model of the anti-scatter grid and a pre-calculated detector response function. The contributions from scattered photons were calculated using an in-house Monte Carlo-based model employing a number of variance reduction techniques such as the collision density estimator. Tomographic section images were reconstructed by transferring the simulated projections into the VolumeRAD system. The reconstruction was performed for three types of images using: (i) noise-free primary projections, (ii) primary projections including contributions from scattered photons and (iii) projections as in (ii) with added correlated noise. The simulated section images were compared with corresponding section images from projections taken with the real, anthropomorphic phantom from which the digital voxel phantom was originally created. The present article describes a work in progress aiming towards developing a model intended for optimisation of chest tomosynthesis, allowing for simulation of both existing and future chest tomosynthesis systems.
  •  