SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Debevec Tadej)
 

Sökning: WFRF:(Debevec Tadej) > (2021) > Reliability and Val...

Reliability and Validity of the CORE Sensor to Assess Core Body Temperature during Cycling Exercise

Verdel, Nina (författare)
Mittuniversitetet,Institutionen för hälsovetenskap,Swedish Winter Sports Research Centre, Mid Sweden University, 83125 Östersund, Sweden
Podlogar, Tim (författare)
Faculty of Health Sciences, University of Primorska, 6310 Izola, Slovenia; Department of Automation, Biocybernetics, and Robotics, Jozef Stefan Institute, 1000 Ljubljana, Slovenia; Human Performance Centre, 1000 Ljubljana, Slovenia
Ciuha, Urša (författare)
Department of Automation, Biocybernetics, and Robotics, Jozef Stefan Institute, 1000 Ljubljana, Slovenia
visa fler...
Holmberg, Hans-Christer, 1958- (författare)
Luleå tekniska universitet,Hälsa, medicin och rehabilitering,Luleå University of Technology
Debevec, Tadej (författare)
Department of Automation, Biocybernetics, and Robotics, Jozef Stefan Institute, 1000 Ljubljana, Slovenia; Faculty of Sport, University of Ljubljana, 1000 Ljubljana, Slovenia
Supej, Matej (författare)
Mittuniversitetet,Institutionen för hälsovetenskap,Swedish Winter Sports Research Centre, Mid Sweden University, 83125 Östersund, Sweden; Faculty of Sport, University of Ljubljana, 1000 Ljubljana, Slovenia
visa färre...
 (creator_code:org_t)
2021-09-03
2021
Engelska.
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 21:17
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Monitoring core body temperature (Tc) during training and competitions, especially in a hot environment, can help enhance an athlete’s performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of Tc would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rümlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 °C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 °C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (Trec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 °C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with Trec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of ≤0.3 °C. In conclusion, the results obtained do not support the manufacturer’s claim that the CORE sensor provides a valid measure of core body temperature.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Nyckelord

validity
reliability
core body temperature
rectal temperature
CORE sensor
cycling
non-invasive
Physiotherapy
Fysioterapi
Centre - Swedish Sports Technology and Performance Research Centre (SPORTC)
Centrumbildning - Swedish Sports Technology and Performance Research Centre (SPORTC)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy